System Configuration and status 

5.1

 

System Upgrading 

Through ‘System->Upgrade’, you will be able to upgrade your 

serv

er.

‘Keep setting’ is chosen by default, you should choose it if you hope to preserve the current settings. 
You should cancel this option if you hope to restore to initial settings. 
Click ‘Browse’ button to choose upgrade file. After choosing upgrade file, then click ’Flash image...’ 
button, it will remind if upgrading software, start to download software after choosing upgrading 
software.  During  the  upgrade  process,  you  need  to 

wait  patiently,  and  must  keep  power 

on, otherwise, 

the server

 should be shipped to factory to restore.

 You will see bellow screenshot

after upgrading successfully. 

Choose ‘Reboot’ button, 

server

 will restart and run the new system. Choose ‘Go Back’, 

server

will continue running the old system, will run new system when power on next time. 

5.2

 

Password Modification 

Through ‘System->Administration’, you can modify AntMiner login password, and choose ‘Save’ 
and ‘Save and Apply’ after modifying it. 

Содержание AntMiner S4

Страница 1: ...BITMAIN S4 Server Manual ...

Страница 2: ... Overview 3 2 Connect to Server 3 3 Server Configuration 4 3 1 Pool Setting 4 3 2 Frequency Modification 5 4 Server Status 5 5 System Configuration and status 6 5 1 System Upgrading 6 5 2 Password Modification 6 5 3 Software Version Checking 7 5 4 Restore Initial Setting 7 ...

Страница 3: ...lso status LEDS reset button and beep on the screen Casing size 3U Rack 432mm 442mm 133mm 2 Connect to Server Step 1 The default DHCP network protocol distributes IP addresses automatically After you have your server hooked up you will see the IP address on the LCD display Step 2 Connect your server to the PC with network cable Step 3 Enter server s IP address into your web browser then login in t...

Страница 4: ...t up with three mining pools the priority decreases from first pool pool 1 to third pool pool 3 The pool with low priority will start to work only when the high priority pool breaks down 3 1 2 With Beeper ringing checked beeper will ring when the server stops mining otherwise it won t ring even if the server stops mining 3 1 3 With Stop running when temperature is over 80 checked the server will s...

Страница 5: ...ed Settings E g Voltage 0720 means operating voltage of chip is 0 72V Voltage needs to be modified when adjusting the frequency 4 Server Status Click the status marked below you can check the operating status of your server ASIC ASIC number in the chain Frequency ASIC setting frequency Temp Temperature centigrade ASIC status o stands for OK x stands for error ...

Страница 6: ...ck Flash image button it will remind if upgrading software start to download software after choosing upgrading software During the upgrade process you need to wait patiently and must keep power on otherwise the server should be shipped to factory to restore You will see bellow screenshot after upgrading successfully Choose Reboot button server will restart and run the new system Choose Go Back ser...

Страница 7: ...ion you used After upgrading the software to check if you are using the latest version of software via File System Version 5 4 Restore Initial Setting Press the Reset button on the left bottom of LCD screen and hold on for 3 seconds red led flashing every one second 1S Release Reset button the server will restore the initial setting and restart automatically ...

Страница 8: ...Page 8 8 S4 Server Manual Last updated 9 29 2014 Page 7 of 8 ...

Отзывы: