Страница 1: ......
Страница 2: ...services we would like to hear from you Please send all feedback to Manufacturer SIA Biosan Ratsupites iela 7 k 2 Riga LV 1067 Latvia Phone 371 674 261 37 Fax 371 674 281 01 www biosan lv Marketing m...
Страница 3: ...recautions Caution Make sure you have fully read and understood present instructions before using the equipment Please pay special attention to sections marked by this symbol Caution The front protect...
Страница 4: ...label Do not plug the unit into an ungrounded power socket and do not use an ungrounded extension lead Ensure that the power plug is easily accessible during use Disconnect the unit from the mains bef...
Страница 5: ...ed to UV radiation It allows continuous treatment of the airflow with UV light without interrupting working process Air circulation at a short distance from the UV lamp combined with reflective surfac...
Страница 6: ...w the instructions included on the pack aging 4 2 Complete set Package contents 4 2 1 Standard set DNA RNA UV cleaner box 1 pce Power cable UVC T AR only 1 pce Spare fuse for control block1 1 pce Spar...
Страница 7: ...cable fig 5 1 is connecting the fuse box and the controller top 5 1 Connect the power plug to a grounded power socket Turn on the Power switch UVC T AR no switch the unit powers up automatically UVC T...
Страница 8: ...e unit 5 2 5 If the set time of open UV light exposition is 0 00 pressing the Start key will make the unit operate continuously during 24 hrs or until the Stop Reset key is pressed 5 3 The box is read...
Страница 9: ...ent and reserves the right to alter design and specifications of the equipment without additional notice Model UVC T AR Compact UVC T M AR Compact UVT B AR Compact UVT S AR Double Back panel PMMA Stee...
Страница 10: ...Dimensions 720x535x555 mm 700x580x555 mm 1250 x 600 x 590 mm Weight net gross 2 23 33 kg 28 8 39 kg 31 2 42 kg 58 68 5 kg Laboratory table T 4 T 4L 6 1 Used materials PMMA polymethylmethacrylate acryl...
Страница 11: ...AB V 5A7 1 3 x US type B BS 040107 AA7 V 5A04 1 3 x AU type I BS 040107 A04 V 5AI 1 3 x IL type H BS 040107 AIL Caution Overall consumed power of devices connected through internal mains sockets shoul...
Страница 12: ...y pulling out the holder fig 4 compact models or by screwing off the holder lid marked FU2 fig 6 model UVT S AR Check the fuse and replace if necessary 3 15 A type M time lag Medium 8 2 2 Fuse for the...
Страница 13: ...ing cleaners more than 20 or ammonia containing cleaners for acrylic glass Do not use abrasives The table below shows the interaction of acrylic glass with ethyl alcohol and other solutions Solution I...
Страница 14: ...ocal distributor address To obtain the claim form visit Technical support page on our website at link below 10 5 Extended warranty For UVC T M AR UVT S AR the Premium class model one year of extended...
Страница 15: ...ts for electrical equipment for measurement control and laboratory use General requirements EMC 2014 30 EU LVS EN 61326 1 2013 Electrical equipment for measurement control and laboratory use EMC requi...
Страница 16: ...Biosan SIA Ratsupites 7 k 2 Riga LV 1067 Latvia Phone 371 67426137 Fax 371 67428101 http www biosan lv Edition 3 6 02 March of 2021...