CHIMNEY INSTALLATION NOTES 

 

1.

 

If possible, install an interior chimney as it will provide better performance.  In areas with 
continuous temperatures below -18° C (0° F), the use of an exterior chimney increases the 
likelihood  of  operating  problems  such  as  low  draught,  high  rate  of  creosoting,  and  poor  
start-up  characteristics.    Exterior  chimneys  are  also  prone  to  down-drafting  and  flow 
reversal.    Installations,  which  are  located  on  lower  floors  in  the  house,  such  as  in  a 
basement, in combination with outside chimney, are especially prone to flow reversal. 

NOTE: In areas where winter temperatures are normally below freezing, the air cooled chimney 
may  produce  condensation.    This  condensation  may  corrode  the  top  of  the  fireplace  and  is  not 
covered  under  warranty.    For  optimum  performance  of  your  fireplace,  Security  Chimneys 
International recommends the use of an ASHT+/ or S2100+/ chimneys. 

2.

 

The  Security  fireplace  model  BIS  Ultima

  CF  fireplace  is  listed  only  with  Security 

Chimneys International Ltd 6" diameter chimney systems. 

3.

 

A chimney venting a fireplace shall not vent any other appliance. 

4.

 

The minimum chimney height is 12 ft. (3.7 m). 

5.

 

All  chimney  installations  must  include  at  least  one  support.    Reducing  the  amount  of 
chimney  weight  on  the  fireplace  will  help  avoid  the  noise  created  when  the  fireplace 
expands.    This  can  be  achieved  by  having  the  chimney  supported  by  the  supports.    The 
maximum  chimney  length  that  can  be  supported  by  the  fireplace  is  9  ft.  (2.75  m)  for  
S-2100+/,  12  ft.  (3.7  m)  for  ASHT+  /      and  26  ft.  (8  m)  for  AC 
chimney.  In altitude, add 18" (450 mm) to the chimney for every 2000 feet (600 m) above 
sea level. 

6.

 

The chimney must extend at least 3 ft. (915 mm) above its point of contact with the roof 
and at least 2 ft. (610 mm) higher than any wall, roof or building within 10 ft. (3m) of it 
(Figure 24).  

 

7.

 

If  the  chimney  extends  higher  than  5  ft. 
(1500 mm) above its point of contact with 
the  roof,  it  must  be  secured  using  a  roof 
brace. 

8.

 

A rain cap must be installed on top of the 
chimney. Failure to install a rain cap may 
cause corrosion problems. 

9.

 

Cut  and  frame  square  holes  in  all  floors, 
ceilings, and roof that the chimney will go 
through  to  provide  a  2"  (50  mm) 
clearance  between  the  chimney  and  any 
combustible materials.  Do not fill this 2" 
space  with  insulation  or  any  other 
combustible material. 

10.

 

Portions  of  the  chimney  which  may 
extend through accessible spaces must be 
enclosed 

to 

avoid 

contact 

with 

combustible  materials  or  damage  the 
chimney. 

 

Figure 24 

Содержание Ultima CF

Страница 1: ...ll the fireplace only as described in these instructions SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE THIS UNIT REQUIRES THE INSTALLATION OF A FINISHING KIT SEE SECTION 3 1 1 FOR DETAILS This fireplace is also certified for use in mobile or manufactured homes 2125 Monterey St Laval Quebec Canada H7L 3T6 Printed in Canada Rev 0 August 2010 PIBISULTIMACF Hot Do not touch The glass and surfaces of th...

Страница 2: ...are 3 3 6 Ashes 3 3 7 Refractory Installation 3 3 8 Door Installation 3 3 9 Door Adjustment 3 3 10 Glass Care Replacement 3 3 11 Glass Care Cleaning 3 3 12 Gasket Replacement 3 4 FIREPLACE INSTALLATION 12 3 4 1 Locating the BIS Ultimatm CF 3 4 2 Finishing kit installation 3 4 3 Hearth Extension Requirements 3 4 4 Framing Facing and Mantel 3 5 HOT AIR DUCTING INSTALLATION 17 3 5 1 Gravity Kit 3 5 2...

Страница 3: ...res surrounding the fireplace installation Such openings to require a household tool for access The vapour barrier of the mobile home shall be as close as possible of the location where the chimney assembly penetrates the ceiling and roof structure with no interference to the required clearance to combustible material When the mobile or manufactured home has a flat roof the Attic Radiation Shield ...

Страница 4: ...2 2 CERTIFICATION LABEL ...

Страница 5: ...hese instructions will void the certification and the warranty of the fireplace and may result in an unsafe installation 3 1 1 Parts Required Fireplace model BIS Ultima CF Includes the following kits 1 Outside air kit 2 Blower kit with thermo disc Your choice of finishing kit 1 Louver kit 2 Clean face obstruction plate kit Must be used in conjunction with a gravity vent kit see section 3 5 1 SEE S...

