2

 

Connect to Miner 

Step  1.  Manually  set  up  your  PC’s  IP  address  in  the  network  segment  same  as  the  miner’s  IP 
address. Default IP address of S2 is 192.168.1.99 by default, set up PC’s address to 192.168.1.x. 
Step 2. Connect miner and your PC via network cable. 
Step3. Enter miner’s IP address into your web browser, then login miner management interface, 
both of username and password is ‘root’ by default.

 

 
Through ‘Network’, you will be able to modify AntMiner IP address, and choose ‘Save and Apply’ 
after modifying it. 

 

Through Diagnostics page, you can check your network connection. 

 

Содержание AntMiner S2

Страница 1: ...BITMAIN AntMiner S2 Manual ...

Страница 2: ...ge 2 of 9 Page2 9 Contents 1 Overview 3 2 Connect to Miner 4 3 Pool Setting 5 4 Miner Status 6 5 System Configuration and status 7 5 1 System Upgrading 7 5 2 Password Modification 8 5 3 Software Version Checking 8 5 4 Restore Initial Setting 9 ...

Страница 3: ...e Fab out 1000W PSU when you set up AntMiner S2 only need to connect to AC 220V 50Hz or 110V 60Hz LCD screen here show IP Address Hashrate the highest temperature There are also Status LEDS Reset button and Beeper on the screen All 5 fans for cooling 4 bigger fans one small fan Casing size 442mm 432mm 177mm which is suitable to install in the server cabinet ...

Страница 4: ... 1 99 by default set up PC s address to 192 168 1 x Step 2 Connect miner and your PC via network cable Step3 Enter miner s IP address into your web browser then login miner management interface both of username and password is root by default Through Network you will be able to modify AntMiner IP address and choose Save and Apply after modifying it Through Diagnostics page you can check your netwo...

Страница 5: ...ee mining pools the priority decreases from first pool pool 1 to third pool pool 3 The low priority pool will start to work only when the high priority pool encounter fault 2 3 2 When Beeper ringing is chosen beeper is to alert once the miner stops mining otherwise beeper won t alert even if the Miner stops mining 2 3 3 When Stop running when temperature is over 80 is chosen Miner won t mine if th...

Страница 6: ...1 Miner Status web page Through Miner Status you will be able to check your miner running status ASIC ASIC number in the chain Frequency ASIC setting frequency Temp Temperature centigrade ASIC status o stands for OK x stands for error 4 2 LCD Screenshot IP address 192 168 1 98 ...

Страница 7: ... 80 Degree Celsius and all fans are not spinning up red LED keep lighting and beeper rings 5 System Configuration and Status 5 1 System Upgrading Through System Upgrade you will be able to upgrade your miner Keep setting is chosen by default you should choose it if you hope to preserve the current settings You should cancel this option if you hope to restore to initial settings Click Browse button...

Страница 8: ...hen power on next time 5 2 Password Modification Through System Administration you will be able to modify AntMiner login password and choose Save and Save and Apply after modifying it 5 3 Software Version Checking Through System Overview you will be able to check the software version you used After upgrading the software to check if you are using the latest version of software via File System Vers...

Страница 9: ... of 9 Page9 9 5 4 Restore Initial Setting Press the Reset button on the left bottom of LCD screen and hold on for 3 seconds red led flashing every one second 1S Release Reset button Miner will restore the initial setting and restart automatically ...

Отзывы: