15
ALWAYS
Turn off, Unplug From Power Source and Perform Lockout/Tagout Procedure to This
Machine
BEFORE
Servicing.
NEVER
Touch This Machine Without Training and Authorization By Your Supervisor.
NEVER
Bypass, Alter, or Modify This Equipment in Any Way From Its Original Condition.
PROMPTLY REPLACE
Any Worn of Illegible Labels.
USE ONLY GENUINE BIRO
Parts and Accessories Properly Installed.
A. PUMP FILTER
1. Check filter daily. Filter must be drained before the separated moisture and oil reaches the bottom of the
lower white element. Drain by unscrewing the black drain plug in bottom of sight bowl.
2. The filter element should be removed and cleaned monthly.
a. Unscrew clear threaded bowl.
b. Unscrew filter element assembly.
c. Clean bowl and filter element. Reassemble filter element. Clean bowl with mild soap and water only.
Do not use detergents, cleansing agents, such as acetone, alcohol, benzene or gasoline, which are
damaging to plastic.
d. Lubricate bowl gasket to assist initial sealing. Use only mineral based oils or grease. Do not use
synthetic oils or silicones.
e. Screw bowl into body of filter. Close black drain plug.