Страница 6: ...s on the packaging prior to use 3 2 2 First Fires Before using the fireplace make sure to remove the plastic wrapping on the door Remove all remaining glue with mild soap The first 5 or 6 fires should be small fires of short duration about 30 to 60 minutes This will help cure the refractory bricks The first fires may produce slight smoking due to drying of the paint and steel and any dust accumula...

Страница 7: ...lowing for a longer burn time The combustion air control should be in the closed position primary air and air boost when the fireplace is not in use This will minimize air leakage up the chimney The combustion air control should be opened before opening the door to minimize the possibility of back draft coming into the room Figure 1 3 2 5 Accelerated Combustion The maximum heat output for the BIS ...

Страница 8: ... door This method of burning should be used only after operating the BIS Ultima CF fireplace with the air control opened to produce a hot fire for about an hour or at medium pace for at least 3 hours Slow combustion can be used at night in order to reduce the heat output and to prolong the burn The loading time will be between 6 8 hours 3 2 8 Refuelling For Best Performance The BIS fireplace will ...

Страница 9: ...m C Wet wood Wet or tarred wood will smoulder and smoke instead of burn properly D Dirty or blocked chimney Check to make sure the chimney is clear and clean E Chimney not long enough The minimum chimney height is 12 ft not including the fireplace height The chimney must extend at least 3 feet 915 mm above its point of contact with the roof and at least 2 feet 610 mm higher than any roof or wall w...

Страница 10: ...ccumulation is large a creosote fire in the chimney can damage the chimney and overheat the surrounding wood framing Creosote formation in a chimney can be minimized by making sure there is always visible flame burning avoid smouldering fires and by proper refuelling techniques 3 3 2 Chimney Maintenance Regular chimney inspection and maintenance combined with proper operation will prevent chimney ...

Страница 11: ...stion air controls 2 Alert your family of the possible danger 3 If you require assistance alert your fire department 4 If possible use a dry chemical fire extinguisher baking soda or sand to control the fire Do not use water as it may cause a dangerous steam explosion 5 Check outside to ensure that sparks and hot embers coming out of the chimney are not igniting the roof 6 Do not use the fireplace...

Страница 12: ...To install the new refractories follow the above steps in reverse Figure 2 3 3 8 Door Installation Your fireplaces door has been factory installed and adjusted To remove the door simply unscrew the top hinge from the door than lift the door without touching the trim over the door to disengage the male part of the bottom hinge from the female part The door adjustment has been set at the factory If ...

Страница 13: ...ler can recommend a suitable cleaner which is available in your area Regular household glass cleaners will not clean creosote Do not use abrasives such as steel pads steel wool or oven cleaner as they will scratch the glass DO NOT USE CHEMICAL GLASS CLEANERS ON PAINTED SURFACES AS IT MAY CAUSE THE PAINT TO PEEL CAUTION Do not allow window cleaner to get in contact with door gasket or paint on the ...

Страница 14: ...ghts are given in the appendix Next measure the area occupied by the fireplace which is normally 36 X 24 Note the floor construction and consult your local building code to determine if additional support is needed C The BIS UltimaTM CF fireplace may be installed directly on the floor or on a raised base for proper guidelines refer to Hearth Extension Requirements and a minimum of 6 8 measured fro...

Страница 15: ...uction plates to cover the top and bottom openings allowing to install the finishing material closer to the door WARNING The bottom obstruction plate is designed to leave an opening area for the convection air to circulate and cool your fireplace NEVER BLOCK THIS AIR SPACE TO AVOID OVERHEATING THE FIREPLACE AND POTENTIALLY CAUSE A FIRE IN YOUR HOME See section 3 5 1 to install the gravity vent kit...

Страница 16: ...rom using screws that could interfere with your finishing material Place the bottom bend on the lower trim and push on it to insert the top bend Push on the part so the ends lie well on the fireplace face 5 Install the bottom part the same way Make sure to push the part to the bottom to leave the required air space 6 Use sheet metal screws on all 4 corners to secure the installation Figure 3 4 2 2...

Страница 17: ... in place of the safety metal strip shown on Figure 5b The safety strip should extend the full width of the fireplace When more than one safety strip is used they must overlap by a minimum of 1 Hearth extension of an elevated fireplace must respect the same minimal dimensions as a fireplace installed directly on the floor figure5a 3 4 3 Framing Facing and Mantel The construction of the framing fac...

