MAINTENANCE
●
Daily Maintenance
●
Take the two screws then wash the fan cover
●
After working for some time, dust will clog the stainless steel fence which is used to filter the air,
causing insufficient heat dissipating and damaging the equipment. Periodically wash, once every two
weeks as necessary. In clean environments, the period between cleaning can be longer.
●
Special reminder : normally, the generator tube cannot be opened or cleaned. If the generator
cannot work because of an abnormal operation or installation, our company will not take
maintenance responsibility. Be sure that you have enough professional technique before cleaning,
otherwise, please contact your local distributor or after sale service department of our company.
●
If an unclean air source is input or the equipment has been working for more than 12 months, there
may be dust attached on the surface of the discharge tube inside the discharge chamber, which will
clog discharge space and lead to insufficient discharge, causing yield of ozone drop. Then the ozone
generator tube should be cleaned.
●
Cleaning method: Dismantle generator tube 18; input cleaning liquid (such as all purpose cleaner /
dishwashing liquid) input washing water with some pressure repeatedly till clean, then dry.
GENERATOR IMAGE AND INSTRUCTION WITH INTERNAL HEATING AND DRYING TUBE
Notice: The heating and drying tube will be included only according to your requirement at an extra cost. The
standard ozone generator does not include the heating and drying tube.
Picture 8 Instruction of Product with heating and drying tube
10