Loop detector for industrial doors and gates and car parks

Translation of the original instruction

General

1

Safety instructions

3

Connect electrical equipment

2

Mechanical mounting in the switch cabinet

En

GL

iS

h

354822B

06/16

i

  Information – light emitting diode

  LCD display

  “Mode” key

  “Data” key

  Connecting terminals

  Type plate

–  These devices and their accessories may only be operated in accordance 

with the operating instructions (intended use).

–  These devices and their accessories may only be placed in operation by 

trained and qualified personnel.

–  These devices may only be operated with the operating voltages and

parameters intended for them.

–  If malfunctions occur that cannot be eliminated, place the device out of

operation and send it in for repair.

–  These devices may only be repaired by the manufacturer. Tampering and 

alterations are not permitted. This will invalidate all guarantee and war-
ranty claims.

The ProLoop Lite is mounted in the switch cabinet on a 35 mm H-rail in accordance with EN 50022. The terminals can be plugged in and coded. 

The loop connection wiring to a loop detector must be twisted at least 20 times per meter.
Please wire the device according to the wiring diagram.
Ensure correct assignment of the terminals and that the power supply is right in accordance with the type plate on the device.

Power supply

Loop connection 
1-channel device

Loop connection 
2-channel device

Output 1

Output 2

˜⁄

+

˜⁄

A1
A2

L3
L4

L3
L4
L5
L6

1

2

14

11
12

no

nc

common

24

21
22

no

nc

common

4

Value and parameter setting options

General

The settings of the ProLoop Lite devices in this chapter are depicted and explained using the 1-loop device.  
The settings for loop 2 of a 2-loop device should be made using the corresponding method. 

3.1

Terminal connection diagram