4.3.11 Reconnect 

 

In real application, the data center may be shut down or have issue, and that will cause 

TW810 disconnects from data center, while in order to keep TW810 always online, it will 

try to reconnect the data center, and that will cause unnecessary data flow. So you can 

configure those 2 functions to save the data flow, when Reconnect Time Interval enabled, 

TW810 will try to reconnect data center, and if Connect Retry Times exceed the value you 

set,  while  TW810  is  still  unable  to  reconnect  to  data  center,  TW810  will  do  exception 

handling.   

4.3.12 ECHO Heartbeat Interval 

 

We suggest you keep it as default settings, as it is not supported by TW810 now. 

4.3.13 TTL Heartbeat 

 

It’s a reserved feature, we suggest you keep it as default settings, as it is not supported by 
TW810 now. 

4.5 MODBUS Setting 

Modbus is a reserved feature, and not supported by TW810 now. 

 

5. Firmware Upgrade 

5.1  Please open the Bivocom Config Tool, as below,   

1)  Configure Serial Port parameters 

 

Baud Rate: 115200 

 

Data Bit: 8 

 

Stop Bit: 1 

 

Parity Bit: None 

2) 

Click ‘Download Tool’ 

3) 

Click ‘Load’, choose the firmware you want to upgrade 

4) 

The click ‘Download’ 

Содержание TW810-B20

Страница 1: ...Addr Unit 704 No A3 Building Tel 86 592 6211770 3rd Software Park Xiamen China 361000 Fax 86 592 6211727 www bivocom com sales bivocom com 1 Industrial NB IoT Cellular Modem TW810 Series User Guide...

Страница 2: ...ions and information in this document are subject to change without any notice and BIVOCOM reserves the right to improve and change this user guide at any time Users should take full responsibility fo...

Страница 3: ...rial Cellular NB IoT Modem TW810 Series Please thoroughly read this user guide before you configure and install the device This manual is compatible with below models Model Description TW810 B5 Indust...

Страница 4: ...ion 8 3 3 1 SIM UIM Card 9 3 2 2 Cellular Antenna 9 3 2 3 Terminal Block Power Cable and Console Cable 9 3 3 Power Supply 10 3 4 LED Indicators 11 4 Serial Port Configuration 11 4 1 Operations 12 4 1...

Страница 5: ...Number 18 4 3 3 Dialing Settings 19 4 3 4 Heartbeat Interval 19 4 3 5 Auto Back to Main Server 19 4 3 6 Custom Register String 20 4 3 7 Custom Heartbeat String 20 4 3 8 Transfer Meaning 20 4 3 9 TCP M...

Страница 6: ...the needs of industrial standards and industrial users It adopts high powered industrial 32 bits CPU multi layer software detection and hardware protection mechanism to ensure reliability and stabili...

Страница 7: ...ales bivocom com 7 3 Getting Started WARNING Please make sure the device is powered off before you install and configure it 3 1 Package Checklist Check the package before you configure and install the...

Страница 8: ...Building Tel 86 592 6211770 3rd Software Park Xiamen China 361000 Fax 86 592 6211727 www bivocom com sales bivocom com 8 3 2 Dimensions There are 3 holes for installation at each side of TW810 Unit m...

Страница 9: ...tall SIM UIM card when NB IoT Modem is powered on 3 2 2 Cellular Antenna Fasten the cellular antenna Screw the SMA male cellular antenna to TW810 SMA female interface make sure it is screwed tightly t...

Страница 10: ...nal block we suggest you use 28 16AWG power cable and console cable Definition of power cable and console cable in this package are as below Power Cable Output 12VDC 0 5A Color of cable Power Output P...

Страница 11: ...dicators Online ACT Power System as follows 4 Serial Port Configuration Connect TW810 to your laptop or computer through RS232 then open Bivocom configuration tool TW810 exe Click on the left side cho...

Страница 12: ...entering into configuration status 4 1 Operations 4 1 1 Save Click to save the parameters you ve configured 4 1 2 Load Load the parameters of TW810 to config tool and display 4 1 3 Clear Output Clear...

Страница 13: ...211727 www bivocom com sales bivocom com 13 4 1 7 Restart Restart TW810 4 1 8 Save Config Save configuration of TW810 in file format which you can use it recover the config 4 1 9 Configure via Saved C...

Страница 14: ...rent 4 2 2 SIM Card No The Number of SIM inserted in this modem 4 2 3 Work Mode Keep the default settings DTU as work mode MODEM and IMODEM are not supported on TW810 DTU Transfer the data to server t...

Страница 15: ...and Stopbit You can choose below from drop down menu 8N1 8 Databit No Parity 1 Stopbit 8E1 8 Databit Even Parity 1 Stopbit 8O1 8 Databit Odd Parity 1 Stopbit 7O1 7 Databit Odd Parity 1 Stopbit 7E1 8 D...

Страница 16: ...e to TW810 only available on TD210 Cellular modem http www bivocom com index php m content c index a show catid 12 id 22 2 Data Trigger On Password You can set up trigger data in the blank once the tr...

Страница 17: ...com sales bivocom com 17 4 3 Networking Setting 4 3 1 Network Work Mode There is one network work mode supported on TW810 right now NUDP Pure UDP CUDP Custom UDP and HUDP DCUDP are unavailable now TW8...

Страница 18: ...0 will connect to main center once it couldn t connect to backup center it will continue to connect to main center till it s connected 2 5 means TW810 supports multi centers and all the other centers...

Страница 19: ...Center please ask your mobile carriers for those info if you have any questions 4 3 4 Heartbeat Interval Heartbeat time we suggest you keep it as default settings 4 3 5 Auto Back to Main Server Y Aut...

Страница 20: ...of register string is up to 70 bytes 4 3 7 Custom Heartbeat String You can configure it when network word mode is configure as CUDP but you can also choose not to configure it which means register st...

Страница 21: ...onnect data center and if Connect Retry Times exceed the value you set while TW810 is still unable to reconnect to data center TW810 will do exception handling 4 3 12 ECHO Heartbeat Interval We sugges...

Страница 22: ...d Software Park Xiamen China 361000 Fax 86 592 6211727 www bivocom com sales bivocom com 22 5 2 Power on the TW810 then device will start to upgrade the firmware as below 5 3 After firmware upgrading...

Страница 23: ...1770 3rd Software Park Xiamen China 361000 Fax 86 592 6211727 www bivocom com sales bivocom com 23 5 4 Then use the Config Tool to enter into the configuration status set up the device to factory sett...

Страница 24: ...r MIXD Mixed Trigger Call Trigger Phone No AT CTRLNO XX XX Preset call trigger phone No SMS Trigger Password AT SMSDPSWD XX XX Preset SMS trigger password Data Trigger On Password AT DONPSWD XX XX Tri...

Страница 25: ...N Password AT PASSWORD XX XX APN Password APN Call Center AT CENT XX XX APN Call Center Heartbeat Interval AT POLLTIME XX XX Heartbeat Interval Auto Back to Main Server AT RETMAIN XX XX 1 Yes 0 No Cus...

Страница 26: ...DCMODE1 XX XX 0 Disable 1 Collect Once 2nd Analog Work Mode AT ADCMODE2 XX XX 0 Disable 1 Collect Once 1st Digital Work Mode AT DIOWORKMODE1 XX XX 0 Disable 1 Input 2 Output 2nd Digital Work Mode AT D...

Страница 27: ...k Xiamen China 361000 Fax 86 592 6211727 www bivocom com sales bivocom com 27 2 Is the RS232 RS485 connected to your computer or laptop and serial port of computer or laptop is working 3 Check whether...

Отзывы: