Directional Power Sensor 4043

v

About This Manual

This manual covers the operating and maintenance instructions for the 
following models:

Changes to this Manual

We have made every effort to ensure this manual is accurate. If you discover 
any errors, or if you have suggestions for improving this manual, please send 
your comments to our Solon, Ohio factory. This manual may be periodically 
updated. When inquiring about updates to this manual refer to the part number 
and revision on the title page.

Chapter Layout

Introduction  — 

Describes the features of the 4043 Directional Power Sensor.

Installation — 

Describes how to set up and prepare the 4043 Power Sensor 

for use.

Maintenance — 

This section provides the specifications for the 4043 Power 

Sensor as well as a model identification table. 

4043 Series - Directional Power Sensors

Содержание 4043

Страница 1: ... Power Sensor Model 4043 Operation Manual Copyright 2019 by Bird Technologies Inc Instruction Book Part Number 920 4043 Rev E The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG Inc ...

Страница 2: ...o remove the RF transmission line while RF power is present WARNING Do Not Service Or Adjust Alone Under no circumstances should any person reach into an enclosure for the purpose of service or adjustment of equipment except in the presence of someone who is capable of rendering aid WARNING Safety Earth Ground An uninterruptible earth safety ground must be supplied from the main power source to te...

Страница 3: ...s 3 and 7 WARNING Warning notes call attention to a procedure which if not correctly performed could result in personal injury CAUTION Caution notes call attention to a procedure which if not correctly performed could result in damage to the instrument WARNING Leaking RF energy is a potential health hazard Never attempt to connect or disconnect equipment from the transmission line while RF power i...

Страница 4: ...N DE SEGURIDAD DEL INSTRUMENTO BENUTZUNG WIRD DAS GERÄT AUF ANDERE WEISE VERWENDET ALS VOM HERSTELLER BESCHRIEBEN KANN DIE GERÄTESICHERHEIT BEEINTRÄCHTIGT WERDEN UTILISATION TOUTE UTILISATION DE CET INSTRUMENT QUI N EST PAS EXPLICITEMENT PRÉVUE PAR LE FABRICANT PEUT ENDOMMAGER LE DISPOSITIF DE PROTECTION DE L INSTRUMENT IMPIEGO QUALORA QUESTO STRUMENTO VENISSE UTILIZZATO IN MODO DIVERSO DA COME SP...

Страница 5: ...GERÄTES GELTEN NUR FÜR GESCHULTES FACHPERSONAL ZUR VERMEIDUNG GEFÄHRLICHE ELEKTRISCHE SCHOCKS SIND WARTUNGSARBEITEN AUSSCHLIEßLICH VON QUALIFIZIERTEM SERVICEPERSONAL DURCHZUFÜHREN ENTRENTIEN L EMPLOI DES INSTRUCTIONS D ENTRETIEN DOIT ÊTRE RÉSERVÉ AU PERSONNEL FORMÉ AUX OPÉRATIONS D ENTRETIEN POUR PRÉVENIR UN CHOC ÉLECTRIQUE DANGEREUX NE PAS EFFECTUER D ENTRETIEN SI L ON N A PAS ÉTÉ QUALIFIÉ POUR C...

Страница 6: ...send your comments to our Solon Ohio factory This manual may be periodically updated When inquiring about updates to this manual refer to the part number and revision on the title page Chapter Layout Introduction Describes the features of the 4043 Directional Power Sensor Installation Describes how to set up and prepare the 4043 Power Sensor for use Maintenance This section provides the specificat...

Страница 7: ...l Communication Model 2 Serial Communication Power Sensor Installation 3 Chapter 3 Bluetooth Communication Model 5 Bluetooth Communication Model Installation 7 Pairing the 4043 Bluetooth Sensor with the Bird RF Meter App 7 Bluetooth Power Sources 8 Internal Battery Operation 8 External Power Supply Cable Assembly 8 Chapter 4 Maintenance 9 Customer Service 9 Chapter 5 Specifications 10 Model Identi...

Страница 8: ...0 MHz See Model Identification on page 12 for specific frequency ranges and model features The 4043 sensor also provides a VSWR reading Figure 1 4043 Power Sensor The model 4043 power sensor is available with two different types of communication interface RS 485 Serial Communication designed for use with the Bird Channel Power Monitor CPM in rack mounted communications systems See Serial Communica...

