2.  Item Check List

bx-ESG:

• 

1 x operating instructions

• 

1 x dehumidifying controller

• 

2 x temperature/dampness sensors

• 

2 x sensor cables 10 m

• 

4 x expansion anchors 6 mm (sensor)

• 

4 x assembly screws (sensor)

• 

4 x expansion anchors 6 mm (housings)

• 

4 x assembly screws (housings)

• 

1 x plug 

• 

optional: 1 x interior sensor

• 

optional: 1 x sensor cable 10 m

• 

optional: 1 x coupler module

3.  Technical Data

4

bx-ESG-UN:

• 

1 x operating instructions

• 

1 x dehumidifying controller

• 

2 x temperature/dampness sensors

• 

2 x sensor cables 10 m

• 

4 x expansion anchors 6 mm (sensor)

• 

4 x assembly screws (sensor)

• 

4 x expansion anchors 6 mm (housings)

• 

4 x assembly screws (housings)

• 

1 x power supply (in-wall)

• 

optional: 1 x interior sensor

• 

optional: 1 x sensor cable 10 mste

• 

optional: 1 x coupler module

Air Conditioning System bx-ESG

Electrical connection 

220 -240 ~ (power supply unit) 

Power consumption (ESG + mains adaptor) 

<10 W

External connection (floating contact)

Max. 1800 W

Protection class

Protection class 2

Frost protection (adjustable)

ON/OFF (standard ON)

Frost protection temperature (adjustable)

0 – 15 °C (standard 5 °C)

Active period (adjustable)

0 – 60 minutes (standard 10 minutes)

Inactive period (adjustable)

0 – 60 minutes (standard 10 minutes)

Switching difference (indoors/outdoors)

0.5 g/m³

Operation hours from (adjustable) 

0:00 - 23:30 hours

Operation hours to (adjustable)

0:00 - 23:30 hours

Minimum air humidity (adjustable)

0 – 100%

Maximum temperature (adjustable)

0 - 40°C

Temperature/Humidity Sensor bx-ESG-TF

Response time 

8 seconds

Energy consumption 

3.2µW (at 8 bit, 1 metering / s)

Measuring range: relative humidity

0 - 100%

Measuring range: temperature

- 40 to 125 °C

Humidity tolerance

2%

Temperature tolerance

0.3 °C

Dimensions (H x L x W)

40 x 64 x 24 mm

Distance between drilled holes

18 mm

Содержание bx-ESG

Страница 1: ...tion Control Unit Keep these installation instructions in safe place in the vicinity of the control unit When maintenance or repair work is required it is very important that these instructions are available with concealed power valve bx ESG UN bx ESG ...

Страница 2: ...3 Diagrams 6 3 4 Wiring for Power Supply in wall 7 4 INITIAL SETUP 8 4 1Assembly instructions 8 4 2 Assembly 8 5 OPPERATION MODE 9 5 1 Adjustable Values 9 6 KEYBOARD DISPLAY 9 6 1 Adjustmens 10 7 OPTIONAL ACCESSORIES 11 Notes Contact data 12 2 Warning Opening the internal equipment terminal box and the connection to electricity mains may only be done by an authorized electrical specialist ...

Страница 3: ...e bioxX dehumidifying controller bx ESG can be used in both home and the commercial sector Ensure that dampness due to defective construction parts gutters roofs etc is avoided this can be achieved by routine repairs The bx ESG can also be used for temperature control of cellars restaurants offices and dwellings minimum and maximum temperature Home Office Ventilating of rooms with high air humidit...

Страница 4: ...ditioning System bx ESG Electrical connection 220 240 power supply unit Power consumption ESG mains adaptor 10 W External connection floating contact Max 1800 W Protection class Protection class 2 Frost protection adjustable ON OFF standard ON Frost protection temperature adjustable 0 15 C standard 5 C Active period adjustable 0 60 minutes standard 10 minutes Inactive period adjustable 0 60 minute...

Страница 5: ...3 1 Dimensions Back View Drilling Measurements Right Side View Front View Dimensions Width x Height x Depth 155 x 160 x 50 mm 5 ...

Страница 6: ...Connections 3 3 Diagrams bx ESG bx ESG UN 6 Unterputznetzteil indoor sensor 1 indoor sensor 2 outdoor sensor Network Power 9V DC outdoor sensor indoor sensor outdoor sensor indoor sensor plug power supply in wall ...

Страница 7: ...3 4 Wiring for Power Supply in wall l Warning When connecting the Power Supply to the controller the polarity needs to be considered Red Cable Black Cable 7 ...

Страница 8: ...2 Assembly Mark the wall where holes should be drilled Drill and insert expansion anchors Turn provided screws into the two upper holes and let the screws stand out 3 mm Hang the controller on the screws Loosen the two lower screws on the housings which removes the lower cover to open the housing Turn the bottom two screws in to fix the housing to the wall Connect the potential free contact as a r...

Страница 9: ... Freeze Protection Temperature Switching Limit Inside outside Upper Temperature Threshold Temperature Control Forced Ventilation 6 Buttons Display Die keypad consists of Up down left and right arrow keys blue OK Button green Basic Settings Button red The 4 line LED display shows all necessary data In the operation status you can scroll through the different menu displays by pressing the right and ...

Страница 10: ...de outside relative humidity inside outside date time current date and time Settings for Humidity Control parameter adjustments frost protection ON OFF minimum temperature relative humidity minimum value absolute humidity difference inside to outside difference value to start the vantilation run pause time run time pause time ventilation active run time from run time to 10 Display Temperature Cont...

Страница 11: ...ories Additional indoor sensor Product No bx0520 Sensor cable Product No bx0522 Coupling module Product No bx0521 In order to extend the sensor wire by 10 m a coupling module for connection with the cable is necessary 11 ...

Страница 12: ...QR Code bx ESG bioxX systems GmbH CEO Karsten Butze Dresdner Str 172 01705 Freital Mobil 49 0 178 77 303 77 Tel 49 0 351 212 936 52 Fax 49 0 351 418 867 549 www bioxx system de info bioxx system de 12 V 2 8 1 ...

Отзывы: