Risk of electric shock. 

Pump models; All three phase pumps do 

not come with electric plug connectors. To reduce the risk of electric shock, be certain 

that it is connected only to a properly grounded, grounding-type receptacle. 

Lifting: 

Attach a rope or lifting chain (not included) to the handle (or lifting rings) on the top of 

the pump. 

 Do not lift the pump by the power cable or discharge hose/piping. 

Proper lifting equipment (rope/chain) must be used. 

POSITIONING THE PUMP 

BJM  Pumps

® 

SK-F  &  SKX-F  Series  pumps  are  designed  to  operate  fully 

submerged.  Data  sheets  can  be  obtained  online  at 

www.

flowsolutions

.com

  or  by 

calling 

Industrial Flow Solutions Operating

, LLC at 860-399-5937. 

Do not run pump dry.

Pump liquid should not exceed a maximum temperature of 200°F (93°C).

Never place the pump on loose or soft ground. The pump may sink, preventing

water from reaching the impeller. Place on a solid surface or suspend the pump

with a lifting rope/chain. The SK-F & SKX-F Series pumps are provided  with a

suction strainer to prevent large solids from clogging the impeller. Any spherical

solids which pass through the strainer should pass through the pump.

For maximum pumping capacity, use the proper size non-collapsible hose or rigid

piping. A check valve may be installed after the discharge to prevent back flow

when the pump is shut off.

Take  stand  off  of  pump  when  using  slide  rail.  Keep  stand  and  reattach  when

transporting or handling the pump.

Содержание FAHRENHEIT SK-F Series

Страница 1: ...e 208V 230V CAST IRON SINGLE PHASE SK1500C F 316 STAINLESS STEEL SINGLE PHASE SKX750CSS F SKX1500CSS F Read this manual carefully before installing operating or servicing these pump models Observe all...

Страница 2: ...HOOTING 13 PUMP WILL NOT RUN 13 PUMP RUNS BUT DOES NOT DELIVER RATED CAPACITY 14 SERVICING YOUR SUBMERSIBLE PUMP 14 MAINTAINING YOUR PUMP 14 CHANGING SEAL OIL 15 EXPLODED VIEW OF SK1500C F 16 EXPLODED...

Страница 3: ...tor or Industrial Flow Solutions Operating LLC Industrial Flow Solutions Operating LLC 104 John W Murphy Drive New Haven CT 06513 USA Phone 860 399 5937 Fax 860 399 7784 Information including pump dat...

Страница 4: ...eated Do not operate the pump with a worn or damaged electric power cable Death or serious injury could occur Never attempt to alter the length or repair any power cable with a splice The pump motor a...

Страница 5: ...fully read all tags decals and markings on the pump 6 Important Always verify that the pump nameplate amps voltage phase and HP ratings match your control panel and power supply Warranty does not cove...

Страница 6: ...ures the oil is covering the motor windings by and that will be above the upper bearing Do not overfill an air gap of 10 15 must be maintained for heat expansion PUMP INSTALLATION SK F SKX F Series pu...

Страница 7: ...impeller Place on a solid surface or suspend the pump with a lifting rope chain The SK F SKX F Series pumps are provided with a suction strainer to prevent large solids from clogging the impeller Any...

Страница 8: ...ways to check the correct pump rotation 1 By looking at the impeller the rotation of the impeller should be counter clockwise as shown in the picture below 2 By looking from the top of the pump Since...

Страница 9: ...ximum recommended starts should not exceed 10 times per hour All SK F SKX F Models are provided with a 50 15 m power cable NEVER splice the power cable due to safety and warranty considerations Always...

Страница 10: ...ontrol turn off the breaker and or turn the power source off generator CONTROL PANELS CONNECTION OPTIONS Use with approved motor control that matches motor input in full load amperes UTILLISER UN D MA...

Страница 11: ...12 Figure 1 SKX750F 115 control Figure 2 SKX750F 230 SK1500 230 and SKX1500 230 control...

Страница 12: ...Pumps control is supplied as a manual ON OFF control A wide angle float can be wired in series with the thermal sensors to allow the pumps to operate in an automatic mode See the wiring diagram provi...

Страница 13: ...tory or by a factory trained and certified repair technician to insure that the materials and assembly methods meet BJM Pumps standards MAINTAINING YOUR PUMP Pump should be disconnected from the elect...

Страница 14: ...ins water then the oil and possible the mechanical seal should be changed If an oil change is needed 9 Remove the screws that hold the oil chamber cover in place remove the oil 10 Replace the mechanic...

Страница 15: ...16 EXPLODED VIEW OF SK1500C F...

Страница 16: ...17 EXPLODED VIEW OF SKX750CSS F SKX1500CSS F...

Страница 17: ...8 31E Ground Wire w Ring Term 203145 32 Power Cord Line Clip Strain Relief 203161 33 Seal Minder Cable Line Clip 203163 34 Handle Chain Handle 202517 35 Rod Bolts 202668 38 Discharge Nipple 3 202534 3...

Страница 18: ...08 202408 31E Ground Wire w Ring Term 203145 203145 32 Power Cord Line Clip Strain Relief 203166 203166 33 Seal Minder Cable Line Clip 203163 203163 34 Handle Chain Handle 202517 202517 35 Rod Bolts 2...

Страница 19: ...20 SINGLE PHASE WIRING DIAGRAM 115V 230V MODELS SK1500CF SKX750CSS F SKX1500CSS F...

Страница 20: ...winding and allow for longer pump life The sensor cable consists of four leads two are connected to the Seal Minder and two are connected to the thermal sensor switches located in the stator windings...

Страница 21: ...excluded IT IS EXPRESSLY AGREED THAT THIS SHALL BE THE SOLE AND EXCLUSIVE REMEDY OF BJM PUMPS LLC S DISTRIBUTORS AND CUSTOMERS UNDER NO CIRCUMSTANCES SHALL BJM PUMPS LLC BE LIABLE FOR ANY COSTS LOSS E...

Страница 22: ...s No Condition of Equipment New Good Fair Poor Condition of Cable Jacket New Good Fair Poor Rotation Direction of Impeller Rotation viewed from bottom Use C W for clockwise CC W for counterclockwise R...

Страница 23: ...no Number of pumps operated by control panel NOTE At no time should hole be made in top of control panel unless proper sealing devices are utilized Short Circuit protection Type Number and size of sho...

Страница 24: ...ump on L1 L2 L3 FINAL CHECK Is pump secured properly Yes No Was pump checked for leaks Yes No Do check valves operate properly Yes No Flow Do pumps appear to operate at proper rate Yes No Noise level...

Страница 25: ...NOTES...

Страница 26: ...Operating LLC All rights reserved 2020 Industrial Flow Solutions Operating LLC All rights reserved Industrial Flow Solutions Operating LLC 104 John W Murphy Drive New Haven CT 06513 USA Phone 860 399...

Страница 27: ...F SK37C F SK55C F SK75C F SK110C F SK150C F 316 STAINLESS STEEL THREE PHASE SKX08CSS F SKX15CSS F SKX22CSS F SKX37CSS F SKX55CSS F SKX75CSS F SKX110CSS F SKX150CSS F Read this manual carefully before...

Страница 28: ...K55C F SKX55CSS F SK75C F SKX75CSS F 22 EXPLODED VIEW OF SK110C F SKX110CSS F SK150C F SKX150CSS F 23 SK F SERIES PARTS LIST 24 SKX F SERIES PARTS LIST 26 THREE PHASE WIRING DIAGRAMS 28 208V 28 MODELS...

Страница 29: ...questions regarding the inspection disassembly and assembly or testing please contact your BJM Pumps distributor or Industrial Flow Solutions Operating LLC Industrial Flow Solutions Operating LLC 104...

Страница 30: ...disconnect the pump power cable to ensure that the pump will remain inoperative 3 Allow the pump to cool if overheated Do not operate the pump with a worn or damaged electric power cable Death or ser...

Страница 31: ...e model numbers and serial numbers from the pumps and control panel on the front of this instruction manual for future reference Give it to the owner or affix it to the control panel when finished wit...

Страница 32: ...any damage For Storage Periods longer than 3 Years Disassemble the pump and replace all of the O rings the Mechanical Seal Seal Chamber Oil and the Lip Seal Repack the Bearings Remove the air check s...

Страница 33: ...0 1 300 ISO 32 NSF Food Grade Mineral Oil SKX22CSS F 13 5 400 ISO 32 NSF Food Grade Mineral Oil SKX37CSS F 13 5 400 ISO 32 NSF Food Grade Mineral Oil SKX55CSS F 84 5 2500 ISO 32 NSF Food Grade Mineral...

Страница 34: ...g Industrial Flow Solutions Operating LLC at 860 399 5937 Do not run pump dry Pump liquid should not exceed a maximum temperature of 200 F 93 C Never place the pump on loose or soft ground The pump ma...

Страница 35: ...ld be counter clockwise as shown in the picture below 2 By looking from the top of the pump Since the impeller cannot be seen the best way to check the rotation is to check the kick back motion of the...

Страница 36: ...SK F SKX F Models are provided with a 33 10 m power cord NEVER splice the power cable due to safety and warranty considerations Always keep the lead end dry Note 230V single phase and 208V 230V 460V...

Страница 37: ...tic mode unplug it from the power source turn off the breaker or turn the power source off generator Typical 3 phase manual control 1 TYPICAL AUTOMATIC WASTEWATERING INSTALLATION NOTE Maximum recommen...

Страница 38: ...r or turn the power source off generator INTENDED METHODS OF CONNECTION Use with approved motor control that matches motor input in full load amperes UTILLISER UN D MARREAR APPROUV CONVENANT AU COURAN...

Страница 39: ...instructions provided with the panel to wire the system For automatic three phase pumps see automatic three phase wiring diagram Typical 3 Phase Auto Control 1 Before installing a pump make sure both...

