BITMAIN apw5-12-2600 series Скачать руководство пользователя страница 8

   

8   

4.   The   PSU   must   be   installed   in   such   a   way   that   it   receives   good,   unobstructed   airflow.   
Under   no   circumstances   should   the   PSU   be   installed   in   an   enclosed   place.   
5.   When   installing   the   PSU,   please   double   check   that   the   output   polarities   are   the   
correct   way   round,   and   that   the   screws   are   fastened   securely   in   place.   
6.   Do   not   attempt   maintenance   on   any   wiring   while   the   PSU   is   powered   up   from   the   
mains.   
7.   Running   the   PSU   at   <80%   load   or   below   can   greatly   prolong   the   life   of   the   PSU.   
Usually,   for   every   10ºC   above   the   rated   amount,   the   life   of   the   PSU   is   cut   in   half.   

   

   

   

Содержание apw5-12-2600 series

Страница 1: ... 1 BITMAIN APW5 12 2600 PSU Series User Guide ...

Страница 2: ... 2 Content 1 Overview 3 2 Features 3 3 Specifications 4 4 Order Information Wire Type 6 5 Trouble Shooting FAQ 7 6 Precautions for Use 7 ...

Страница 3: ... 1 This PSU cannot be used in countries where the mains power voltage is lower than 100V because the PSU will not start below this voltage 2 Features l 110V 120V 20 voltage input range l High efficiency up to 94 6 l Short circuit overload and overheat protection l Extreme power density l An active power factor corrector function PF 0 99 full load l Fan speed changes with temperature l User can cha...

Страница 4: ...Range 90 265V AC Current Range 10 5 16 5A Starting Voltage 100 240V AC Frequency Range 47 63Hz Power Factor 0 95 full load Leakage Current 1 5mA 220V 50Hz Protection Low voltage Input 90 100V AC Output Short Circuit Yes Output Overcurrent 220V input 216 255A Output Overcurrent 110V input 108 135A Overheat Protection Yes Environment Conditions Operating Temperature 20 60 Operating Humidity 20 90 RH...

Страница 5: ...aph 220V input Efficiency vs Load 220V input 216 216 216 216 200 160 170 180 190 200 210 220 20 0 20 50 55 60 Input220V current A Temp Current A 84 0 86 0 88 0 90 0 92 0 94 0 96 0 10 60 110 160 210 Efficiency efficiency EFF load current A ...

Страница 6: ... 6 4 Order Information Wire Type 4 1 Order Information 4 2 Wire Types 7 pairs of 6 pin PCI E connectors 380mm length for each PCI E ...

Страница 7: ...whether there is a dust buildup inside the PSU due to prolonged use Do NOT remove the PSU s cover unless trained to do so 4 Check that the power and ambient temperatures follow the Load Temperature graph 4 Output is normal but the fan is not working Fan is broken 1 Check that the fan is clear of blockages or buildup 2 Fan is broken and needs to be replaced 5 The PSU suddenly has no output and can ...

Страница 8: ...g the PSU please double check that the output polarities are the correct way round and that the screws are fastened securely in place 6 Do not attempt maintenance on any wiring while the PSU is powered up from the mains 7 Running the PSU at 80 load or below can greatly prolong the life of the PSU Usually for every 10ºC above the rated amount the life of the PSU is cut in half ...