background image

 

 

                                                                                                     

                                                                                                               

 

                                              

 

BJ-885 BJOY Ring

                                                                                                                      

Page 7

 

In order to correctly assemble the equipment it is important to take 
into account the following indications:  

o

 

Protect the switch input box from liquids. 

o

 

Avoid water entering via the USB cable. 

o

 

Use the USB extension lead if the cable does not reach directly.  

o

 

It is recommended to use assemly inclinations of under 45º. 

 
3_How to use the BJOY Ring mouse 

In  order  to  start  using  the  BJOY  Ring  mouse  the  USB  connection 
cable must be plugged into the computer’s USB port.  

IMPORTANT: 

In  order  to  access  the  computer  the  wheelchair 

must be first disconnected. 

Although  the  device  adapts  to  the  assembly  position,  when  it  is 

connected to the computer’s USB port it must be calibrated in order 
to  obtain  the  best  response  from  the  joystick’s  movements.  The 
following steps must be followed in order to perform the calibration:  

1)

 

Install the provided BJOY configuration software.  

2)

 

Do the calibration (See section 4.2.5 of the “BJOY configuration 

programme” in this manual). 

Once the calibration is done the device can be used like the joystick 
of  the  wheelchair.  To  move  the  cursor  on  the  computer  screen  you 

just need to move the joystick in the desired direction.  

To avoid the cursor moving on the computer screen when you want 
to drive the wheelchair, you have to deactivate the mouse by closing 

the  session  on  the  computer,  disconnecting  the  USB  cable  or 
configuring  the  “Deactivate”  option  using  the  configuration  software 

(See  section  4.2.4  of  the  “BJOY  configuration  programme”  in  this 
manual). 

If  due  to  a  slight  change  in  the  position  of  the  joystick  the  mouse 

moves  slightly  without  moving  the  lever,  the  device  can  be 
deactivated and then reconnected in order to recognise a new resting 

position.  If  this  occurs  frequently  or  the  position  of  the  wheelchair 
joystick  is  not  stable,  the  “minimum  inclination”  value  can  be 

modified  using  the  configuration  software  (See  section  4.2.5  of  the 
“BJOY configuration programme” in this manual). 

The  two  external  switches  which  are  connected  to  the  entries 

indicated as A and B of the box for switch entries must be used to do 

Содержание BJ-885

Страница 1: ...c Mare de D u del Coll 70 08023 Barcelona Spain t 34 93 285 04 37 fax 34 93 553 56 34 info bjliveat com www bjliveat com BJ 885 BJOY Ring User Guide...

Страница 2: ...installed in an inclined position up to 45 Compatible with all wheelchair models the model must be chosen which is adapted to your wheelchair It has two customisable switches to perform the functions...

Страница 3: ...panner The joystick allows the cursor moving in all directions The two configurable switches allows the click functions of the mouse to be performed left click right click double click and drag drop T...

Страница 4: ...to obtain detailed information on the configuration By default the entry A performs the left click function and the entry B the right click function 2 2 Assembly of the equipment In order to assemble...

Страница 5: ...g is set up in positions with 90 turns in relation to the chair s forward position If it is set up in different positions the mouse will not respond properly 3 3 Tighten the mounting screw using the s...

Страница 6: ...ive hood It is important to always put on the protective hood 5 5 Reassemble the joystick handle onto the wheelchair 6 Install the configuration software and do the calibration See section 4 2 5 of th...

Страница 7: ...he BJOY configuration programme in this manual Once the calibration is done the device can be used like the joystick of the wheelchair To move the cursor on the computer screen you just need to move t...

Страница 8: ...ion software See section 4 2 2 of the BJOY configuration programme in this manual For the correct use of this device you are recommended to Do not use it in moving vehicles Do a calibration if there i...

Страница 9: ...CD the installation should begin automatically If it does not browse to the CD or removable drive and click on BJOYSetup exe file If using the web page go to section Downloads and click on BJOY Softwa...

Страница 10: ...must have a BJOY device connected to your computer In case you do not have any BJOY device connected the following screen will appear IMPORTANT if you want that the settings are applied to the BJOY d...

Страница 11: ...the movement of the cursor while you are moving the wheelchair Select from the Shutdown switch drop down list the entry which you want to deactivate the device with If you have selected entry A or B...

Страница 12: ...order to calibrate the BJOY activate the Start button and follow the steps indicated in the screen In the event that small movements in the wheelchair s joystick cause undesired cursor movements you...

Страница 13: ...in the device follow these steps 1 Activate the File menu 2 Select Load settings 3 Find the file corresponding to the stored configuration files are saved with the extension BJOY Click on the Open but...

Страница 14: ...quids entering into the switch box as this could seriously damage the equipment o The equipment is not designed to be used outdoors o Do not manipulate the device in the event of a fault 6_ Technical...

Страница 15: ...e environmental or human harm which could be caused by uncontrolled waste disposal separate these products from other types of waste and correctly recycle them This will promote the sustainable reuse...

Страница 16: ......

Отзывы: