BIRD Thruline 4304A Скачать руководство пользователя страница 34

24

Limited Warranty

All products manufactured by Seller are warranted to be free from defects in 
material and workmanship for a period of one (1) year, unless otherwise 
specified, from date of shipment and to conform to applicable specifications, 
drawings, blueprints and/or samples. Seller’s sole obligation under these 
warranties shall be to issue credit, repair or replace any item or part thereof 
which is proved to be other than as warranted; no allowance shall be made for 
any labor charges of Buyer for replacement of parts, adjustment or repairs, or 
any other work, unless such charges are authorized in advance by Seller.

If Seller’s products are claimed to be defective in material or workmanship or 
not to conform to specifications, drawings, blueprints and/or samples, Seller 
shall, upon prompt notice thereof, either examine the products where they are 
located or issue shipping instructions for return to Seller (transportation-
charges prepaid by Buyer). In the event any of our products are proved to be 
other than as warranted, transportation costs (cheapest way) to and from 
Seller’s plant, will be borne by Seller and reimbursement or credit will be made 
for amounts so expended by Buyer. Every such claim for breach of these 
warranties shall be deemed to be waived by Buyer unless made in writing within 
ten (10) days from the date of discovery of the defect.

The above warranties shall not extend to any products or parts thereof which 
have been subjected to any misuse or neglect, damaged by accident, rendered 
defective by reason of improper installation or by the performance of repairs or 
alterations outside of our plant, and shall not apply to any goods or parts 
thereof furnished by Buyer or acquired from others at Buyer’s request and/or to 
Buyer’s specifications. Routine (regularly required) calibration is not covered 
under this limited warranty. In addition, Seller’s warranties do not extend to the 
failure of tubes, transistors, fuses and batteries, or to other equipment and 
parts manufactured by others except to the extent of the original 
manufacturer’s warranty to Seller.

The obligations under the foregoing warranties are limited to the precise terms 
thereof. These warranties provide exclusive remedies, expressly in lieu of all other 
remedies including claims for special or consequential damages. SELLER NEITHER 
MAKES NOR ASSUMES ANY OTHER WARRANTY WHATSOEVER, WHETHER 
EXPRESS, STATUTORY, OR IMPLIED, INCLUDING WARRANTIES OF 
MERCHANTABILITY AND FITNESS, AND NO PERSON IS AUTHORIZED TO ASSUME 
FOR SELLER ANY OBLIGATION OR LIABILITY NOT STRICTLY IN ACCORDANCE WITH 
THE FOREGOING.

Содержание Thruline 4304A

Страница 1: ...Thruline Wattmeter MODEL 4304A Operation Manual Copyright 2016 by Bird Technologies Inc Instruction Book Part Number 920 4304A Rev F Thruline and Termaline are registered trademarks of Bird Electroni...

Страница 2: ...to remove the RF transmission line while RF power is present WARNING Do Not Service Or Adjust Alone Under no circumstances should any person reach into an enclosure for the purpose of service or adjus...

Страница 3: ...ed here for emphasis WARNING Warning notes call attention to a procedure which if not correctly performed could result in personal injury CAUTION Caution notes call attention to a procedure which if n...

Страница 4: ...EBEN KANN DIE GER TESICHERHEIT BEEINTR CHTIGT WERDEN UTILISATION TOUTE UTILISATION DE CET INSTRUMENT QUI N EST PAS EXPLICITEMENT PR VUE PAR LE FABRICANT PEUT CAUTION Above 800 MHz do not exceed 150 W...

Страница 5: ...s iv ENDOMMAGER LE DISPOSITIF DE PROTECTION DE L INSTRUMENT IMPIEGO QUALORA QUESTO STRUMENTO VENISSE UTILIZZATO IN MODO DIVERSO DA COME SPECIFICATO DAL PRODUTTORE LA PROZIONE DI SICUREZZA POTREBBE VEN...

Страница 6: ...WARTUNG DES GER TES GELTEN NUR F R GESCHULTES FACHPERSONAL ZUR VERMEIDUNG GEF HRLICHE ELEKTRISCHE SCHOCKS SIND WARTUNGSARBEITEN AUSSCHLIE LICH VON QUALIFIZIERTEM SERVICEPERSONAL DURCHZUF HREN ENTRENTI...

Страница 7: ...NT H F CONSERVER L L MENT DANS LA PRISE LORS DE L EMPLOI HF SPANNUNG KANN IN DER HF ELEMENT BUCHSE ANSTEHEN ELEMENT W HREND DES BETRIEBS EINGEST PSELT LASSEN PUEDE HABER VOLTAJE RF EN EL ENCHUFE DEL E...

Страница 8: ...tle page Literature Contents Chapter Layout Introduction Describes the features of the 43 Wattmeter lists equipment supplied and optional equipment and provides power up instructions Theory of Operati...

Страница 9: ...Viewpoint 2 Coupling Circuit 3 Load Power 4 Standing Wave vs Traveling Wave Viewpoint 4 vs Component Testing 7 Impedance Mismatch 8 Chapter 3 Installation 9 Connections 9 Load Matching 9 Chapter 4 Op...

Страница 10: ...line Wattmeter 4304A ix Calibration Checks 19 Setup Test 19 Calibrating a Bird Element 4304A 1 19 Storage 21 Customer Service 21 Specifications 22 Replacement Parts 22 Available QC Type Connectors 23...

Страница 11: ...croammeter is specially shock mounted A screw on the lower front face of the meter is used to zero the pointer Below the meter face the RF line section protrudes slightly from the wattmeter housing wi...

Страница 12: ...voltage Ef and current If in phase with Ef If Zo The reflected wave and its power originates by reflection at the load and travels from the load back to the source It has an RF voltage Er and current...

Страница 13: ...e corresponding capacitive current while thatproducedbythewavetravelingintheoppositedirectionwillsubtract Theadditive or arrow direction is assigned to the forward wave The electrical characteristics...

Страница 14: ...ts drawbacks are that it is usually too long too expensive for good accuracy not portable and too slow These problems grow rapidly as the measurement frequency drops below 1000 MHz The Thruline Wattme...

Страница 15: ...ful approximate picture of the results without bothering to calculate the power ratio exactly Consider that for an antenna matching problem the main objective usually is to minimize Wr Anything done e...

Страница 16: ...RF Directional Thruline Wattmeter 4304A 6 Figure 4 Percent Reflected Power vs VSWR 1 0 8 0...

Страница 17: ...Termaline absorption wattmeter Line loss using open circuit calibration The high directivity of elements can be exploited in line loss measurements by having the load connector open or short circuite...

Страница 18: ...Consider using a Bird 4304A to tune a 70 line If the load impedance is also 70 the wattmeter will measure a VSWR of 70 50 1 4 However if you remove the wattmeter the VSWR will actually be 1 0 Similar...

Страница 19: ...btained removing the wattmeter will not change the match quality A 50 load can terminate a 50 transmission line of any length without altering conditions at the transmitter The wattmeter is just an ad...

Страница 20: ...uency of interest If more than one frequency is involved a separate cable length is required for each See Figure 5 for sample cable lengths Note Cable length is measured from end to end of the outer c...

Страница 21: ...Installation 11 Figure 5 Cable Length Wavelength Matching...

Страница 22: ...on table is located on the back cover plate of the unit Multiply the measured power by the correction factor to determine the actual power VSWR Measurements For your convenience a set of VSWR conversi...

Страница 23: ...Operating Instructions 13 Figure 6 VSWR Conversion Graph Reflected Power 0 2 20 0...

Страница 24: ...RF Directional Thruline Wattmeter 4304A 14 Figure 7 VSWR Conversion Graph Reflected Power 0 01 1 00...

Страница 25: ...ing can be cleaned with a soft cloth dampened with a mild detergent solution Do not wipe the meter glass with a dry cloth or a static charge could develop that would cause an erroneous meter indicatio...

Страница 26: ...ng No RF power Check RF source Arrow on element pointing wrong way Rotate element Meter burned out or damaged Replace the meter Refer to page 18 Intermittent or inconsistent meter reading Dirty DC con...

Страница 27: ...it will need to be returned to a Bird Service Center for recalibration Changing elements without recalibrating will result in inaccurate readings 1 Remove the screw at the lower left corner of the ele...

Страница 28: ...defective return the unit to a Bird Service Center Meter Replacement 1 Use a 5 16 hex wrench to loosen the nuts on the meter terminals Remove the wires from the terminals 2 Remove both screws on the s...

Страница 29: ...the RF source to produce a signal with power in the upper one third of the scale for each power range 3 Compare the reading on the Bird 4304A with the reference wattmeter Note If the unit is outside...

Страница 30: ...4A range switch to 5 10 Divide 50 by the average value calculated in Step 6 then set the RF source to this value at a frequency of 100 MHz 11 Adjust R10 until the 4304A meter indicates 4 0 12 Set the...

Страница 31: ...ce or service procedure beyond the scope of those in this chapter should be referred to a qualified service center If the unit needs to be returned for any reason request an Return Material Authorizat...

Страница 32: ...MHz Accuracy 25 100 MHz 100 512 MHz 512 1000 MHz 7 of full scale with correction factor 6 of full scale 7 of full scale Impedance Nominal 50 Connectors Bird QC Female N or UHF normally supplied Operat...

Страница 33: ...0 N Male 4240 063 HN Female 4240 268 SMA Female 4240 336 HN Male 4240 278 SMA Male 4240 334 LC Female 4240 031 7 16 Jack IEC Type 169 4 4240 344 LC Male 4240 025 7 16 Plug IEC Type 169 4 4240 363 UHF...

Страница 34: ...y such claim for breach of these warranties shall be deemed to be waived by Buyer unless made in writing within ten 10 days from the date of discovery of the defect The above warranties shall not exte...

Отзывы: