Wire
1. Please use rubber cable for power cord.
Minimum speci
fi
ca
ti
on recommended for extension wires
Rated
current
7.5
15
22.5
30
45
45
m
m
m
m
m
m
0-5A
1.5
mm
2
1.5mm
2
1.5mm
2
2.5 mm
2
4mm
2
4mm
2
5.1-8A
1.5
mm
2
1.5mm
2
2.5 mm
2
4mm
2
4mm
2
4mm
2
8.1-12A
2.5
mm
2
2.5 mm
2
4mm
2
/
/
/
2. When using air compressors, if you need to use an extension wire, please use our
recommended speci
�
ications (if the extension wire length is too long or the speci
�
ication
is too small, it will cause pressure drop and cause start-up dif
�
iculty) :
Air compressor maintenance
The daily maintenance
Before daily use
:
1. Check whether the connec
ti
on of power cord and pipeline is reliable.
2. Make sure all nuts and bolts are fastened.
3. Check for abnormal sounds or vibra
ti
ons.
After daily use
:
First drain the compressed gas in the tank, then open the drain valve to drain the water in the
tank.
Weekly maintenance:
1. Check all bolts, nuts and pipe connec
ti
ons for looseness
aft
er the
fi
rst 50 hours of
opera
ti
on of the new machine.
2. Pull the TAB of the relief valve to make sure it is func
ti
oning properly.
3. Check whether the func
ti
on of the pressure switch is normal every week, and set whether
the pressure is 0.8mpa.