Additional  sensors  such  as  Electrooculography  (EOG)  and  Electrogastrography  (EGG)  are 
also  available  for  connection  to  an  analog  port.  For  a  full  list  of  available  and  compatible 
sensors, please visit the 

BITalino store

. 

 
The correct electrode cable (2-/3-lead) can be found in Table 4 and the setup in Figure 13 with 
markers on the back of the sensor for correct alignment marked in green,  sensor and cable 
alignment marked in red and battery connection marked in blue. 

 

Table 4: Sensors and electrode cable combinations. 

Sensor 

2-lead 

3-lead 

Additional info 

ECG 

 

x

 

 

EDA 

 

 

EMG 

2-lead + 1-lead 

(REF) 

EEG 

 

 

 

 

Figure 13: Setup for the BITalino Plugged kit and Core with Cables and Sensors (red) and battery connection 

(blue). The markers on the back of the sensor for correct alignment is marked in green. 

 

 

Содержание (r)evolution

Страница 1: ...BITalino r evolution User Manual...

Страница 2: ...f the possibility of such damages ATTENTION Please read this User Manual before using your BITalino r evolution device The information contained in this document has been carefully checked and were ma...

Страница 3: ...ITalino r evolution Plugged and Core 15 2 2 3 Assembled BITalino Core 17 2 3 ECG Signal with BITalino r evolution boards 19 3 Using the BITalino r evolution boards with OpenSignals 20 3 1 Configuring...

Страница 4: ...cables red and battery connection blue 15 Figure 12 BITalino r evolution Plugged and Core connection ports for sensors and actuators Sensors for connection to an electrode cable marked in red 15 Figu...

Страница 5: ...able 3 Sensors and electrode cable combinations 14 Table 4 Sensors and electrode cable combinations 16 Table 5 Assembled Sensors for the BITalino Assembled Core 17 Table 6 Electromagnetic emissions Th...

Страница 6: ...luetooth low energy BLE BT dual mode for data transfer A BITalino r evolution Core The BITalino hub Core is available as a separate part for do it yourself experiments assembled with a 3D casing or as...

Страница 7: ...he Light Emitting Diode LED and the Buzzer BUZ The sensors are namely Electrodermal Activity EDA Electrocardiography ECG Electromyography EMG Electroencephalography EEG Light LUX Pushbutton BTN and th...

Страница 8: ...tion Plugged BT see Figure 4 Figure 4 BITalino Plugged kit BT Components of the Core and sensors b BITalino r evolution Plugged BLE BT dual mode see Figure 5 Figure 5 BITalino Plugged kit BLE BT Compo...

Страница 9: ...kit with all needed accessories for an experimental setup such as the Plugged kit a BITalino r evolution Board kit BT see Figure 6 Figure 6 BITalino Board kit BT Components of the Board with sensors a...

Страница 10: ...uators LED BUZ Battery 700 mA 3 7V LiPo rechargeable Operating Voltage 3 3V Input Voltage Range 3 0 5 5V Sampling Frequency 1 10 100 or 1000Hz Analog Sensor Ports 4 in 10 bit 2 in 6 bit 1 auxiliary in...

Страница 11: ...ual 11 of 30 The sleeve color meaning for the 2 and 3 lead electrode are described in Table 2 Table 2 Sleeve color meanings for UC E6 connection Sleeve Color Red Black White Electrode Cable 2 lead Ele...

Страница 12: ...teristics The BITalino Core comes in a size of 65mm x 56mm x 2 mm see Figure 8 Figure 8 Physical characteristics of the BITalino Core BT The BITalino Board comes in a size of 65mm x 108m x 2mm see Fig...

Страница 13: ...BITalino r evolution User Manual 13 of 30 2 Application Notes 2 1 Quick Start Guide...

Страница 14: ...BITalino r evolution User Manual 14 of 30...

Страница 15: ...G EDA ECG and EMG need to be attached to an electrode cable using the sensor port marked in red Figure 10 BITalino r evolution Board with pre connected sensors and actuators Sensor ports for connectio...

Страница 16: ...alogue ports A1 A6 see Figure 12 All parts can be connected to the board using a sensor cable see Figure 12 lower right The sensor BTN can be connected to the port I1 I2 The actuators such as LED and...

Страница 17: ...Table 4 and the setup in Figure 13 with markers on the back of the sensor for correct alignment marked in green sensor and cable alignment marked in red and battery connection marked in blue Table 4 S...

Страница 18: ...The analogue ports marked in green see Figure 14 are for the connection to the sensors namely EMG EDA ECG EEG ACC Z ACC XYZ EOG EGG BTN LUX Respiration RIP Photoplethysmography PPG High Definition Te...

Страница 19: ...BITalino r evolution User Manual 19 of 30 BTN LUX RIP PPG TMP FSR...

Страница 20: ...ignal of the Einthoven Lead I Please see the ECG Sensor Datasheet for more information regarding the ECG signal Figure 15 ECG acquisition Assembled Core left Plugged Core middle and Board right with e...

Страница 21: ...tion Windows macOS Linux Open the OpenSignals r evolution device manager to access and configure your BITalino device see Figure 17 Figure 17 Access the OpenSignals r evolution device manager Select t...

Страница 22: ...onnected to Activate the channel for acquisition by clicking on the circle next to the channel type must be blue see Figure 20 If not done before follow the instruction available in section 2 Applicat...

Страница 23: ...ugmented Reality in Virtual Reality and Augmented Reality EuroVR 2020 Lecture Notes in Computer Science Springer Cham vol 12499 no 17 pp 83 95 2020 F bio Mendon a Sheikh Shanawaz Mostafa Fernando Morg...

Страница 24: ...ing your BITalino system to prevent any damages or problems with the user test persons and or BITalino devices Violations of these instructions can lead to inferior signal quality and or damages to th...

Страница 25: ...any of its accessories Any repairing of the device must only be done by properly trained and authorized PLUX personnel During the charging process place the device and the charging equipment so that t...

Страница 26: ...Directive 2014 53 EU Article 3 1 b Electromagnetic Compatibility Radio Equipment Directive 2014 53 EU Article 3 2 Efficient use of Spectrum Standards Rohs Directive 2011 65 EU Intended Data of manufa...

Страница 27: ...transportation of the system and avoid dropping it since the device is not shock proof and should not be placed under stress or sudden acceleration 5 4 Cleaning Please follow these cleaning instructio...

Страница 28: ...with proven defects at no cost to the client During the repair period PLUX promises to provide a temporary replacement under the same specification Repairs will be carried out at PLUX s premises afte...

Страница 29: ...earch applications they are not medical devices nor are they intended for medical diagnosis cure mitigation treatment or prevention of disease we expressly disclaim any liability whatsoever for any di...

Страница 30: ...ail plux plux info web http www plux info Headquarters Zona Industrial das Corredouras Lt 14 1 2630 369 Arruda dos Vinhos Portugal tel 351 263 978 572 fax 351 263 978 902 Lisbon Office Av 5 de Outubro...

Отзывы: