Addr.: Unit 704, No. A3 Building, Tel: +86-592-6211770
3
rd
Software Park, Xiamen, China 361000 Fax: +86-592-6211727
www.bivocom.com
32
Reconnect Time Interval
AT+RDLWT=XX
XX: Reconnect Time Interval
TTL Heartbeat
AT+EXFUN=XX
XX: 0, Disable
1, Enable, 1 time per 60
seconds
ECHO Heartbeat Interval
AT+ECHOINT=XX
XX: 0, Disable
Other
value
means
seconds you set
1
st
SMS Send Phone No. AT+PHONE1=XX
XX: Use comma for multi
phone number
2
nd
SMS Send Phone No.
AT+PHONE2=XX
XX: Use comma for multi
phone number
3
rd
SMS Send Phone No.
AT+PHONE3=XX
XX: Use comma for multi
phone number
4
th
SMS Send Phone No.
AT+PHONE4=XX
XX: Use comma for multi
phone number
SMS Send Type
AT+HEXSMS=XX
XX: 0, Normal SMS
1, HEX SMS
SMS Send Backup
AT+OPENSMSBCKP=XX
XX: 0, NO Backup
1, YES, to Backup
Display SMS Receiving
AT+SMSDIS=XX
XX: 0, No, SMS is not
displayed at serial port
1, Yes, SMS display at
serial port
MODBUS Work Mode
AT+MBMODE=XX
XX: 0, Disable
1, Network MODBUS
2, Serial Port MODBUS
MODBUS Device Address AT+MBADDRESS=XX
XX: Address ranging from
1-247
1
st
Analog Work Mode
AT+ADCMODE1=XX
XX: 0, Disable
1, Collect Once
2
nd
Analog Work Mode
AT+ADCMODE2=XX
XX: 0, Disable
1, Collect Once
1
st
Digital Work Mode
AT+DIOWORKMODE1=XX
XX: 0, Disable
1, Input
2, Output
2
nd
Digital Work Mode
AT+DIOWORKMODE2=XX
XX: 0, Disable
1, Input
2, Output
3
rd
Digital Work Mode
AT+DIOWORKMODE3=XX
XX: 0, Disable
1, Input
2, Output