<Function 367> GS ( k pL pH cn n (fn=67)
Code:
ASCII
GS
(
k
pL
pH
cn
fn
n
Hex
1D
28
6B
03
00
33
43
n
Decimal
29
40
107
3
0
51
67
n
Range:
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=51
fn=67
1
≤ n ≤ 8
Default:
n=2
Description:
This command sets the
2-dimensional GS1 DataBar
size.
Remarks:
■
This command affects the execution of <Function 381>.
■
The setting of this command remains effective until ESC @, printer reset or power cycling is executed.
■
Since the
2-dimensional GS1 DataBar
module is square, n = module width = module height.
Differences:
None