TX RX Systems Inc. Manual 7-9322-5 08/09/06 Page 20
SYSTEM STATUS MONITORING
The system continuously monitors the current being
drawn by all three amplifiers, and reveals the status
of the amplifiers in three ways: LCD Display, status-
indicator LEDs and Form-C contacts (“screw termi-
nals”).
Table 7
summarizes the status of the LEDs
and Form-C contacts for various amplifier condi-
tions.
LCD Display
The LCD display provides an indication of the rela-
tive current being drawn by all of the three system
amplifiers. Typical displayed values for each of the
system amplifiers is listed in
Table 8
. By pressing
the front panel SELECT switch the display will show
the amount of MAIN and BASE attenuation that has
been programmed into the system.
N OTE:
Dep en di ng o n c om po nen t
availability two slightly different amplifi-
ers can be used in the tower top box,
either 3-18941 or 3-19285. The only
functional difference between the two
amplifiers is the normal current draw
level as shown in table 8.
Status-Indicator LEDs
Status-indicator LEDs for all three amplifiers illumi-
nate in one of three colors. The meaning of each
color is summarized on the front panel of the MCA
and in table 7. During normal operation, the LEDs
for amplifier A and the BASE amplifier will glow
bright green, indicating normal current draw. The
LED for amplifier B will glow a dull green.
Form-C Contacts
ALARM and WARNING Form-C relay contacts are
located at the back of the MCA (see figure 8).
These screw terminals are intended for connection
to the customer’s supervisory and data acquisition
system.
NOTE
Amplifier
Displayed Value
Amp A (part# 3-18941)
285-435
Amp A (part# 3-19285)
450-600
Amp B (part # 3-18941)
285-435
Amp B (part# 3-19285)
450-600
Base Amp
610-760
Table 8:
Typical current readings.
LED
Possible Amplifier Status
Form-C Contact Status
Amplifier A
Bright green
Selected
; normal current
Normal
Dull green
Not selected
; normal current
Normal
Orange
Warning:
Abnormal current; can only be selected if amplifier B is in
Warning or Alarm
Warning contacts change state
Red
Failure:
Very abnormal current; can only be selected if amplifier B is
in Alarm
Alarm contacts change state
Red
Failure:
Extremely abnormal current; cannot be selected
Alarm contacts change state
Amplifier B
Bright green
Selected:
normal current
Normal
Dull green
Not selected
; normal current
Normal
Orange
Warning:
Abnormal current; can only be selected if amplifier A is in
Warning or Alarm
Warning contacts change state
Red
Failure:
Very abnormal current; can only be selected if amplifier A is
in Alarm
Alarm contacts change state
Red
Failure:
Extremely abnormal current; cannot be selected
Alarm contacts change state
Base Amplifier
Bright green
Normal current
Normal
Orange
Warning
: Abnormal current
Warning contacts change state
Red
Failure
: Very abnormal current
Alarm contacts change state
Table 7:
LED and alarm troubleshooting guide.