Страница 9: ...to be connected serially each one is assigned a unique address via the CPM When each 4043 is connected to the CPM prior to connecting any additional 4043 sensors they must be assigned an address by the CPM only then may an additional sensor be connected serially A termination plug must be used in the open RJ 25 jack on the rear panel of the CPM or the open RJ 25 jack of the final digital sensor in...

Страница 10: ...2 Connect combiner s RF output cable to the 4043 RF input Figure 3 CPM RS 485 Serial Connection Diagram 3 Connect 4043 s RF output connector to the antenna cable 4 Repeat step 1 through 3 for any additional 4043 power sensors 5 Install RJ 25 termination plug in unused digital sensor RJ 25 port on the rear panel of the CPM if available or in the last sensor installed in the digital sensor chain 6 C...

Страница 11: ...al 8 If additional 4043 power sensors will be connected connect a data power cable to the open RJ 25 jack connect remaining end of cable to additional 4043 sensor 9 Repeat step 7 and 8 for any additional 4043 power sensors serially connected to the CPM Note Digital sensors require a terminator plug be installed in the open Digital Sensor RJ 25 port on the rear panel of the CPM if available or in t...

Страница 12: ... available see Model Identification on page 12 RF Output N Type female connector shown other connector types available see Model Identification on page 12 Battery Compartment Batteries are the primary source of power for the Bluetooth model 4043 power sensor Three AAA batteries are required Auxiliary Power Connectors RJ 25 connectors are provided for an auxiliary power supply source A cable may be...

Страница 13: ...ower supply 12 VDC nominal 7 18 VDC minimum 50 mA to RJ25 Power may be supplied from an external DC power supply through the RJ 25 jack See Bluetooth Power Sources on page 8 Note This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interf...

Страница 14: ...heading 7 Tap the 4043 sensor listed under Found Devices The App should connect to the device and display the sensor current measurement readings Note Use the RF Meter App s Help content for instructions on how to configure the App and sensor Pairing the 4043 Bluetooth Sensor with the Bird RF Meter App First time pairing of a 4043 Sensor and a device running the Bird RF Meter App is accomplished b...

Страница 15: ... on page 9 External Power Supply Cable Assembly Note This assembly is not required if internal batteries are supplying power to the 4043 Bluetooth Sensor 1 Using suitable wire connect the power supply to an RJ 25 plug a Connect the positive 12 VDC 7 18 VDC supply output wire to pin 1 of the RJ 25 plug and the ground wire to pin 2 see Figure 5 2 Insert the RJ 25 plug into either RJ 25 connector on ...

Страница 16: ...procedure beyond the scope of those in this chapter should be referred to a qualified service center If the unit needs to be returned for any reason request an Return Material Authorization RMA through the Bird Technologies website All instruments returned must be shipped prepaid and to the attention of the RMA number Bird Service Center 30303 Aurora Road Cleveland Solon Ohio 44139 2794 Fax 440 24...

Страница 17: ...cy 5 of reading Data Interfaces Model Dependent See Model Identification on page 12 RS 485 Serial Interface Bluetooth1 RS 485 Data Interface Connector RJ 25 Power Supply Requirements DC RJ 25 Jack CPM or External P S Battery Operation 7 18 VDC 50 mA 3 AAA size alkaline batteries Operating Temperature Range 0 C to 50 C 32 F to 122 F Storage Temperature Range 40 C to 80 C 40 F to 176 F Humidity 95 m...

Страница 18: ...airs and Communications MIC of Japan pursuant to the Radio Act of Japan BMD 300 210 106799 BMD 301 210 107153 BMD 350 210 108944 Australia New Zealand AS NZS 4268 2012 AMDT 1 2013 Radio equipment and systems Short range devices Bluetooth BMD 300 301 RF PHY Component Tested DID D030629 QDID 81876 1 This device complies with part 15 of the FCC rules Operation is subject to the following two conditio...

Страница 19: ...Specifications 12 Model Identification 0 1 2 3 4 5 6 7 5 6 8 9 456 7 8 9 456 ...

Страница 20: ...Directional Power Sensor 4043 13 ...

Страница 21: ...ry such claim for breach of these warranties shall be deemed to be waived by Buyer unless made in writing within ten 10 days from the date of discovery of the defect The above warranties shall not extend to any products or parts thereof which have been subjected to any misuse or neglect damaged by accident rendered defective by reason of improper installation or by the performance of repairs or al...