background image

40 AMP SMART

FULLY AUTOMATIC BATTERY CHARGER

INSTRUCTION MANUAL

Thank you for choosing Black & Decker!

Go to www.BlackandDecker.com/NewOwner

to register your new product 

Catalog Number BC40EB

BEFORE RETURNING THIS PRODUCT

FOR ANY REASON PLEASE CALL

1-800-544-6986

BEFORE YOU CALL, HAVE THE CATALOG No, AND DATE CODE 

AVAILABLE. IN MOST CASES, A 

BLACK & DECKER

REPRESENTATIVE

CAN RESOLVE THE PROBLEM OVER THE PHONE. IF YOU HAVE A

SUGGESTION OR COMMENT, GIVE US A CALL. YOUR FEEDBACK IS 

VITAL TO BLACK & DECKER.

SAVE THIS MANUAL FOR FUTURE REFERENCE.

Cat. # BC40EB

Form # 90516444

May ’07 

Copyright © 2007 Black & Decker

Printed in China

BC40EB_ManualEN_051707.qxp  6/4/07  2:54 PM  Page i

Содержание BC25EB

Страница 1: ...NG THIS PRODUCT FOR ANY REASON PLEASE CALL 1 800 544 6986 BEFORE YOU CALL HAVE THE CATALOG No AND DATE CODE AVAILABLE IN MOST CASES A BLACK DECKER REPRESENTATIVE CAN RESOLVE THE PROBLEM OVER THE PHONE IF YOU HAVE A SUGGESTION OR COMMENT GIVE US A CALL YOUR FEEDBACK IS VITAL TO BLACK DECKER SAVE THIS MANUAL FOR FUTURE REFERENCE Cat BC40EB Form 90516444 May 07 Copyright 2007 Black Decker Printed in ...

Страница 2: ...LT CIRCUIT INTERRUPTER GFCI protection should be provided on the circuits or outlets to be used Receptacles are available having built in GFCI protection and may be used for this measure of safety USE OF ACCESSORIES AND ATTACHMENTS The use of any accessory or attachment not recommended for use with this appliance could be hazardous Note Refer to the accessory section of this manual for further det...

Страница 3: ...operate unit with damaged cord or plug or if the unit has received a sharp blow been dropped or otherwise damaged in any way Do not disassemble the unit take it to a qualified service technician when service or repair is required Incorrect reassembly may result in a risk of electric shock or fire and will void warranty Use of an attachment not supplied recommended or sold by manufacturer specifica...

Страница 4: ...cian Improper connection can result in a risk of an electric shock Preparing to Charge 1 Determine voltage of battery to be charged by referring to the vehicle manual 2 it is necessary to remove battery from vehicle to charge or to clean terminals always remove grounded terminal from battery first Make sure all accessories in the vehicle are off so as not to cause an arc 3 Clean battery terminals ...

Страница 5: ...d POS P or red 4 Stand as far back from the battery as possible and do not face battery when making final connection 5 Carefully connect the NEGATIVE BLACK charger clamp to the free end of the battery cable connected to the negative terminal 6 Set the charge rate to appropriate setting according to battery size 7 When disconnecting charger always do so in reverse sequence of connecting procedure a...

Страница 6: ...ic Temperature Compensation Battery type selection Digital diagnostics Alternator voltage and battery voltage check Digital display shows charge rate operating mode fault codes and FUL when charged 1 minute engine start 3 stage high frequency switch mode automatic rapid charging Spark resistant reverse polarity and short circuit protection for user Built in battery reconditioning desulfate Lightwe...

Страница 7: ... a battery to maintain its charge over long periods of non use If there is any loss of power to the charger once power is restored charger will automatically return to the default settings Battery selector type would be gel Battery Voltage lights when battery voltage is displayed Alternator Good lights when load or no load checks show the alternator is keeping up with the electrical load Equalize ...

Страница 8: ... display just shows F03 then the battery will not charge Charger occasionally sounds a beep and displays 0 0 during self test or charging stage changes 3 Pressing the 4 10 20 40 AMP button again advances charging rate to 10 amps Pressing once more advances charging rate to 20 amps and again to 40 amps Pressing the button again will turn OFF the charger output and the Display will show 000 This sel...

Страница 9: ...5 2 7v per cell depending on ambient temperature it will automatically adjust 13 The WET LED flashes while the charger is in equalize mode 14 The digital readout will show FUL when the equalization process is complete Engine Start The Engine Start function can supply 110 amps for engine starting 1 Set the 4 10 20 40 AMPS button to 40 amp mode and immediately press the 110A button switch to activat...

Страница 10: ...failure or possibly bad connections between the battery and alternator and or ground Notes BATTERY VOLTAGE button is disabled in Alternator Check mode F07 may display because someone has added a number of accessory loads on the charging system thereby increasing current demand from the alternator MAKE SURE THAT THE ALTERNATOR IS RATED TO SUPPORT THE APPLICATION This check may not be accurate for e...

Страница 11: ...nit to cool for 30 minutes and reconnect Make sure there is ample ventilation before resuming operation F06 Reverse Polarity The connections to the battery s positive and negative terminals are incorrect Follow the steps outlined in Important Safety Instructions at the front of this manual to disconnect AC cord and clamps and reconnect to battery with correct polarity F07 Alternator Voltage Altern...

Страница 12: ...pecific legal rights and you may have other rights which vary from state to state or province to province Should you have any questions contact the manager of your nearest Black Decker Service Center This product is not intended for commercial use FREE WARNING LABEL REPLACEMENT If your warning labels become illegible or are missing call 1 800 544 6986 for a free replacement SPECIFICATIONS Input 12...

Отзывы: