WARNING 

 

The following precautions must be observed to 
help prevent electric shock. 

 

1.

 

Use  only  a  polarized  3-wire  ac  outlet.  This  assures  that  the 
power supply chassis and case are connected to a good earth 
g r o u n d   a n d   reduces danger from electrical shock. 

 
2.

 

There is little danger of electric shock from the power supply 
output,  which  produces  a  maximum  of  14.0  volts  dc. 

However, there may be great danger of electrical shock if the 
power  supply  output  is  connected  to  an  external  high 
voltage.

  Some  equipment  being  powered  may  contain  high 

voltage  and  present  a  shock  hazard.  Observe  caution.  If  the 
power supply output is floated (referenced to a voltage rather 
than  earth  ground)  turn  off  the  power  supply  and  the 
equipment  under  test  when  making  connections.  Never  float 
the  power  supply  to  a  potential  greater  than  100  volts  peak 
with respect to earth ground. 

 
3.

 

Observe all TEST INSTRUMENT SAFETY precautions 
listed in the front of this manual. 

 

EQUIPMENT PROTECTION PRECAUTIONS 

 

CAUTION 

 

The following precautions will help avoid 

damage to the power supply. 

1.

 

Avoid  using  the  power  supply  in  ambient  temperatures 
above  +40°C  (104°F).  Always  allow  sufficient  air  space 
around the fan opening at the rear of the power supply and 
the  top  and  side  vent  openings  for  effective  air  flow  to 
prevent internal heat build-up. Typically, a two inch space 
at the sides, as well as a six inch space at the top and rear 
of  the  power  supply  is  adequate.  DO  NOT  block  the  fan 
opening at the rear of the power supply or the vent on top 
of  the power  supply.  DO NOT  place  objects  on top of  the 
power supply. 

 
2.

 

Although  the  power  supply  is  protected  against  overload 
and short circuits, avoiding these conditions in regular use 
results in maximum stability and reliability. 

 
3.

 

Make  certain  that  hook-up  is  as  intended  before  turning 
power  supply  on.  Incorrect  polarity  may  damage  the 
equipment being powered. 

 

POWER SUPPLY HOOK-UP and OPERATION 

 

1.

 

Turn off the power supply and equipment being powered.

 

Содержание 1686A

Страница 1: ...1 INSTRUCTION MANUAL MODEL 1686A 3 to 14 VOLT DC POWER SUPPLY...

Страница 2: ...hazard a If the equipment under test is the hot chassis type a serious shock hazard exists unless the equipment is unplugged just turning off the equipment does not remove the hazard or the precaution...

Страница 3: ...3 Instruction Manual for MODEL 1686A 3 to 14 VOLT DC POWER SUPPLY 22820 Savi Ranch Parkway Yorba Linda California 92887...

Страница 4: ...Power Supply Hook up and Operation 9 Considerations 10 Current Limiting 11 Connecting Two Supplies in Series 11 Connecting Two Supplies in Parallel 11 page MAINTENANCE 14 Fuse Replacement 14 Line Vol...

Страница 5: ...y radios such as CB transceivers VHF UHF commercial equipment marine car telephone and 2 meter transceivers The power supply utilizes thermostatically controlled fan cooling for improved heat dissipat...

Страница 6: ...voltage Short Circuit METERING Voltmeter Range Accuracy 0 to 20V 7 F S Ammeter Range Accuracy 0 to 20A 7 F S AC Input 115 230 VAC 10 50 60Hz POWER CONSUMPTION 400 W TEMPERATURE RANGE HUMIDITY Operatio...

Страница 7: ...eed 2 amperes 10 Line Cord 11 Fuse 12 Fan 1 POWER Switch Turns power supply on and off Power on indicated by pilot lamp above switch 2 Power ON light Lights when power is turned on 3 OVERLOAD Indicato...

Страница 8: ...8 CONTROLS AND INDICATORS Figure 1 Front Panel Controls and Indicators Model 1686A Figure 2 Rear Panel...

Страница 9: ...Observe all TEST INSTRUMENT SAFETY precautions listed in the front of this manual EQUIPMENT PROTECTION PRECAUTIONS CAUTION The following precautions will help avoid damage to the power supply 1 Avoid...

Страница 10: ...nugly to assure low resistance 2 Connect the red OUTPUT terminal of the power supply to the positive polarity input of the equipment being powered 3 Connect the black OUTPUT terminal of the power supp...

Страница 11: ...provide a variable 6 to 28 volts output The maximum output current will remain at 12 amps See Fig 4 for the connection scheme The voltage is controlled by both VOLTAGE controls and is equal to the sum...

Страница 12: ...12 OPERATING INSTRUCTIONS Figure 4 Connecting Two Power Supplies in Series for a 6 to 28 Volt Output...

Страница 13: ...13 OPERATING INSTRUCTIONS Figure 5 Connecting Two Power Supplies in Parallel for 3 to 14 Volt Output at Double Amperage...

Страница 14: ...e bottom of the chassis To convert to a different line voltage perform the following procedure 1 Make sure the power cord is unplugged 2 Turn the unit over bottom up and reset the LINE VOLTAGE SELECT...

Страница 15: ...14 50 0 10 volts on the multimeter 4 Set the power supply front panel VOLTAGE control for a reading of 14 00 0 10 volts on the multimeter 5 Adjust Trimmer VR4 so that the meter pointer on the V meter...

Страница 16: ...tive load for a reading of 15 amps on the unit s A meter scale 8 Adjustable Trimmer VR2 clockwise unit the output voltage read on the multimeter drops by 0 05 to 0 20 V INSTRUMENT REPAIR SERVICE Becau...

Страница 17: ...ccount must include payment in the form of a money order or credit card For the most current repair charges please visit www bkprecision com and click on service repair Return all merchandise to B K P...

Страница 18: ...nstrument via our website www bkprecision com Exclusions This warranty does not apply in the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs The warranty...

Страница 19: ...et is removed for servicing a serious shock hazard exists if the chassis is touched Not only does this present a dangerous shock hazard but damage to test instruments or the equipment under test may r...

Страница 20: ...20 B K Precision Corporation 22820 Savi Ranch Parkway Yorba Linda California 92887 www bkprecision com 2014 B K Precision Corporation 481 370 9 001 Printed in China V043014...

Отзывы: