background image

About Us 

Biuged Laboratory Instruments 

Guangzhou

Co. Ltd. 

has been focusing on developing and 

innovating  high-quality  and  high-precision  instruments  for  50  years.  We  are  the  biggest  and  most 

professional manufacturer of testing instruments for paint, coating, ink and printing field in China. All our 

products are in according with ISO, ASTM, EN standards etc and get CE Certification.   

Originally founded in 1963, Biuged have grown to an internationally recognized company with many 

worldwide customers base which includes the world leading paint and coatings manufactures. 

At the same time, Biuged has a young, motivate and vibrant team. Our R&D department continually 

investigates new product design ideas, in conjunction with the major standards committees. In order to 

supply  up  to  date  instrumentation  for  the  Quality  Control  of  coatings,  we  always  apply  the  advanced 

contemporary techniques and experience to our new products. Our manufacturing department ensures 

that all our products are built to the highest quality, every instrument undergoing rigorous calibration and 

testing before it leaves our premises.   

Moreover, Biuged has own independent Calibrate laboratory and more than 40 agents and offices 

all over the world. We are also the major member of Chinese Standardization Technology Committee of 

Paint and Pigment. 

Produce the highest cost-effective products and offer the most professional service are Biuged 

mission. Satisfying our customers’ needs are our ultimate wishes.

 

   

Factory 

Address

No.8,Fuhe Industrial Area, Zhongfu Road, Zhongxin Town, Zengcheng district, Guangzhou 

City. China 

Tel

020-32955999

10line

 

Fax

020-32955818 

E-mail

[email protected]

 

 

Guangzhou office

 

Address

RM.101,NO.3, Sicheng Rd., Gaotan Software Park, Tianhe District, Guangzhou.China 

510663 

Tel

020-82169666 

Fax

020-82340996 

E-mail

[email protected] 

  

Shanghai office

 

Address: 

No.6066, Huqingping Road., Zhujiajiao Town, Qingpu District, Shanghai City, China.   

Tel

021-59240298 

Fax

021-59249719 

E-mai

l

[email protected] 

 

Содержание BGD 160/1

Страница 1: ... INSTRUCTION MANUAL BIUGED LABORATORY INSTRUMENTS GUANGZHOU CO LTD Add RM 101 NO 3 Sicheng Rd GaotangSoftware Park Tianhe District Guangzhou China 510663 Tel 0086 20 32955999 Fax 0086 20 32955818 E mail service biuged com Website www biuged com ...

Страница 2: ...nd experience to our new products Our manufacturing department ensures that all our products are built to the highest quality every instrument undergoing rigorous calibration and testing before it leaves our premises Moreover Biuged has own independent Calibrate laboratory and more than 40 agents and offices all over the world We are also the major member of Chinese Standardization Technology Comm...

Страница 3: ...and max range Print interval can be set Stepping motor drived by high segmentation and Microcomputer based technology make the spindle rotate smoothly measure accurately Main board subdivision drive plate all adopt the SMT technology Circuit design uses the most advanced microcomputer processor the structure layout is compact and reasonable Operational accessories PT100 temperature probe RS232 com...

Страница 4: ...BGD 160 series portable digital viscosity measuring instrument schematic diagram BGD 160 series portable digital viscosity measuring instrument Spindle installation diagram ...

Страница 5: ...ttery charger 1 5 Spindle B1 B2 B3 B4 1 6 Lithium battery 1 Operational accessories 1 PT100 temperature probe 2 Miniprinter 3 Portable bracket 4 Special waterbath 5 Remote control 6 Lifting support Model BGD 160 1 BGD 160 2 BGD 160 3 Range mPa s 25 150 000 50 300 000 200 1200 000 Speed R Min 60 100 150 200 60 100 150 200 60 100 150 200 Spindle Four types B1 B2 B3 B4 Viscosity Accuracy 2 0 Full ran...

Страница 6: ...l Unscrew the screw on main roller Insert spindle into main roller Screw the screw Install spindle sleeve Watch sleeve bottom and spindle keep coaxial or not Then fix the sleeve with the M3 screw 3 4 If equip PT100 temperature probe insert it into temperature port If equip miniprinter connect to the Rs232 port Key Functions Restart program and stop viscosity Print or timing function Choose speed S...

Страница 7: ...r runs About 3 hours later the green indicator light runs and charging complete After that viscometer can be used without charging for 8 hours 4 3 Click S button to change spindle number B1 B2 B3 B4 B1 The number must connect with the real spindle 4 4 Click R button to change speed For example 60 100 150 200 rpm 4 5 Click M button to start to measure the viscosity and torque with the spindle and t...

Страница 8: ...inaccuracy 6 4 Viscosity and the spindle is a group Don t mix with other viscosity and spindle 6 5 Don t remove or adjusting the viscosity and the other parts 6 6 When instrument needs to be moved fix the screw and put it into the package 6 7 There is a lot of Non Newtonian fluid in suspension liquid emulsion high polymer and other high viscosity liquid Their viscosity changed with speed time or s...

Страница 9: ... B4 spindle is used to measure high viscosity The time for measure with low speed is longer than the high After use according to the figure must clean the spindle and cylinder in time Otherwise will affect the measurement accuracy 7 0 Others If you want to know more detail information or get a catalog please visit www biuged com or contact with Biuged headquarters or our agents in different region...

Отзывы: