Birko USB 2.5 Скачать руководство пользователя страница 2

Installation & Operating Instructions

Birko DownUnder Under-Sink Boiling Water

Page 2

 UNDERSINK BOILING WATER

Note:

 Ventilation Buffers

Included in the installation pack are adhesive backed silicon buffers. If air vents are not installed in 
the cupboards housing the Birko unit, the buffers must be placed on the inside edge of the cupboard 
door to create a slight gap ensuring a minimum airflow. Failure to do this may cause the Birko unit to 
overheat and operate inefficiently.

Water Supply

The system is designed to be connected to a cold water supply via

1) a filter (provided), 

2) a pressure limiting valve (not provided) and 

3) an isolating valve (not provided).

Never connect this system  to a hot water or warm water supply.

Minimum operating pressure is 200 kPa and maximum of 800 kPa. 

Cold water supply temperature should range only from 5°C to 30°C.

Do not use sealing paste on water supply joints as it may taint water.

Plumbing

Do not remove the cover of the under-sink unit during installation.

All connections can be accessed from the top of the unit without removing the cover.

To install the tap, first cut a 22 mm diameter hole in the sink.

Position the tap so the spout drains directly into the sink.

For safe operation, position tap button at right angles to spout.

Pass the tap hose and cable through hole to under-sink unit.

Clamp tap base in position using plastic nut and washer provided.

Install the safe tray (provided) in the cupboard beneath the tap.

Place the under-sink unit in position within the safe tray.

Trim the tap hose to length and fit to the under-sink unit outlet.

Do not coil, kink or extend the tap hose connected to the outlet.

Connect the low voltage cable from the tap to the under-sink unit.

Do not cut the cable: excess cable must be coiled and tied off.

Tap

Button

Valve

Filter

Tray 

Cable

Hose

Power