21
Facing
1. Combustible wall (such as Gyproc) must be installed flush with the fireplace. It may
not project in front of and on the fireplace (i.e. the steel façade of the fireplace) (figure
15).
2. Decorative frame made of combustible material cannot project in front of and on the
fireplace steel front, in the space delimited by the width of the unit (38") and a height of
54" from the base of the appliance. (Figure 15)
3. Non-combustible materials such as brick, stone or ceramic tile may project in front of
and onto the fireplace facing (figure 14).
Mantel
The mantel must be installed at least 54" (1372 mm) above the base of the fireplace
(figure 13). The shelf may be lowered to 48 inches if the upper panel is blocked by the
panel for clean face option (BPCF) and that hot air gravity ducts are used (7B30ZR-1).