13
Chapter 5
Maintenance
Troubleshooting
The table below contains troubleshooting information for problems
which can occur during normal operation. This manual cannot list all
malfunctions that may occur, or their corrective actions. If a problem
is not listed or is not corrected by the listed actions, notify a qualified
service center.
Maintenance
Cleaning
The outside surface of the unit should be wiped free of dust and dirt
when necessary. Clean the RF connector, both metallic and insulating
surfaces, with a dry, non-residue forming solvent.
If the optional water flow switch is installed, periodically remove it
from the load and clean off any dirt or scale which might prevent the
switch from functioning.
Problem
Possible Cause
Correction
Transmitter won’t turn on or
shuts off repeatedly
Overheating
Increase water flow
Lower the ambient temperature
Insufficient water flow
Check the coolant circulation system
Excessive reflected power
DC resistance of the load has
changed
Check DC resistance (see “DC
Resistance” on page 14)
Contaminated water
Check the resistor for scaling. Replace if
necessary.
Check that the water meets the standards
listed in the specifications. Use distilled
water if necessary.
WARNING
Disconnect the unit from all power sources before servicing.
The unit may be energized from multiple sources.
The potential for electric shock exists.