SRP-330II/332II
Rev. 1.00
BIXOLON
- 7 -
2-2 Details of Control Commands
HT
Function:
Horizontal tab
Code:
ASCII
HT
Hex
09
Decimal
9
Range:
None
Default:
None
Description:
This command moves the print position to the next horizontal tab position. If the next horizontal tab position is not
specified, this command will be void.
Remarks:
■
The horizontal tab position is set by <ESC> D.
■
With the underline mode turned on, the underline printing is not applied to the tab space created by this command.
Differences:
None