Introduction

2

Equipment Description

Figure

 1 

 

 

Load Protection Switch

Figure

 2 

 

 

Load Protection Switch Schematic

Item

Function

Description

1

Operation 
Indicator

Indicator illuminates green, when the Load 
Protection Switch is closed allowing RF to pass 
through the switch.

2

Flanged Line 
Section

3-1/8 inch Flange on each end of an 8 inch line 
section.

3

Interlock 
Terminal

Interlock terminal provides connection for a two 
wire interlock to control the position of the Load 
Protection Switch.

4

Power Supply 
Input

Input connector for the 24 VDC power supply input.

Содержание 8640A930-1

Страница 1: ...Load Protection Switch Operation Manual Copyright 2019 by Bird Technologies Inc Instruction Book P N 920 8640A930 1 Rev A Thruline is a registered trademark of Bird Electronic Corporation...

Страница 2: ...to remove the RF transmission line while RF power is present WARNING Do Not Service Or Adjust Alone Under no circumstances should any person reach into an enclosure for the purpose of service or adjus...

Страница 3: ...plemental information WARNING Warning notes call attention to a procedure which if not correctly performed could result in personal injury CAUTION Caution notes call attention to a procedure which if...

Страница 4: ...for emphasis On page 3 On page 7 WARNING Leaking RF energy is a potential health hazard Never attempt to connect or disconnect equipment from the transmission line while RF power is being applied Seve...

Страница 5: ...present Ensure actively transmitting components can withstand high levels of reflected power or have a means to stop or lock out transmission if the interlock is inactive CAUTION The Moduload connect...

Страница 6: ...SEGURIDAD DEL INSTRUMENTO BENUTZUNG WIRD DAS GER T AUF ANDERE WEISE VERWENDET ALS VOM HERSTELLER BESCHRIEBEN KANN DIE GER TESICHERHEIT BEEINTR CHTIGT WERDEN UTILISATION TOUTE UTILISATION DE CET INSTRU...

Страница 7: ...S GER TES GELTEN NUR F R GESCHULTES FACHPERSONAL ZUR VERMEIDUNG GEF HRLICHE ELEKTRISCHE SCHOCKS SIND WARTUNGSARBEITEN AUSSCHLIE LICH VON QUALIFIZIERTEM SERVICEPERSONAL DURCHZUF HREN ENTRENTIEN L EMPLO...

Страница 8: ...se send your comments to our Solon Ohio factory This man ual may be periodically updated When inquiring about updates to this manual refer to the part number and revision on the title page Chapter Lay...

Страница 9: ...ription 1 Features 1 Items Supplied 1 Items Required but not Supplied 1 Equipment Description 2 Chapter 2 Installation 3 Unpacking and Inspection 3 Tools Required 3 Mounting the Load Protection Switch...

Страница 10: ...d The Load Protection Switch contains a high voltage relay which is used to open or close the flow of RF through the Switches line section Features Protects Bird Moduloads liquid cooled loads when int...

Страница 11: ...es green when the Load Protection Switch is closed allowing RF to pass through the switch 2 Flanged Line Section 3 1 8 inch Flange on each end of an 8 inch line section 3 Interlock Terminal Interlock...

Страница 12: ...damaged unpack the unit Save shipping materials for repackaging 2 Inspect unit for visual signs of damage Note If there is damage immediately notify the shipping carrier and Bird Technologies Tools Re...

Страница 13: ...er direction 1 Insert the center connector bullet Note Push the connector until it is fully seated 2 Connect the coaxial input in a straight line Note Push carefully to close 3 Insert the bolt sets 4...

Страница 14: ...cover from the Load Protection Switches interlock terminal 3 Connect one end of the interlock wires to the Load Protection Switch s terminal strip 4 Install the terminal s protective cover Figure 4 Te...

Страница 15: ...down the transmission line Normal Operation Note Hot switching i e activating the RF switch with RF power present in the transmission line is not recommended 1 Check the Interlock connection between...

Страница 16: ...ms which can occur during normal operation This manual cannot list all malfunctions that may occur or their corrective actions If a problem is not listed or is not corrected by the listed actions noti...

Страница 17: ...39 2794 Fax 440 248 5426 E mail bsc birdrf com For the location of the Sales Office nearest you visit our Web site at http www birdrf com Frequency Range 1kHz to 120MHz Insertion Loss Values are with...

Страница 18: ...such claim for breach of these warranties shall be deemed to be waived by Buyer unless made in writing within ten 10 days from the date of discovery of the defect The above warranties shall not exten...

Страница 19: ......

Отзывы: