PLACING PRODUCT INTO THE CABINET 

 
 
In order to maintain a satisfactory product internal temperature and achieve a 2 hour holding time, 
cook products to Minimum 85 

o

C Maximum 90 

o

C, package quickly to minimise temperature loss 

& place directly into multi-deck merchandiser. 
 
Do not over-cook or overheat food items that are to be held hot, over-cooking will result in 
excessive moisture loss that will reduce holding times. 
 
Do not package and display products from another hot cabinet in the multi-deck merchandiser  
 
Check and record product temperatures every Hour. 
If a satisfactory holding time or correct product temperature is not achieved check the following:- 
 
 

 

Is the unit switched  “ON” ?  

 

Is the temperature controller set too Low/High ?  

 

Have you allowed enough Cabinet Pre-heat time before loading product ? 

 

Check product internal cook temperatures and bagging up procedures  

 

Rotate the food products. Check bagging times, Foods loaded in first should be sold first. 

 
 
 
 
 

UNIT SHUTDOWN 
 

Remove all food items left at the end of business. 
 
Turn cabinet main switch “OFF”. 
 
Remove all bagged products and any residue, allow the cabinet to cool. 
 
After the case has cooled to below 50 

o

C (Hand Hot), remove any residue from the well and clean 

the case thoroughly. 
 
 
 
 
 
 
 

 

 

Содержание Self Service Hot Food Merchandiser MODEL MHC4/8

Страница 1: ...THE COMBINATION OF FACTS DATA DESIGN ELEMENTS ENGINEERING DATA MANUFACTURING DATA ASSEMBLY DATA WHICH MAY BE CONTAINED IN THIS DOCUMENT ARE OF A PROPRIETARY NATURE TO BKI THESE MATERIALS ARE NOT TO BE USED OR COPIED WITHOUT PRIOR WRITTEN PERMISSION FROM BKI ALL RIGHTS ARE RESERVED ...

Страница 2: ...t as practical The unit is fitted with 2 control thermostats linked in series 1 variable and 1 hi limit Set 1 thermostat to 90 o C and the other to 110 o C Set Point is at 6 O clock This will provide a cabinet air temperature of between 75 80o C Ensure that the Cabinet is connected to a suitable power supply and that the power is ON the main ON OFF switch is to the rear of the Cabinet The Cabinet ...

Страница 3: ...urly and record on product temperature sheets PREHEATING Ensure shelves are clean before switching the cabinet main switch ON The cabinet is fitted with internal display lighting that will come on when the unit is plugged in and the main power supply is ON The unit is fitted with 2 control thermostats linked in series 1 variable and 1 hi limit Set 1 thermostat to 90 o C and the other to 110 o C Du...

Страница 4: ...ive moisture loss that will reduce holding times Do not package and display products from another hot cabinet in the multi deck merchandiser Check and record product temperatures every Hour If a satisfactory holding time or correct product temperature is not achieved check the following Is the unit switched ON Is the temperature controller set too Low High Have you allowed enough Cabinet Pre heat ...

Страница 5: ...ow to cool below 50 o C Hand Hot 3 Wipe shelves clean with a soft cloth and solution of Antibacterial detergent and warm water Note Do Not Remove Shelves 4 Wipe down Interior and exterior cabinet surfaces Except glass end panels with Antibacterial detergent solution 5 Dry all shelves and cabinet surfaces with a soft cloth or paper towel 6 Clean Glass end walls with Clearly Clean glass cleaner 7 Le...

Страница 6: ...e unit does not operate properly 4 Have only an authorised serviceman check and repair unit when needed TROUBLE SHOOTING PROBLEM CORRECTIVE ACTION Unit fails to operate 1 No Power 1 Assure that power is sound 2 Circuit breaker is off 2 Reset circuit breaker No Heat 1 Defective heating element 1 Replace heating element 2 Defective thermostat 2 Replace thermostat 3 Loose wire or bad connection 3 Rep...

Отзывы: