
Gas Pressure Fryer
Introduction
3
Specific Precautions
Lids for LGF Pressure Fryers
manufactured prior to May 27, 1980 (or units with
serial numbers lower than 3613) could be manually opened while under pressure
resulting in serious injury or death. If you have one of these units, please contact
the BKI
Technical Services Department toll-free at 1-800-927-6887 for urgent
update information.
Risk of fire exists if the oil level drops below 5mm of the maximum oil level.
Use of oil/shortening older than the manufacturers recommendations for life of
the oil is prone to surge boiling and flash fires. Follow the oil manufacturers
guidelines for the life cycle of oil/shortening.
Do not open the drain valve or the fill valve while the fryer is under pressure.
Serious burns may result.
Follow instructions regarding effects of surge boiling of over-wet foods and
proper load size.
Equipotential ground plane
When a high current flows through a conductor, differences in potential appear
between the conductor and nearby metallic surfaces near the appliance. As a
result, sparks may be produced between the appliance and surrounding metal
surfaces. These sparks could cause serious injury, damage, or fire.
BKI provides an Equipotential ground terminal for the connection of a bonding
conductor after the installation of the appliance per lEC60417-1. This terminal is
located on the inside of the Power Entry Supply box near the Earth connection
and is marked with this symbol.
Full Disconnection
In accordance with Local and/or National wiring codes, the installer must provide
a means of full disconnection under over voltage Category III conditions. An IEC
approved cord and plug combination will meet this requirement.
Units not provided with a cord and plug do not meet this requirement. In
accordance with Local and/or National wiring codes, the installer must provide
the means of full disconnection.
The fryer is designed to hold a maximum of 35lbs (15.9KG) of oil/shortening.
Содержание LGF-F
Страница 1: ...Gas Pressure Fryer MODELS LGF F LGF FC Service Manual Serial Numbers 137733 and higher ...
Страница 11: ...Gas Pressure Fryer Introduction 9 Safety Labels ...
Страница 12: ...Gas Pressure Fryer Introduction 10 ...
Страница 33: ...Gas Pressure Fryer Replacement Parts 31 Figure 3 Lid Arm Assembly AN3211350S Sheet 1 of 4 ...
Страница 34: ...Gas Pressure Fryer Replacement Parts 32 Figure 3 Lid Arm Assembly AN3211350S Sheet 2 of 4 ...
Страница 35: ...Gas Pressure Fryer Replacement Parts 33 Figure 3 Lid Arm Assembly AN3211350S Sheet 3 of 4 ...
Страница 36: ...Gas Pressure Fryer Replacement Parts 34 Figure 3 Lid Arm Assembly AN3211350S Sheet 4 of 4 ...
Страница 38: ...Gas Pressure Fryer Replacement Parts 36 Figure 4 Dead Weight Pressure Gauge Assembly ...
Страница 40: ...Gas Pressure Fryer Replacement Parts 38 Figure 5 Drain Motor Piping Assembly ...
Страница 42: ...Gas Pressure Fryer Replacement Parts 40 Figure 6 Burner Tray Assembly Sheet 1 of 2 ...
Страница 43: ...Gas Pressure Fryer Replacement Parts 41 Figure 6 Burner Tray Assembly Sheet 2 of 2 ...
Страница 45: ...Gas Pressure Fryer Replacement Parts 43 Figure 7 Control Panel AB32200900 LGF F ...
Страница 47: ...Gas Pressure Fryer Replacement Parts 45 Figure 8 Control Panel AB32200700 LGF FC ...
Страница 49: ...Gas Pressure Fryer Replacement Parts 47 Figure 9 Door Assembly W Pocket SB3290 ...
Страница 51: ...Gas Pressure Fryer Replacement Parts 49 Figure 10 Oil Vat Assembly AN32112800 ...
Страница 58: ...Gas Pressure Fryer Wiring Diagrams 56 Wiring Diagrams ...
Страница 59: ...Gas Pressure Fryer Wiring Diagrams 57 ...
Страница 60: ...P O Box 80400 Simpsonville S C 29680 0400 USA http www bkideas com Made and printed in the U S A LI0294 0808 ...