Страница 18: ...eplace a space the thickness of the facing material so that the facing can be installed flush with the fireplace facing Frame headers between the vertical studs only as follows Place 2 x 3 or 2 x 4 headers only along the upper part of the front side and back faces Do not put wood or any combustible material within the area above the fireplace except on the front facing Place headers only as requir...

Страница 19: ...ce on the floor see figure beside Bend the nailing flanges down so each flange is flush with the floor then using nails or screws secure the fireplace to the floor 2 places each side The heads of the screws must be large enough to cover the holes on the nailing flanges Unbend to floor and nail screw Nailing flange ...

Страница 20: ...ee figure 12 and 12a NOTE non combustible materials like brick stone or ceramic tiles may be overlay on the fireplace front see figure 12b 2 Facing with the clean face kit The 2x3 framing must offset to the back by a distance equivalent to the thickness of the gypsum Combustible materials must be installed to be aligned with the fireplace front and can not overlay on the fireplace front black stee...

Страница 21: ...all 2 x 3 Min 51mm x 76mm Spacer Fireplace Frame section Top View 1 Fireplace 2 Wood frame 2 x 3 Min 3 Drywall 4 Tiles or Brick Noncombustible Facing Drywall 2 x 3 Min Spacer Rock Board or Other 1 Fireplace 2 Wood frame 2 x 3 Min 3 Drywall 4 Tiles or Brick Only non combustible material should be superposed or projecting over this surface Noncombustible Facing Drywall 2 x 3 Spacer Do not obstruct g...

Страница 22: ... allow hot air flow that would normally come out of the top louver To do so follow the steps below a Install the clean face kit making sure that the insulation strip is installed inside b The fireplace façade can be covered with non combustible material fig 18 WARNING both pipes of the double hot air outlet must be installed Any other installation may cause fire and void warranty Figure 15 The saf...

Страница 23: ...ore heat out of the higher outlet figure 16 Figure 16 Figure 18 Maintain at least 6 1 2 160mm clearance from the outlet grill framing to a combustible ceiling side wall or mantel WARNING The outlet grills should not be installed facing upwardthrough a floor Danger of burns can result if grills in floor are stepped on 10 3 1m Max 10 3 1m Max 13 x 13 330mm x 330mm Rain Cap Roof Support Attic Radiati...

Страница 24: ...t the wall or floor penetration The hole size must be 13 X 13 330 mm x 330 mm 6 Do not connect the hot air ducts to a central heating system Malfunction of the heating system s fan will cause the fireplace to overheat A furnace duct is only single wall and not double wall as is required for the BIS Ultima CF fireplace hot air exhaust 7 Use only Security Chimneys International grills and components...

Страница 25: ... Fix the back draft damper to the fan outlet F Attach a flexible pipe to the fan flexible pipe adapter square to round and stretch it up to the location where the heat is required G At that point the flexible pipe can be attached to any air distribution grill It is possible to connect a flexible pipe to a central heating system Make sure the pipe will be connected to the warm air supply duct not t...

Страница 26: ... the fireplace C The fresh air must come from outside the house The air intake must not draw air from the attic from the basement or garage D The air intake should be installed where it is not likely to be blocked by snow or exposed to extreme wind and away from automobile exhaust fumes gas meters and other vents E The duct and register may be installed above or below floor level The following com...

Страница 27: ... is 12 ft 3 7 m 5 All chimney installations must include at least one support Reducing the amount of chimney weight on the fireplace will help avoid the noise created when the fireplace expands This can be achieved by having the chimney supported by the supports The maximum chimney length that can be supported by the fireplace is 9 ft 2 75 m for S 2100 HT6000 12 ft 3 7 m for ASHT HT6103 and 26 ft ...

Страница 28: ... in place turn of a turn clockwise With the AC chimney you must use a starter section before installing the first chimney length figure 28 Continue installing chimney lengths making sure to lock each length in place 4 Every time the chimney passes through a ceiling or a wall install the appropriate firestop When you reach the desired height install the roof support Refer to instructions included w...

Страница 29: ...HIMNEY Figure 28 Figure 27 Figure 27a NOTE outside air kits are mandatory for AC chimney and recommended for the fireplace Mandatory chimney outside air intake Outside air kit Rain Cap Collar Flashing Attic Radiation Shield Firestop AC Starter Section ...

Страница 30: ... 14 1 8 359 mm 15 380 mm 2 12 12 9 16 319 mm 14 3 8 365 mm 15 3 8 390 mm 4 12 13 330 mm 14 7 8 378 mm 16 1 8 410 mm 6 12 13 7 8 352 mm 15 400 mm 16 7 8 430 mm 8 12 14 7 8 378 mm 17 432 mm 18 1 4 465 mm 10 12 16 1 8 410 mm 18 3 8 467 mm 19 5 8 500 mm 12 12 17 1 2 445 mm 20 508 mm 21 3 8 545 mm CROSS SLOPE HOLE SIZE AC CHIMNEY ...

