background image

1 Cover frame
2 Front lens cap

2a

2b

2c

1

2

3 4

5

6

7

8

9

Proxy

Switch

presence

Touchless Push Plate 

Questions? Call us at 800 - 252-1272, 8am - 5pm central standard time.

1

Safety Instructions

* The device must only be operated at a protective low voltage with safe electrical insulation. 

* Product repairs must be performed solely by the manufacturer.

* Shut off all power going to the sensor before attempting any wiring procedures.

* Maintain a clean & safe environment when working in public areas.

* Constantly be aware of pedestrian traffic around the door area.

* Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door.

* Always check placement of all wiring and components before powering up to ensure that moving door parts will not catch any  

wires and cause damage to equipment.

* Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation.

D O   N O T   L E A V E   A N Y   P R O B L E M S   U N R E S O L V E D   -   N E V E R   S A C R I F I C E   S A F E T Y   F O R   A N Y   R E A S O N

3 Jumper scanning ranges
4 Connection terminal
5 Jumper scanner/switch ON/OFF

6 Pot. scanning range setting
7 Transmitter
8 Receiver
9 Function indication red LED

2

Design / Overview

Surface mounting use accessory PRSW-SMB

3

Mounting / Installation

User s guide

,

IMPORTANT:      WHEN CONNECTING THE DEVICE TO THE OPERATING VOLTAGE, NO OBJECT MAY BE IN THE DETECTION AREA.