background image

 

 

Содержание FTA-1

Страница 1: ......

Страница 2: ...oducts or services we would like to hear from you Please send all feedback to Manufacturer SIA Biosan Ratsupites 7 k 2 Riga LV 1067 Latvia Phone 371 674 261 37 Fax 371 674 281 01 https biosan lv Marke...

Страница 3: ...12 8 Chemical compatibility 13 9 Care and maintenance 16 10 Storage and transportation 17 11 Warranty 18 12 EU Declaration of conformity 19 1 About this edition of user instructions 1 1 The current ed...

Страница 4: ...port the unit as described in section 10 Storage and transportation on page 17 Use only original parts and accessories provided by manufacturer for this product Before using any cleaning or decontamin...

Страница 5: ...use outside laboratory rooms Do not use the unit for aggressive organic compounds chlorinated solvents and strong conjugated acids see section 8 Chemical compatibility on page 14 2 5 Biological safet...

Страница 6: ...h single 200 and 1000 L tip using the MA U adapter or with the handheld vacuum controller HAS 1 with different attachments such as 8 channel adapter with stainless steel tips 8 channel adapter for 200...

Страница 7: ...pcs Spare hydrophobic filter 1 pce External power supply 1 pce Operating instructions certificate 1 copy MA 8 8 channel aspiration tip with holder on request 4 2 2 FTA 2i FTA 2i aspirator with flask t...

Страница 8: ...e tubing Caution Position the filter with the IN marking pointing towards the unit fig 1 2 Screw on the lid with the filter set and aspiration tubing to trap flask Ensure that the filter set is tightl...

Страница 9: ...ite ring on the lid Ensure that the filter set is tightly fixed in the slot fig 7 1 Assemble the MA U aspiration tip set figure 5 Attach the fitting fig 4 3 of the tubing for liquids fig 4 4 and 5 3 t...

Страница 10: ...ccording to 5 6 Note In model FTA 2i when collected liquid exceeds the maximum level the sensor turns off the pump and produces sound and light warning sig nals 5 4 1 For model FTA 2i When using the o...

Страница 11: ...itional notice Model FTA 1 FTA 2i Aspiration speed up to 1 7 mL s up to 27 8 mL s Vacuum regulation Yes Working vacuum pressure at sea level 500 mbar 200 800 mbar Overflow protection sensor Yes invasi...

Страница 12: ...pin fig 8 9 1 channel adapter with ejector for 200 L tips fig 8 10C Stand SH 6 for hand operator parts fig 8 10 BS 040118 PK Extended tubing 2 m with fittings and MA U adapter BS 040120 DK 7 2 2 Repla...

Страница 13: ...Edition 1 4 03 13 1 2 3 4 5 6 7 8 9 10 Figure 8 Optional accessories and replacement parts...

Страница 14: ...is correct or com prehensive and that any material is fit for any purpose 8 2 Resistance grades used in tables 1 Excellent at ambient temperature and pressure the material should not be affected 2 Go...

Страница 15: ...CO Tubing Silicone 2 2 3 3 1 3 Bottle 2L Polypropylene 1 1 1 1 1 1 Lid Polypropylene 1 1 1 1 1 1 Lid seal TPE 1 3 1 1 1 1 Level detection pins Stainless steel 3 3 3 2 1 1 Fittings Polypropylene 1 1 1...

Страница 16: ...no less than 0 5 L and air dry after rinsing 9 2 4 Autoclaving procedures Lid fittings tubing Flask Hydrophobic filter cables base pump FTA 1 121 C and 1 atm 15 min 121 C and 1 atm 55 min Do not autoc...

Страница 17: ...not use the unit with a foaming liquid or use antifoaming agent 9 6 Disposal Disposal of the appliance requires special precautions and must be carried out at an appropriate disposal site separate fr...

Страница 18: ...istration during 6 months from the date of sale Online regis tration form can be found in section Warranty registration on our website at the link below For FTA 1 the Basic Plus class model extended w...

Страница 19: ...ements EMC 2014 30 EU LVS EN 61326 1 2013 Electrical equipment for measurement control and laboratory use EMC requirements General requirements RoHS3 2015 863 EU Directive on the restriction of the us...

Страница 20: ...SIA Biosan Ratsupites 7 k 2 Riga LV 1067 Latvia Phone 371 67426137 Fax 371 67428101 https biosan lv Edition 1 4 03 July of 2022...