GETM <address> <CR>
Memory 1 Voltage [???] Current [???] [CR]
Memory 2 Voltage [???] Current [???] [CR]
. . . . . . . . . . . . . . .
Memory 9
Voltage [???] Current [???] [CR] [OK] [CR]
Get All Preset Memory
Values from PS
GETM <address> location {1-9} <CR>
Voltage [???] Current [???] [CR]
[OK] [CR]
Get Memory from Specific
Preset of PS
GETP <address> <CR>
Program 00 Voltage [???] Current [???] Minute [??]
Second [??] [CR] Program 01 Voltage [???] Current [???] Minute [??]
Second [??] [CR]
. . . . . . . . . . . . . . . . . . . . .
Program 19 Voltage [???] Current
[???] Minute [??] Second [??] [CR] [OK] [CR]
Get all the Timed Program
Memory of PS
GETP <address> program {00-19} <CR
>
Voltage [???] Current [???] Minute
[??] Second [??] [CR] [OK] [CR]
To Get Anyone Timed
Program Memory from 20
Steps Program of PS
GPAL <address> [CR]
Reading voltage [####] V [ON] Reading current
[####] A [ON] Reading watt [####] W [ON] Timer minute [####] second
[##] timer [ON] colon [ON] m [ON] s [ON] Setting voltage [###] V-const
[ON] V-bar [ON] V [ON] Setting current [###] I-Const [ON] I-bar [ON] A
[ON] Program [#] Program [ON] P-bar [ON] SETTING [ON] Key lock [ON]
Key open [ON] FAULT [ON] Output on [ON] Output off [ON] Remote [ON]
[CR] [OK] [CR]
Get LCD Display
Information
VOLT <address> voltage {010-XXX} <CR>
[OK] [CR]
Set Voltage Level
XXX-Max. Output Rating
Voltage = XX
.
X V Current
= X
.
XX V