background image

 

Location 

Place the device as high as possible, preferably in the ceiling. If it is not 
possible because of very high ceilings, the device is placed approximately 50 
cm above the source of the problem / smell. 
Please place the unit at a ventilator with supply air for maximum circulation of 
the photoplasm. (no demand) 
Do not place the unit at the exhaust air valve. 
After mounting the bottom plate on the wall or ceiling, fasten the cover. 
You press down the key in the hole in the middle and turn a 

¼

 turn clockwise to 

put the device on, while closing the closure cover. Remove the key and store in 
the appropriate location. 

 
 
Maintenance 
AirCare

 does not require much maintenance. If the device is in a very smoky 

or dusty environment, we suggest you open the device and clean the UV lamp 
with some alcohol (every 3 months). If you do not clean the lamp, the cleaning 
effect is gradually reduced. If the device isplaced in a garbage room, it may be 
good to clean inside and outside the unit once a month. It may also be good to 
cover the sides with a piece of cloth if there are a lot of flies and / or dust. 
 

Replacing the lamp 

After approximately 1 year of continuous operation (2 years if the device is 
used occasionally) the power of the UV lamp decreases and it needs to be 
replaced. 
 
Press down the key and turn it counterclockwise 

¼

 lap, to turn off the unit (off) 

and unlock (open) the cover. Remove the key and gently bolt with a 
screwdriver or the end of the key between the bottom plate and the cover. 
Remove the cover. All electronics are located on the bottom plate. 
Replace lamp (use only BioZone original lamp, use of other lamp will cancel 
warranty) 
Replace the cover (important to get it right - read inside the cover), plug in and 
start the device, by pressing down the key and turn it clockwise 

¼

 lap .  

Check that the UV light is on (blue shine)?  
Note! Environmentally hazardous waste! The lamp is thrown in containers 
intended for lamps containing mercury. 

BioZone Portugal, Lubelias, 

www.biozone.one,  +351 92 422 98 45

 

Practical information 

Содержание AirCare Series

Страница 1: ...creeps or winds Applications BioZone AirCare is installed in garbage disposal facilities and effectively replaces cooling devices at a fraction of the cost BioZone AirCare is installed in creeps or on winds and detoxifies mold spores and effectively prevents new mold growth BioZone AirCare is installedion public toilets with odor problems 1 BioZone Portugal Lubelias www biozone one 351 92 422 98 4...

Страница 2: ...m 1 unit of AirCare 30 up to 150 sqm Applications Cold Room The constant humid air in the cold rooms is a ground for mold BioZone air purifier effectively stops mold spores and mold growth in cold storages Garbage Disposal Facilities BioZone effectively stops bad odors in the garbage disposal facilities You can save up to 1700 year and washroom by switching from cooling devices to BioZone air puri...

Страница 3: ...OC volatile chemical gases and neutralizes bad odors The plasma that is the ultra air is then blown back into space and brings with it the purifying photoplasma that seeks and destroys harmful pollutants at the molecular level in all areas Compared with passive air purification systems which only can filter out contaminants and pollutants using a fan an air purification systems based on plasma tec...

Страница 4: ...le clean the bedroom during the day and turn off the unit at night Then you get clean air before the night but do not risk being sensitive to the ozone This applies to a very small part of the population Most people only feel good about the small level of ozone we produce in connection with our photocatalytic purification process It is the same level as you can find outdoors on a regular sunny sum...

Страница 5: ...n a garbage room it may be good to clean inside and outside the unit once a month It may also be good to cover the sides with a piece of cloth if there are a lot of flies and or dust Replacing the lamp After approximately 1 year of continuous operation 2 years if the device is used occasionally the power of the UV lamp decreases and it needs to be replaced Press down the key and turn it counterclo...

Страница 6: ...cumulation will not exceed 0 04 ppm if the device is used according to instructions Ion Generation Photo ionization of negative ions Material ABS Aluminium Composite Electrical input 12 V DC Temperatures between 20 degrees Celcius to 40 degrees Celsius Manufacturing Made in China EPA approved factory Warranty 1 year Practical information BioZone Portugal Lubelias www biozone one 351 92 422 98 45 ...

Страница 7: ...damage caused by lightning strikes If you have any problems contact us at 351 92 422 98 45 or via the website www biozone one 7 BioZone Portugal Lubelias www biozone one 351 92 422 98 45 Warranty Before you may return your BioZone we would like you to investigate the following The fan works but the lamp is not lit Check that the lamp is securely placed in its holder by opening the cover Check that...

Отзывы:

Похожие инструкции для AirCare Series