background image

P

repared by Monique Lania 

 

 

 

Call Servicing Guide QuickWash 

1950F.doc

 

 

 

 

 

Troubleshooting 

Bissell Quickwash BS-1950F 

 
 

CONTENTS PAGE 

 
Consumer states the 

handle screw will not attach

……………………..…….…Page 2 

 
Consumer states

 unit will not spray

……………..………………….…………..…Page 3 

 
How to change 

(remove and fit) brush/bare floor attachment

………………..Page 9 

 
Consumer states 

no suction

………………………………………………………...Page 10 

 
The unit is 

not sucking while using bare floor tool

………….………………….Page 11 

 
Consumer states 

no power

……..……………………………………………………Page 12 

 
Consumer states the unit is 

leaking at the spray bar

…………………………….Page 13 

 
Consumer states the

 unit is very noisy

…………………………………………….Page 14 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание Quickwash BS-1950F

Страница 1: ...l not attach Page 2 Consumer states unit will not spray Page 3 How to change remove and fit brush bare floor attachment Page 9 Consumer states no suction Page 10 The unit is not sucking while using ba...

Страница 2: ...place while at the same time turning the screw on the back with a screwdriver NOTE It does require a bit of force Will the handle screw attach now Insert screw into screw hole using a Phillips Head sc...

Страница 3: ...full in order for the unit to spray Has the solution tank been refilled No Empty dirty water collection tank and replace back into machine Yes proceed to solution 2 Using the Formula Measuring Cap ad...

Страница 4: ...ch the machine off There may be a slight air lock in the machine You will need to remove the air lock Now when you press the trigger as you move backwards over the floor using the machine the solution...

Страница 5: ...code J01111 were made without the raised screw hole If this is the case the screw should not be protruding past the back surface of the unit Is the handle screwed in correctly Yes proceed to solution...

Страница 6: ...oceed to solution 5 No remove handle is it damaged Yes advise customer to call Bissell Free Call 1800 number again and press Option 4 for spare parts and order replacement handle No Ensure handle is a...

Страница 7: ...ter front of the solution tank A keyed insert on the cap and tank should guide the tube for proper placement NOTE Units made prior to date code J01032 did not have this keyed insert The consumer will...

Страница 8: ...tank holding the solution tank upright with the black cap insert at the bottom Is the water level in the solution tank below the hole No tip out solution making sure it is only filled to full on the...

Страница 9: ...y water collection There are two grey pieces of plastic where the brush sits sticking up through 2 holes Push these pieces of plastic towards each other with your thumbs and down so that the brush dro...

Страница 10: ...d to solution 2 Remove any debris from the black foam filter in the dirty water collection tank No remove dirty water tank and re install making sure to follow installation instructions carefully Turn...

Страница 11: ...or tool look damaged No proceed to solution 2 Yes advise customer to call Bissell Free Call 1800 number again and press Option 4 for spare parts and proceed to order replacement floor tool Attach bare...

Страница 12: ...states no power Solution 1 Try the unit in another outlet that you know is functioning Has a functioning appliance in it already Is the cord plugged into a functioning power outlet No plug unit into...

Страница 13: ...ll it How Slide handle assembly down into the lower body of the unit until it will go no further Place Phillips head screw into rear of handle assembly making sure the screw for the handle is aligned...

Страница 14: ...deeply embedded dirt out of your carpet However it has passed all Australian Electrical Appliance Safety standards including noise level tests Also the designers have tried to keep the unit as compac...