![Bird Electronic Econoload 8730 Series Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/bird-electronic/econoload-8730-series/econoload-8730-series_instruction-book_2756581024.webp)
Bird 8730 Series Econoload RF Load Resistor
14
Inspection
Routinely inspect the following components:
y
Load: Check the center and outer conductors for visible damage or
excessive wear
y
Hoses: Check for cracks or deterioration. Make sure the hoses are
securely fastened to the load.
DC Resistance
Measuring the dc resistance between the inner and outer conductors
of the RF connector shows changes in the load over time, a good check
of the resistor’s condition. Under normal operating conditions, the
resistor should provide at least 5,000 hours of operation before
requiring any additional service. DC resistance tracking must start
before the load is put into service, and should be measured annually.
Perform the following steps and record the value for future
comparison. Make sure that you have an ohmmeter with an accuracy
of ±1% at 50 ohms and that the load temperature is between 20 and
25 °C (68 to 77 °F) before starting.
y
Turn off the RF power and interlock circuitry.
y
Disconnect the RF line.
y
Connect the multimeter test leads to the center and outer
conductor of the load. Refer to Figure 6.
y
Compare the measured value with the previous measurement and
with the baseline resistance, measured when the load was put
into service. If the new value differs from either of these by more
than 2 ohms this could indicate a failing resistor.
Figure 6
Measuring
Resistance
WARNING
Never attempt to connect or disconnect RF equipment from the
transmission line while RF power is being applied.
Leaking RF energy is a potential health hazard.