Страница 40: ...l Equipment UL 50 or the standard for Metallic Outlet Boxes UL 514A and the standard for Motor Operated Water Pumps UL 778 TROUBLE SHOOTING Disconnect the power source to the pump BEFORE attempting an...

Страница 41: ...at regular intervals More frequent inspections are required if the pump is used in a harsh environment Preventative maintenance should be performed to reduce the chance of premature failure Worn impel...

Страница 42: ...10 Replace the mechanical seal if necessary 11 Replace the oil 12 Assemble the pump STATOR REPLACEMENT OR ELECTRICAL REPAIR The BJM Pumps F Series designed pumps utilize unique construction methods an...

Страница 43: ...18 EXPLODED VIEW OF SK08C F SK15C F...

Страница 44: ...19 EXPLODED VIEW OF SKX08CSS F SKX15CSS F...

Страница 45: ...20 EXPLODED VIEW OF SK22C F SK37C F...

Страница 46: ...21 EXPLODED VIEW OF SKX22CSS F SKX37CSS F...

Страница 47: ...22 EXPLODED VIEW OF SK55C F SKX55CSS F SK75C F SKX75CSS F...

Страница 48: ...23 EXPLODED VIEW OF SK110C F SKX110CSS F SK150C F SKX150CSS F...

Страница 49: ...0962 200962 14 2 Lower Bearing Retainer 202279 202279 202279 202279 203075 203075 203076 203076 14 3 Lock Nut Lock Washer 200424 200424 15 Impeller Shim Kit Required 200480 200480 200480 200480 200478...

Страница 50: ...36 203279 203279 50 07 Screw for Oil Chamber Motor Housing 203228 203228 203228 203228 203271 203271 203280 203280 50 08 Screw for Oil Chamber Cover 203219 203219 203219 203219 203246 203246 203281 20...

Страница 51: ...76 14 3 Lock Nut Lock Washer 200424 200424 15 Impeller Shim Kit Required 200480 200480 200480 200480 200478 200478 200478 200478 17 Rotor w Shaft 3PH 204021 204022 204023 204024 204027 204028 204029 2...

Страница 52: ...6 203279 20327 50 07 Screw for Oil Chamber Motor Housing 203296 203296 203296 203296 203271 203271 203280 20328 50 08 Screw for Oil Chamber Cover 203219 203219 203219 203219 203246 203246 203281 20328...

Страница 53: ...28 THREE PHASE WIRING DIAGRAMS 208V MODELS SK08C F SKX08CSS F SK15C F SKX15CSS F SK22C F SKX22CSS F SK37C F SKX37CSS F SK55C F SKX55CSS F...

Страница 54: ...29 230V MODELS SK08C F SKX08CSS F SK15C F SKX15CSS F SK22C F SKX22CSS F SK37C F SKX37CSS F SK55C F SKX55CSS F SKX75C F SKX75CSS F SK110C F SKX110CSS F...

Страница 55: ...30 460V MODELS SK08C F SKX08CSS F SK15C F SKX15CSS F SK22C F SKX22CSS F SK37C F SKX37CSS F SK55C F SKX55CSS F SKX75C F SKX75CSS F SK110C F SKX110CSS F SK150C F SKX150CSS F...

Страница 56: ...31 575V MODELS SK08C F SKX08CSS F SK15C F SKX15CSS F SK22C F SKX22CSS F SK37C F SKX37CSS F SK55C F SKX55CSS F SKX75C F SKX75CSS F SK110C F SKX110CSS F SK150C F SKX150CSS F...

Страница 57: ...and allow for longer pump life The sensor cable consists of four leads two are connected to the Seal Minder and two are connected to the thermal sensor switches located in the stator windings These fo...

Страница 58: ...33...

Страница 59: ...excluded IT IS EXPRESSLY AGREED THAT THIS SHALL BE THE SOLE AND EXCLUSIVE REMEDY OF BJM PUMPS LLC S DISTRIBUTORS AND CUSTOMERS UNDER NO CIRCUMSTANCES SHALL BJM PUMPS LLC BE LIABLE FOR ANY COSTS LOSS E...

Страница 60: ...by hand Yes No Condition of Equipment New Good Fair Poor Condition of Cable Jacket New Good Fair Poor Rotation Direction of Impeller Rotation viewed from bottom Use C W for clockwise CC W for counter...

Страница 61: ...no Number of pumps operated by control panel NOTE At no time should hole be made in top of control panel unless proper sealing devices are utilized Short Circuit protection Type Number and size of sho...

Страница 62: ...ump on L1 L2 L3 FINAL CHECK Is pump secured properly Yes No Was pump checked for leaks Yes No Do check valves operate properly Yes No Flow Do pumps appear to operate at proper rate Yes No Noise level...

Страница 63: ...NOTES...

Страница 64: ...Operating LLC All rights reserved 2020 Industrial Flow Solutions Operating LLC All rights reserved Industrial Flow Solutions Operating LLC 104 John W Murphy Drive New Haven CT 06513 USA Phone 860 399...

Отзывы: