13
Start Up
PROCEDURE
Do not attempt to operate the air compressor without first checking the oil level
in the pump.
Drain and replace oil as required. Serious damage may result from running without oil.
1. Check to see that all nuts and bolts are snug.
2. Check that compressor is on a stable level surface.
3. Check that air filter is clean.
4. Do not place any materials on or against the compressor.
5. Open the drain valve at the bottom of the tank.
6. Turn the pressure switch lever to “AUTO”.
7. Ensure air is escaping from the drain valve. Allow the unit to operate for a minimum
of twenty minutes in this no load condition.
8. After running the compressor for twenty minutes, close the drain valve and allow
the unit to reach maximum operating pressure. Ensure that the compressor shuts
down at the preset maximum pressure. Notice that the head pressure is released
through the unloading valve of the pressure switch.
9. Check the air compressor and piping systems for leakages.
10. Recheck the oil level in the crankcase. Add oil as required.
11. Your compressor is ready for use.
WARNING
• Before doing any maintenance or adjustments to your air compressor, the
following safety precautions should be taken.
A. Disconnect electrical power.
B. Drain air tank to release air pressure.
START UP