background image

i)  Consecutive measurements will cause blood 

accumulation in the lower arm which will affect the 

measuring results. To improve reading accuracy, raise 

the arm being measured, squeeze and relax your hand 

several times, then take another measurement. Another 

option is to take the cuff off and wait at least 5 minutes 

before repeating measurement.

j)  If this device was stored in low temperature, it is necessary to leave it in room temperature for at 

least 1 hour, otherwise the measurement can be inaccurate.

Comment:

Continue to use the same arm for comparisons.  It is not unusual for there to be a difference in blood 

pressure between arms.
Comparable blood pressure measurements always require the same conditions (Relax for several minutes 

before taking a measurement).

ATTENTION: Do not use a cuff other than the original cuff contained in this kit!

3.4 Measuring Your Blood Pressure

After following the guidelines described in the previous section and placing the cuff around your upper 

arm, you are now ready to measure your blood pressure. Follow these steps to record your measurement.
1.  Press the   button to turn on the device and start measurement. The LCD screen is turned on. The 

cuff begins to inflate while the increasing cuff pressure is displayed on the screen. After the suitable 

inflation pressure is reached, the cuff stops inflating and the pressure gradually falls. A long beep 

sounds when the measurement is completed. The systolic and diastolic blood pressure values along 

with the pulse rate are displayed on the screen. The measurement is displayed for approximately 1 

minute.

2.  Switch off the device by pressing the   button to preserve the batteries. If no button is pressed for 1 

minute, the instrument switches the display off.

NOTE:

 The time will continuously be displayed on the screen.

3.5 Appearance of the Atrial Fibrillation Indicator (only in MAM mode)

This symbol 

 indicates that atrial fibrillation was detected during the measurement. If AFIB is 

present during blood pressure measurement, the AFIB Indicator is displayed. The AFIB 

 will flash 

8 times rapidly once the measurement is complete and then stop flashing. In this case, the result may 

deviate from your normal blood pressure. It is highly recommended to take an additional measurement 

an hour later to increase the specificity of the detection. In most cases, this is no cause for concern. 

However, if the symbol appears on a regular basis (e.g. several times a week with measurements taken 

daily) we advise you to visit your doctor. Please, provide the following explanation:

i)

Содержание ULTRA BD350

Страница 1: ...od Pressure Monitor ULTRA With Atrial Fibrillation Screening Instruction Manual Model BD350 www biosmedical com Go to biosmedical com for a FREE Guide Book on Measuring Blood Pressure at Home 03 20 20...

Страница 2: ...ut we know that millions of our home use monitors have been used by Canadians in the last 30 years All BIOS Diagnostics devices are developed in collaboration with physicians and clinically tested to...

Страница 3: ...rillation AFIB 1 7A What is Atrial Fibrillation 1 7B How Does AFIB Impact my Family or Me 1 7C AFIB Detection Provides a Convenient Way to Screen for AFIB only in MAM Mode 1 7D Risk Factors you Can Co...

Страница 4: ...4 Software Functions 5 Error Messages Malfunctions 6 Care and Maintenance 7 Lifetime Guarantee 8 Technical Specifications...

Страница 5: ...nce any symptoms Appropriate treatment can reduce your risk of suffering a stroke For this reason it is recommended that you visit your doctor when the device gives an AFIB signal during your blood pr...

Страница 6: ...home as well as at your doctor s clinic Try to record your blood pressure regularly at the same time of the day and under the same conditions This will help your physician detect any extreme variation...

Страница 7: ...humidity or in places with a lot of dust Clean the device with a soft dry cloth Do not use gasoline thinner or similar solvents Carefully remove spots on the cuff with a damp cloth and soap Do not was...

Страница 8: ...an error code the product is working properly In extremely rare cases the cuff may have developed a pin hole leak or the gasket where the cuff connector enters the monitor may not have a proper seal...

Страница 9: ...sion 140 159 90 99 This is in the hypertension range Discuss with your health care professional Medication s and lifestyle modifications are typical treatments 160 and higher 100 Discuss with your med...

Страница 10: ...or blood pressure to increase due to anxiety and tension this is known as White Coat Hypertension c Why should I monitor blood pressure at home One or two readings will not provide a true indication o...

Страница 11: ...ells in your heart produce electrical signals that cause the heart to contract and pump blood Atrial fibrillation occurs when rapid disorganized electrical signals are present in the heart s two upper...

Страница 12: ...factors for strokes Knowing your blood pressure and knowing whether or not you have AFIB is the first step in proactive stroke prevention 2 Getting Started 2 1 About the BD350 a This section describe...

Страница 13: ...ry Low Battery 2 3 Inserting the Batteries Follow these steps to insert the four AA batteries in the device 1 Open the battery compartment cover in the direction shown 2 Insert the four AA batteries w...

Страница 14: ...t all the display elements When functioning correctly all segments must appear 3 Using the Device This section describes how to get the maximum benefit from your BD350 blood pressure monitor Follow th...

Страница 15: ...single average measurement A symbol in the display indicates that the unit is set to the Average Mode c There will be 15 seconds resting time in between each measurement The unit will count down from...

Страница 16: ...nt arm during the measurement Use a cushion for support if necessary ATTENTION Comparable blood pressure measurements always require the same conditions with a peaceful and calm environment Ensure tha...

Страница 17: ...f should fit snugly around your bare arm but not too tight You should be able to fit two fingers under the cuff If the cuff is the wrong size the deivce will not measure your blood pressure accurately...

Страница 18: ...on The cuff begins to inflate while the increasing cuff pressure is displayed on the screen After the suitable inflation pressure is reached the cuff stops inflating and the pressure gradually falls...

Страница 19: ...ously Recorded Values The blood pressure monitor automatically stores your measurements It can store up to 200 measurements When more than 200 measurements are made the oldest readings are deleted to...

Страница 20: ...last for 3 seconds The bars will then flash to indicate that the connection between computer and device is successfully made As long as the cable is plugged in the bars will keep flashing and the but...

Страница 21: ...ones The pressure does not rise even though the pump is running Check the connection of the cuff tube and connect properly if necessary The device frequently fails to measure the blood pressure values...

Страница 22: ...his invalidates the manufacturer s warranty g Batteries and electronic instruments must be disposed of in accordance with the locally applicable regulations not with domestic waste 7 Lifetime Warranty...

Страница 23: ...C 50 to 104 F Storage temperature 20 to 55 C 4 to 131 F 15 to 90 relative maximum humidity Weight 560 g including batteries Dimensions 152 x 92 x 42 mm Measuring procedure oscillometric corresponding...

Страница 24: ...ion Please read this document thoriughly before using the device and keep for future reference Type BF applied part Batteries and electronic devices must be disposed of in accordance with the locally...

Отзывы: