operate. If the unit senses a person's movement during operation, the red indicator on the panel 

will change from steady light on to slow flashing, the unit stops running, and the STANDBY 

indicator turns on. To start again, press the TIMER key.

Boost is a more powerful mode for use only when no person(s) is present.

BOOST Mode

1. 

Press the TIMER key to start the unit, use the TIMER key to select the running time:

2 / 12 / or 24 hours continuous operation.

2. 

Press and hold the LEVEL button for at least 3 seconds to activate the Boost mode.

3. 

The device emits 3 beeps, the BOOST indicator will light up and start to run in the Boost mode.

※ You can press the LEVEL button again to return to the comfort mode.

The unit will configure the air volume according to the time setting first, 

and user can change it later.

6.HOW TO USE

Be sure to use the mode without anyone around.

FAN SPEED

After selecting the running time, the unit 

will automatically configure the air volume.

User can adjust it by FAN SPEED key. Check 

the table on the right for reference.

WATER

LOW 

ON

REFILL

TANK

REPLACE

FILTER 

REPLACE 

CELL

SERVICE

STANDBY

24 Hr

12 Hr

2 Hr

HIGH

MID

LOW

BOOST

COMFORT

REFILLING

SMART SENSOR

TIMER

FAN SPEED

LEVEL

HUMIDIFIER

GENERATOR

Be sure to confirm that there is no one in the room, and choose the operating time 

carefully to prevent someone from entering by mistake.

SMART SENSOR

LEVEL

FAN SPEED

Beep x3

TIMER

Beep

Press again TIMER 

button

Turn off the SMART SENSOR

Restart the system

4. 

If you choose the Boost mode, for safety reasons, the device will beep every 10 minutes.

This warning sound cannot be cancelled.

※ Switch the setting during system operation, the running time will be recalculated.

※ When the system is in standby (the ozone function is not running), the SMART SENSOR function sleeps.

※By default, the SMART SENSOR function in Comfort mode 
     is turned off and turned on in Boost mode.

5. 

The unit produces ozone in the first half of each cycle during operation, and air circulation in the second half.

 When the time expires, the ozone concentration will fall within the safety standard.

At the end of the operation time, the ozone concentration will drop to the safe allowable range, but if you feel a strong 

ozone smell when you enter the room, please open the window for ventilation.

m

Air Volume

(FAN SPEED)

150
100

50

ft

1600
1060

530

S

M

L

When you activate the Boost mode, please leave the room immediately.For safety reasons, the smart sensor will be 

triggered and stop the unit automatically if you enter the room. To restart, press the TIMER key.

Beep x3

LEVEL

3 sec.

Beep

Press and hold the FAN 

SPEED and LEVEL buttons 

for 3 sec.. The SMART 

SENSOR is turned off when 

you hear three beeps.The 

SMART SENSOR indicator 

goes out in the mean time.

11

2

2

Space  Area

*The max area of recommendation

Person(s) sensing function (SMART SENSOR) will be activated 5 minutes after the device starts to 

Содержание PROFESSIONAL EOS7190-P

Страница 1: ...es 5 Preparation Before Use 6 How to Use 7 Maintenance 8 Troubleshooting 9 Speci cations Warranty Description P2 P3 P5 P6 P7 P8 P8 P9 P10 P11 P12 P14 P15 P1 P16 Table of Contents Space Sanitizer Syste...

Страница 2: ...EOS7190 P V2 1 EN...

Страница 3: ...rying to repair or install 3 The labor costs derived from the normal maintenance calibration or general adjustment speci ed in this manual 4 Maintenance or damage caused by alteration abuse re ood or...

Страница 4: ...cause personal injury 2 or property damage 3 if not avoided CAUTION indicates a dangerous situation that may cause personal injury 2 or property damage 3 if not avoided Do not use this product in plac...

Страница 5: ...product The input power of the power adapter of this product is AC100 240V Do not use loose sockets Otherwise it may cause re electric shock or short circuit Do not use a damaged power cord or power...

Страница 6: ...e do not use electrical electronic contact cleaners in addition to damaging to the appearance these chemicals may also melt the parts Do not rinse the main device with water If the main unit is dirty...

Страница 7: ...REFILLING SMART SENSOR 12 9 11 10 1 3 4 5 6 7 2 8 FAN SPEED HUMIDIFIER GENERATOR TIMER LEVEL Mode Humidi cation Start Stop Timing Air Volume Water Replenishment Captions 4 1 Fault indicator 2 Standby...

Страница 8: ...g to the Food and Drug Administration FDA According the Occupational Safety and Health Administration OSHA the concentration standard for continuous exposure to ozone is limited to exposure for 8 hour...

Страница 9: ...sing please hang the product on the wall or place it on a rm and at table or shelf When ozone is generated the blue operation indicator on the top of the unit will be lit This light cannot be turned o...

Страница 10: ...Water shut o valve Plug 6 Press the GENERATOR button to start the water pump The device will beep to start replenishing pure water At this time the REFILLING indicator will light up 7 After the water...

Страница 11: ...he STANDBY indicator lights up and the device stops working Stop Operation After pressing the TIMER button to start running the system will rst run with the default value of low air volume for 2 hours...

Страница 12: ...tering by mistake SMART SENSOR LEVEL FAN SPEED Beep x3 TIMER Beep Press again TIMER button Turn o the SMART SENSOR Restart the system 4 If you choose the Boost mode for safety reasons the device will...

Страница 13: ...LACE FILTER indicator lights up stop the operation and replace the DI water lter and HEPA lter at the same time Click It must be replaced regularly to maintain the performance of the equipment When th...

Страница 14: ...idifying water will be drained immediately after removing the silicone cover Discharge the humidi cation water and the pure water of the EOG Drain humidi cation water Drain pure water 2 3 1 Inside of...

Страница 15: ...down the two tabs at the bottom and then remove the bottom cover 2 Separate the terminals of EOG and the main unit 5 Connect the terminals Inside the bottom cover Connection terminal Mark EOG 3 Rotat...

Страница 16: ...ons in Section 5 5 If the indicator warning still cannot be removed please contact your service agent Insu cient pure water for the EOG The REFILL TANK indicator lights up The system can work normally...

Страница 17: ...ns for use care or maintenance Removal alteration or defacing of the BES a xed serial number and other labels Mechanical damage Use of uids other than clean potable water This warranty is conditional...

Страница 18: ...Memo...

Страница 19: ......

Страница 20: ...www besgroups com info besgroups com BES Group Biotek Environmental Science Ltd...

Отзывы: