Safety Precautions

The following are general safety precautions that are not necessarily related to any specific part or procedure and do not
necessarily appear elsewhere in this publication. These precautions must be thoroughly understood and apply to all phases
of operation and maintenance.

Keep Away From Live Circuits

Operating personnel must at all times observe general safety precautions. Do not replace components or make adjustments
to the inside of the test equipment with the high voltage supply turned on. To avoid casualties, always remove power.

Do Not Service Or Adjust Alone

Under no circumstances should any person reach into an enclosure for the purpose of service  or adjustment of equipment
except in the presence of someone who is capable of rendering aid.

Safety Earth Ground

An earth uninterruptible safety ground must be supplied from the main power source to test instruments. Grounding one
conductor of a two conductor power cable is not sufficient protection. Serious injury or death can occur if this grounding
is not properly supplied.

Shock Hazard

Do not attempt to remove RF transmission line while RF power is present.

Chemical Hazard

Dry cleaning solvents used to clean parts may be potentially dangerous. Avoid inhalation of fumes and also prolonged
contact with skin.

Resuscitation

Personnel working with or near high voltages should be familiar with modern methods of resuscitation. Such information
may be obtained from the Bureau of Medicine and Surgery.

Safety Symbols

WARNING

 Warning notes call attention to a procedure, which if not correctly performed, could result in personal injury.

CAUTION

Caution notes call attention to a procedure, which if not correctly performed, could result  in damage to the instrument.

This symbol appears on the equipment indicating there is important information in the instruction manual regarding

that particular area. See page 24 for specific caution.

3

Содержание Wattcher 3126A

Страница 1: ...TH PARTS LIST WATTCHER MONITOR ALARM MODELS 3126A 3127A 3128A Copyright 1996 by Bird Electronic Corporation Instruction Book Part Number 920 3126 27 28A Revision A Thruline and Wattcher are registered...

Страница 2: ...for amounts so expended by Buyer Every such claim for breach of these warranties shall be deemed to be waived by Buyer unless made in writing within ten 10 days from the date of discovery of the defe...

Страница 3: ...he main power source to test instruments Grounding one conductor of a two conductor power cable is not sufficient protection Serious injury or death can occur if this grounding is not properly supplie...

Страница 4: ...hazard 3126A 27A 28A Caution Statements The following equipment cautions appear in the text whenever the equipment is in danger of damage and are repeated here for emphasis CAUTION Be sure voltage sel...

Страница 5: ...uctions necessary to operate the equipment are contained in this section Maintenance All personnel should be familiar with preventive maintenance found in Chapter 5 Maintenance If a failure should occ...

Страница 6: ...eory of Operation 11 Chapter 3 Installation 15 Items Required 15 Chapter 4 Operations 17 General 17 Zero Adjust 17 Alarm Enable Disable 17 Fail Safe Non Fail Safe Mode 17 Adjusting Reflected Power Tri...

Страница 7: ...for the protection and monitoring of radio frequency transmission systems The line section is selected to be compatible with the RF coaxial line used in the transmission system The elements are selec...

Страница 8: ...ch Alarms Audible buzzer and visual front panel LED Alarm Actuation Time 50ms typical Finish Light navy gray powder coat Nominal Size 19 X 5 7 32 X 3 3 4 483 X 133 X 95 mm Weight 5 lb 2 28kg Power 115...

Страница 9: ...e LED Green LED when illuminated the alarm is active power is on 4 RFL Alarm LED Red LED flashes when the reflected power trip level has been exceeded for more than 50ms 5 Reset Push button Resets the...

Страница 10: ...n for interlock one 8 COM1 Common Connection for interlock one 9 NC1 Normally closed connection for interlock one 10 NO2 Normally open connection for interlock two 11 COM2 Common Connection for interl...

Страница 11: ...direction in which it is sensing the RF power flow in the system Traveling Wave Viewpoint The best way to visualize the Thruline Wattmeter idea is from the Traveling Wave viewpoint on transmission lin...

Страница 12: ...ition with a spring loaded clasp to keep the element firmly seated The machined step on the top face of the socket engages a stop pin on the element Rotary movement of the element is thereby restricte...

Страница 13: ...e Since there are definite simple relationships between standing wave ratio and the reflected for ward power ratio indicated by the Thruline Wattmeter the latter may be conveniently used to measure VS...

Страница 14: ...Bird Models 3126A 3127A 3128A Wattcher RF Monitor Alarm 14...

Страница 15: ...ling kit is required for connecting the line section to the transmission line The coupling kit will be similar to one of the coupling kits shown below Review the following and refer to the diagram to...

Страница 16: ...d power sensor cables Forward power sensor cable from port A of the line section Reflected power sensor cable from port B of the line section 7 AC line voltage selector switch is in the appropriate po...

Страница 17: ...e mode An interlock active condition can be caused by exceeding reflected power trip value or if the Wattcher Unit is not operating Adjusting Reflected Power Trip Level Ensure that the plug in element...

Страница 18: ...ll scale value shown on the element cap determines the power scale to be read Alarm Condition If the reflected power reading reaches the trip level for longer than 50ms the buzzer will sound if enable...

Страница 19: ...VSWR Conversion Nomograph Chapter 4 Operations 19...

Страница 20: ...VSWR Conversion Nomograph 20...

Страница 21: ...n the measuring positions Any additional elements should be well padded and wrapped before being put in the shipping container Line Section Wrap the connectors on the flanged models with padding and t...

Страница 22: ...or short circuit in dc cable Replace defective dc meter cable RG 58 U Meter burned out or damaged Return Wattcher line section and elements to the factory for meter replacement and calibration Intermi...

Страница 23: ...al health hazard Inspection Inspect the Wattcher Unit cleanliness proper adjustment and with the RF power removed check the ZERO setting and adjust if necessary Preventive Maintenance The element sock...

Страница 24: ...maintained If the spring finger of the dc contact requires adjustment it may be done manually if carried out with care The tip must be positioned far enough out to maintain good contact with the elem...

Страница 25: ...ransformer 5A2309 8 1 AC power input receptacle 5A2297 1 J4 Remote terminal plug connector 4 contacts 5A2075 4 1 J5 Interlock terminal plug connector 6 contacts 5A2075 6 2 J1 J2 BNC connectors 5A2319...

Страница 26: ...Record model and serial numbers located on back panel MODEL NUMBER SERIAL NUMBER Bird Models 3126A 3127A 3128A Wattcher RF Monitor Alarm 26...

Отзывы: