Rotisserie Ventless Hood
Maintenance
12
Maintenance
Electrocution could occur if this unit is hosed down with water. This unit is NOT
designed for hose wash-down cleaning! Refer to scheduled maintenance below
for proper hood cleaning.
Electrocution could occur if power is not removed from this unit before servicing.
Remove power at disconnect or circuit breaker
BEFORE
servicing hood.
Scheduled Maintenance
Use the following table to help manage scheduled maintenance activities.
FREQUENCY PERFORMED
BY
PART
ACTIVITY
Daily
User
Entire Hood
Wipe unit down with a soft rag and mild
cleaning agent.
User Condensation
trough
Check condensation trough. Empty if
necessary.
User
Grease Baffle
Clean grease baffle. If necessary, refer
to the procedure in this manual for
cleaning the baffle.
Weekly
User Charcoal/Odor
Filter
Inspect
charcoal/odor filter. In low to
medium volume applications, the filter
may need replacement prior to the
indicating light turning on. This
condition will be evident by a strong
odor coming from the face of the filter.
If necessary, refer to the procedure in
this manual for replacing the filter.
Monthly
User
Door and Filter
Interlock
Check door and filter interlock
operation. The unit should not operate
with the front door open or either the
grease baffle or charcoal/odor filter
removed. Clean area between grease
baffle and charcoal/odor filter.
Injury from rotating fan blades could occur if power is not removed from this unit
before cleaning the blower section. Remove power at disconnect or circuit breaker
BEFORE
cleaning the blower section.
3 Months
User
Blower Section
Clean the blower section.