Trigger
75
Setting Start Holdoff On
Figure 9.29
Start Hold-
off On
To set the start holdoff on:
1.
Press the Setup key or use the touchscreen controls to enter the
Trigger
menu.
2.
Use the touchscreen controls to select the
Start Holdoff On
option.
–
will appear.
3.
Use the touchscreen controls to select the desired start holdoff on.
9.7
Noise Reject
Noise Rejection
adds additional hysteresis to the trigger circuitry. By increasing the trigger hysteresis band, the possibility
of triggering on noise is decreased, however the trigger sensitivity is also decreased. A larger signal is required to trigger
the oscilloscope when
Noise Rejection
is enabled.
To enable
Noise Rejection
:
To set the start holdoff on:
1.
Press the Setup key or use the touchscreen controls to enter the
Trigger
menu.
2.
Use the touchscreen controls to select the
Noise Reject
option.
–
Tapping
Noise Reject
will toggle between the on and off mode.
Disabled
Enabled
Figure 9.30
Noise Reject
If the signal being probed is noisy, set up the oscilloscope to reduce the noise in the trigger path and on the displayed
waveform. First, stabilize the displayed waveform by removing the noise from the trigger path. Second, reduce the noise
on the displayed waveform.
•
Obtain a stable display.
•
Remove the noise from the trigger path setting Trigger coupling to LF Reject,
HF Reject
, or enabling
Noise Reject
.
•
Set the Acquisition mode to
Average
to reduce noise.
Содержание 2560B Series
Страница 1: ......
Страница 51: ...Digital Channels 51 Figure 8 9 Digital Bus...
Страница 127: ...Serial Trigger and Decode 127 Figure 10 63 Manchester Bus...
Страница 168: ...Reference Waveform 168 Figure 14 1 Recall REFB...
Страница 210: ...Save Recall 210 Figure 22 4 Save As...