Страница 31: ...e centre of the hole Cut a hole for the chimney in the ceiling floor Frame this hole as described previously refer to page 22 5 From below install a firestop See figure 26 6 A support ST or SO must be used on the first 15 section 5 m 7 Continue with the regular installation AC Chimney 1 Install the first elbow Turn it in the required direction To lock it in place turn 1 8 of a turn Fasten the stra...

Страница 32: ...ETWEEN ELBOWS 8 12 18 24 36 48 8 48 12 48 18 48 24 48 36 48 48 48 Secure Temp S2100 Nova Temp HT6000 15º DEVIATION 3 5 16 84mm 4 5 16 110mm 5 7 8 149mm 7 7 16 189mm 10 1 2 267mm 13 5 8 346mm 15 1 2 394mm 16 1 2 419mm 18 1 16 459mm 19 5 8 498mm 22 3 4 578mm 25 13 16 656mm HEIGHT 16 406mm 19 7 8 505mm 25 11 16 652mm 31 1 2 800mm 43 1 16 1094mm 54 5 8 1387mm 61 7 16 1561mm 65 1 4 1657mm 71 1 16 1805m...

Страница 33: ...31 Figure 31 Figure 32 Straps AC Starter Section AC Chimney Straps Support ...

Страница 34: ...angle for Canada only In cold climate locations we recommend that you use the insulated wall radiation shield since it will maintain the home s thermal barrier RSM and RSMI30 RSMI45 CHIMNEY MODEL ANGLE HOLE SIZE ASHT HT6103 6 dia 30º 283 mm x 781 mm 11 1 8 x 30 Canada only 45º 283 mm x 518 mm 11 1 8 x 20 3 8 S 2100 HT6000 6 dia 30º 327 mm x 881 mm 12 7 8 x 34 11 16 AC 6 dia 30º 380 mm x 972 mm 15 ...

Страница 35: ...wall this support may be used on the wall to support the chimney The maximum heights are given in Table 6 For offset support installation refer to the instructions provided with the support CHIMNEY MODEL MAXIMUM HEIGHT OF SUPPORTED CHIMNEY OFFSET SUPPORT ROOF SUPPORT ASHT HT6103 6 dia 28 ft 8 54m 29 ft 8 84 m S 2100 HT6000 6 dia 18 ft 5 49 m 20 ft 6 1 m AC 6 dia 40 ft 12 19 m 50 ft 15 20 m Table 6...

Страница 36: ...lace is normally supplied with a chimney adaptor suitable for the ASHT HT6103 chimney If you want to install an S 2100 HT6000 chimney an adaptor is available 6UCA figure 35 A separate starter section will also be required if AC chimney is installed Figure 35 ...

Страница 37: ...on where the flue liner will enter the masonry chimney 2 In the middle of the oval drill a hole in the masonry chimney at 45º or 30º 3 Increase the size of the hole until a 45º or 30º Tubinox liner elbow can be easily slipped through 4 Slide the liner down from the top of the masonry chimney until you reach the hole level 5 Slip through the hole a 45º or 30º liner elbow and connect it to the liner...

Страница 38: ...section AC6SB Roof brace XBS2 Wall band XBM Firestop Firestop ACBF Radiation shield ACRS Attic radiation shield ACRSA Wall radiation shield 30º ACRSM30 Insulated wall radiation shield 30º ACRSMI30 Wall radiation shield 45º ACRSM45 Insulated wall radiation shield 45º ACRSMI45 Outside air kit chimney ACZI flex insulation outside register and coupling Flat roof flashing ACF Adjustable roof flashings ...

Страница 39: ... variable speed control with decorative wall plate for BISZY VRUW Thermo disk on off blower control for BISZY VTU Fan to Flexible pipe adaptor BISAVF Heating and cooling thermostat HCTW Back draft damper BISBD Fireplace Rigid fire screen BUCEBWZN Heat activated on off pre wired fan kit included UZY6 Masonry chimney adaptor BISUMA Outside air kit UZI 7 APPENDIX SPECIFICATIONS Weight 385 lbs Height ...

Страница 40: ...PR SR2214 Cast iron log supports 2 PR SR3026 Facing Top trim PR SR3033 Bottom trim PR SR3020 Top frame PR SR2995 Left side frame PR SR2994G Right side frame PR SR2994D Fireplace top PR SR2500 Fireplace left side PR SR2502 Fireplace right side PR SR2503 Fireplace back PR SR2499 Touch up spray paint black SBMB6309 70K99 Wooden door handle PR SR3027 Door rod and lock PR SR2855 Ceramic glass panel PR ...

Отзывы: