![BK Precision 4014B Скачать руководство пользователя страница 65](http://html1.mh-extra.com/html/bk-precision/4014b/4014b_user-manual_2759835065.webp)
66
FREQuency <frequency>
The frequency command controls the frequency of
the output waveform.
Arguments
Type: Numeric.
Units: MHz, KHz, Hz (default)
Range: For SIN and SQU – 0.1 Hz to Max.
frequency (see specifications),
For TRI – 0.1 Hz to 1 MHz,
Rounding: The value is rounded to 5 digits or 100 mHz.
Command Type: Setting or Query
Setting
Syntax: FREQuency<ws><frequency>[units]
FREQuency<ws>MINimum|MAXimum
Examples: FREQ 5KHZ
FREQ 5E3
FREQ MAXIMUM
FREQ MIN
Query
Syntax: FREQuency?[<ws>MAXimum|MINimum]
Examples: FREQ?
FREQ? MAX
Response: NR3
Considerations: