PrimeMotion C
a
c
b
Radarfeld
f
e
d
g
e
e
d
h
Connecting
1
Prime
Motion
C
Observe the national and international regulations on door safety.
Only trained, qualified personnel may mount and start up the detector.
The unit may only be opened and repaired by Bircher Reglomat.
The unit may only be operated from a safety extra-low voltage (SELV) system with safe electrical separation.
Always consider the safety functions of your application as a whole, never just in relation to one individual section of the system.
The installer is responsible for carrying out a risk assessment and installing the detector and the door system correctly.
Avoid touching any electronic components.
The door drive and transom profile must be earthed correctly.
Start-up
2
Montage
Translation of the original instructions
Recommended start-up sequence:
I. Mounting II. Connection
Mounting
I
General
Safety instructions
1
1.
Remove cover hood
2.
Lay and connect cable
3.
Mount detector
Microwave motion detector for opening
automatically controlled doors
1.
Position drill template
2.
Drill the holes, remove drill template
3.
Lay cable and mount detector
ENGLISH
Mounting of the detector
II
Electrical connections
3
+
Mechanical fine tuning
4
– +
Manual settings of the
inclination
0° ... +45° in 5° steps
Manual settings of the
pivoting
– 20° ... +20° in 5° steps
–
+
1m
2m
3m
1m
2m
0m
0m
1m
2m
3m
4m
Wide radar field
min. = 0.8 x 1.6, max. = 2.3 x 4.8 m (WxD)
+
–
–
Inclination angle: 35°
Inclination angle: 35°
1m
2m
3m
1m
2m
0m
0m
1m
2m
3m
4m
2.2 m
2.2 m
–
b
a
90°
PrimeMotion C
Controller
white
brown
green
yellow
white
Power
Supply
Potential-
free
output
12–36 VDC
12–28 VAC
GND
+
Controller input
brown
green
yellow
Cable
3m
Low Active
PrimeMotion C
Controller
white
brown
green
yellow
white
Power
Supply
Potential-
free
output
12–36 VDC
12–28 VAC
GND
Controller input
brown
green
yellow
Cable
3m
+
High Active
Radar field
a
Hood
b
Light window detector indication
c
no function
d
Cable bushing
e
Mounting
f
Microwave module
g
LED microwave: green
h
Potentiometer
min. = 1.6 x 0.8, max. = 4.8 x 2.3 m (WxD)
turn
90°
Narrow radar field
298506E