numbers only. If the login and password are set by SMS, they shall be
specified in each SMS with commands.
Adjustment of I/O elements
The tracking device “BI-530R TREK” is able to collect, process and
send to the server the data received from various sensors. Each sensor is
an I/O element and has a group consisting of 6 parameters for setting.
For example, to set the value of power supply voltage level to the server,
use group of parameters of ID 0410/0411/0412/0413/0414/0415. These
options have the following structure:
0410/0411/0412/0413/0414/0415
First 3 numbers (green) refer to parameter group number to
configure the I/O element.
Last
number
(grey)
is
a
parameter
number.
6 parameters (from 0 to 5) are available for a single I/O element.
Possible values of these parameters are presented in Table 5.
Table 5 – List of parameters of I/O elements
Parameter
number
Description
Possible values
0
Enable/disable I/O
element
0 – disabled; 1 – enabled
1
Priority of I/O element
at transmission
0 – low; 1 – high
2
Upper limit
(depending on the type of I/O
element)
3
Lower limit
(depending on the type of I/O
element)
4
Setting of the type of
the generated event
0 – entering the range;
1 – leaving the range;
2 – returning/leaving to/of the
range;
3 – monitoring;
4 – moni entering the
range;
5 – moni leaving the
range;
6 – moni return to/leaving
the range;
7 – generation of the event to
change the input value to a
predetermined value;
8 – generation of the event to
change the input value to a
predetermined value + monitoring
5
Averaging constant
From 0 and higher