Installing and Changing Nutsetters and Locators

Depth Sensitive Units for Drill Point Screws

1. Select nutsetter size desired. 

2. Two locators are supplied, a 9/16" ID for 3/8" nutsetters and 1/2" ID for

5/16" nutsetters (1/2" ID supplied on unit). Match locator to desired size
nutsetter or bit holder. 

3. Drop nutsetter into nose of locator and wrap end of nutsetter until ball lock

snaps in groove in nutsetter shank.

4. To change the nutsetter or locator, pull forward on adjustment collar and

remove from clutch housing.

NOTE: Align ribs on inside of depth locator with grooves in clutch housing
before snapping into place. 

5. Depth locator is removable by unscrewing dust seal.

Changing Bit Tip

1. Pull forward on adjustment collar and remove it from clutch housing. It

may be quite stiff. (See Figure 3)

2. Use pliers to remove worn bit and install new bit tip.

Depth Adjustment: 

Drywall Units (2037-220, 2038-220)

1. Rotate adjustment collar (Figure 4). Clockwise rotation will provide deeper

seating of screws.

2. Test drive a fastener in scrap material to determine if fastener is correctly

seating.

3. Further adjustment may be necessary to increase or decrease the fastener

depth.

4. To increase depth, turn adjustment collar so that end of bit extends further

from end of locator.

5. To decrease depth, turn adjustment collar so that end of bit is closer to the

end of locator.

Figure 3

DEPTH
LOCATOR

ADJUSTMENT
COLLAR

BIT TIP
HOLDER

CLUTCH
HOUSING RETAINING

RING

BIT TIP

Figure 4

LOCATOR

ADJUSTMENT
COLLAR

154567/2037-220  5/17/02  1:34 PM  Page 3

Содержание 2037-220

Страница 1: ...Black Decker U S Inc 701 East Joppa Road Towson Maryland 21286 Printed in U S A FEB96 CD 1 Form No 154567 Copyright 1996 154567 2037 220 5 17 02 1 34 PM Page 2 ...

Страница 2: ...Instruction Manual 2037 220 2038 220 2054 220 2059 220 Screwdrivers 154567 2037 220 5 17 02 1 34 PM Page 3 ...

Страница 3: ... Insulation Double insulated tools are constructed throughout with two separate layers of electrical insulation or one double thickness of insulation between you and the tool s electrical system Tools built with this insulation system are not intended to be grounded As a result your tool is equipped with a two prong plug which permits you to use extension cords without concern for maintaining a gr...

Страница 4: ...bits cutters REMOVE ADJUSTING KEYS AND WRENCHES Form habit of checking to see that keys and adjusting wrenches are removed from tool before turning it on AVOID UNINTENTIONAL STARTING Don t carry tool with finger on switch Be sure switch is off when plugging in EXTENSION CORDS Make sure your extension cord is in good condition When using an extension cord be sure to use one heavy enough to carry th...

Страница 5: ...driving accessory Clutches are held apart by light spring pres sure permitting the driving clutch to rotate without turning the driven clutch and accessory When sufficient forward pressure is applied to the unit the clutches engage and rotate the spindle and accessories A reversing switch makes it possible to drive or loosen either right or left hand screws 2 Accessory Assembly The 1 4 hex drive b...

Страница 6: ...ust seal Changing Bit Tip 1 Pull forward on adjustment collar and remove it from clutch housing It may be quite stiff See Figure 3 2 Use pliers to remove worn bit and install new bit tip Depth Adjustment Drywall Units 2037 220 2038 220 1 Rotate adjustment collar Figure 4 Clockwise rotation will provide deeper seating of screws 2 Test drive a fastener in scrap material to determine if fastener is c...

Страница 7: ...ent collar until end of nutsetter is flush with end of locator 2 For large washer head and sealer screws adjust as above until nutsetter is recessed approximately 1 16 into the locator 3 Test drive a fastener in scrap material to determine if seating is correct 4 Readjust if necessary Depth sensitive units have very fine depth settings each click is 007 0ne revolution of the locator collar equals ...

Страница 8: ...ulties and will provide for immediate change in torque output giving the operator the option to drive a range of fastener sizes Changing Clutches 1 Remove clutch housing by unscrewing left hand thread 2 Clamp tool or clutch housing in a resilient clamp 3 Remove round clutch retaining rings with a very small screwdriver See Figure 8 4 Install new clutches and new retaining rings NOTE If the output ...

Страница 9: ...marked A B with B D clutch grease 69251 Coat clutch face inside nose of gear case Figure 9 4 On positive and versa clutch units the clutch assembly will not slip out of clutch housing It is necessary only to coat the clutch faces on these units 5 Reassemble clutch housing IMPORTANT To assure product safety and reliability particularly for double insulated tools repairs maintenance and adjustment e...

Страница 10: ... to be defective Conditions The service safety check and the warranty do not apply to repairs made or attempted by anyone other than an authorized B D service location misuse abuse neglect improper application of the tool missing parts or normal wear and tear after first year of ownership Please return the complete unit trans portation prepaid to any B D factory owned or B D authorized service cen...

Отзывы: