12. Care And Cleaning

Use an alcohol swab or cotton tissue moistened with alcohol (70% Isopropyl) 
to clean and disinfect the thermometer casing and the measuring probe. 
Ensure that no liquid enters the interior of the thermometer. Never use abrasive 
cleaning agents, thinners or benzene for cleaning and never immerse the 
instrument in water or other cleaning liquids. Take care not to scratch the 
surface of the probe lens and the display.

It is important to clean the thermometer before and after each use. A build up 
of ear wax on the lens reduces the infrared picked up by the sensor, which can 
result in lower temperatures. Ear wax is also acidic and can corrode the lens of 
the thermometer if not cleaned regularly.

13. Battery Replacement

This thermometer is supplied with one lithium battery type, CR2032.

1.  The battery needs replacing when only the   icon is shown 

on the display. 

(Figure 7)

2.  Loosen the screw with a screwdriver, and lift the screw up 

manually, then remove the battery cover by sliding in the 
direction shown. Remove the battery and replace with a new 
one.

Note: Battery cover should be installed correctly before use to avoid 
potential risk of electric shock

Figure 7

Содержание Diagnostics halo 235DI

Страница 1: ...1 SECOND EAR THERMOMETER Instruction Manual Model 235DI 1 18 2021...

Страница 2: ...4 How this Thermometer Measures Temperature 5 Setting Date and Time 6 Directions for Use 7 Setting the Beeper 8 Fever Alarm 9 Changing Between Celsius and Fahrenheit 10 Memory Storage 11 Measuring Su...

Страница 3: ...bath Ambient temperature Measurement in 1 Second The innovative infrared technology allows measurement of ear temperature in only 1 second Multiple Reading Recall Users will be able to recall the last...

Страница 4: ...quality precision parts Do not drop this instrument Protect it from severe impact and shock Keep the thermometer away from direct exposure to the sun and keep it in a dust free dry area If the instru...

Страница 5: ...e Measurements taken from the surrounding tissue of the ear canal generate lower readings and may result in misdiagnosis of fever 5 Setting Date And Time 1 When using the Ear Thermometer for the first...

Страница 6: ...rmometer on by pressing the button all segments of the screen will be shown for 1 second and one beep is heard Figure 1 1 When the thermometer is ready to take a reading the C or F icon will be flashi...

Страница 7: ...mory icon M will flash Figure 4 Reading 1 the last reading Press and release the M button to recall the last reading Number 1 and a flashing M are displayed Figure 5 The last reading displays the date...

Страница 8: ...fter each use A build up of ear wax on the lens reduces the infrared picked up by the sensor which can result in lower temperatures Ear wax is also acidic and can corrode the lens of the thermometer i...

Страница 9: ...40 0 C 104 0 F Ambient temperature too low Displays L when ambient temperature is lower than 10 0 C 50 0 F Error function display The system has a malfunction Blank display Check if the battery has be...

Страница 10: ...he display light will be GREEN for 5 seconds when a measurement is completed with a reading less than 37 5 C 99 5 F The display light will be RED for 5 seconds when a measurement is completed with a r...

Страница 11: ...Guarantee If at any time you are not completely satisfied with the performance of this device call our BIOS Medical Hotline and speak with a customer service representative who will make arrangements...

Страница 12: ......

Отзывы: