BIRD RF Directional Thruline 4028 Series Скачать руководство пользователя страница 2

1

Specifications

CAUTION

Changing the sensor’s connectors will invalidate calibration data, and may 

reduce the maximum power rating of the unit.

Frequency Range

4028A250K 
4028A400K 
4028A2M 
4028A3M 
4028A4M 
4028A10M 
4028A25M
4028A120M 
4028B2M
4028B3M 
4028B10M 
4028C10M

250 – 400 kHz 
400 – 550 kHz 
1.5 – 2.5 MHz 
2.5 – 3.5 MHz 
3.5 – 4.5 MHz 
10 – 15 MHz 
25 – 30 MHz 
110 – 130 MHz 
1.8 – 2.2 MHz
2.5 – 4.0 MHz
10 – 15 MHz 
10 – 15 MHz

RF Power Range

4028A250K 
4028A400K 
4028A120M 
4028B2M
4028C10M 

All other models

1 kW – 20 kW 
1 kW – 20 kW 
0.1 kW– 8.0 kW 
1 kW – 30 kW
500 W – 50 kW 
1 kW – 25 kW

Accuracy, Fwd

At Calibration Frequencies  

and Power Levels

At Other Frequencies and 

Power Levels

 
± 2.0% (2

)

 
± 3.0% (2

)

Accuracy, Reflected

Calculated from FWD accuracy & FWD power

Accuracy, VSWR

Calculated from FWD and RFL power

VSWR, Max.

1.05:1

Insertion Loss, Max.

4028C10M

0.05 dB (with female 7-16 DIN connectors) 
0.05 dB (with 3-1/8 in EIA connector)

Directivity, Min.

28 dB

Accuracy FWD 

Accuracy

FWD Power

10

Directivity 10

/

---------------------------------

+

=

VSWR

1

P

R

P

F

-------

+

1

P

R

P

F

-------

=

Содержание RF Directional Thruline 4028 Series

Страница 1: ...RF Directional Thruline Precision Power Sensors 4028 Series Operation Manual Copyright 2017 by Bird Technologies Inc Instruction Book Part Number 920 4028S Rev H ...

Страница 2: ... MHz 10 15 MHz RF Power Range 4028A250K 4028A400K 4028A120M 4028B2M 4028C10M All other models 1 kW 20 kW 1 kW 20 kW 0 1 kW 8 0 kW 1 kW 30 kW 500 W 50 kW 1 kW 25 kW Accuracy Fwd At Calibration Frequencies and Power Levels At Other Frequencies and Power Levels 2 0 2 3 0 2 Accuracy Reflected Calculated from FWD accuracy FWD power Accuracy VSWR Calculated from FWD and RFL power VSWR Max 1 05 1 Inserti...

Страница 3: ...utput corrected for frequency and temperature within specified ranges Calibration Cycle Nominal 1 year Sampling Rate Nominal 2 readings second Operating Power Supplied by power meter via sensor cable Connectors 4028B10M 4028C10M All other models 1 5 8 EIA Flanged 3 1 8 EIA Flanged Customer specified from 7 16 DIN LC HN and 7 8 flanged appropriate for frequency and power CE CE Compliant Refer to De...

Страница 4: ...8B10M 4028C10M 4028A250K 400K All other models 5 lb 2 oz 2 33 kg 1 lb 13 oz 0 8 kg 3 lb 9 oz 1 6 kg For rated accuracy no more than 1 AM Harmonics 50 dBc or less Derate accuracy by 2 for temperatures outside 25 10 C Other calibration frequencies available upon request ...

Страница 5: ...to apply the Sensor Head must be used with the correct Bird Electronic Corporation Display Unit the maximum power rating of the Sensor must not be exceeded the Sensor RF circuit must be properly terminated and the Sensor not subjected to physical abuse Bird Electronic Corporation at its option will repair or replace the defective Sensor at its world Headquarters at 30303 Aurora Road Solon Ohio 441...