background image

Radarfield

a

b

ArtMotion 2

ArtMotion 2

3 m

+

– +

+

 –

1m

2m

3m

1m

2m

0m

0m

1m

2m

3m

4m

2.2 m

90°

1m

2m

3m

1m

2m

0m

0m

1m

2m

3m

4m

2.2 m

1

a

Art

Motion 2 

Connecting

Observe the national and international regulations on door safety.

Only trained, qualified personnel may mount and start up the detector.

The unit may only be opened and repaired by Bircher Reglomat.

The unit may only be operated from a safety extra-low voltage (SELV) system with safe electrical separation.

Always consider the safety functions of your application as a whole, never just in relation to one individual section of the system. 

The installer is responsible for carrying out a risk assessment and installing the detector and the door system correctly.

Avoid touching any electronic components.

The door drive and transom profile must be earthed correctly.

Start-up

2

Montage

Original instructions

Recommended start-up sequence:

     

I. Mounting      II. Connection

    Mounting

I

General

Safety instructions

1

1.

 Remove cover hood  

2.

 Lay and connect cable 

3.

 Mount detector 

Microwave motion detector for opening  

automatically controlled doors   

1.

 Position drill template 

2.

 Drill the holes, remove drill template

3. 

Lay cable and mount detector

ENGLISH

Mounting of the detector

II

Electrical connections

3

Mechanical fine tuning

4

Wide radar field

min. = 0.8 x 1.6 m 

max. = 2.3 x 4.8 m (WxD)

Inclination angle: 35°

Inclination angle: 35°

Radar field

Hood  

Light window detector indication  

 

Cable bushing

  

 

Mounting

 

 

Microwave module

 

 

LED microwave: green

 

 

Potentiometer

min. = 1.6 x 0.8 m

max. = 4.8 x 2.3 m (WxD)

turn

 

90°

Narrow radar field

351084A

12/15

Controller

Power

Supply

Radar 

output

Radar

white

brown

white

green

Cable

yellow

brown

green

yellow

Manual settings of the  

inclination

0° ... +45° in 5° steps

12–36 VDC 

12–28 VAC