BIOS Diagnostics PROTOCOL 7D MII BD250 Скачать руководство пользователя страница 9

2.2 About the LCD Screen

The LCD screen displays the systolic and diastolic blood pressure measurements along with your heart rate. It 

also displays previously recorded measurements and the date and time, when the appropriate button is pressed.

2.3 Inserting the Batteries

Follow these steps to insert four “AAA” batteries into  

the device.

1. Open the battery compartment cover on top of the monitor.

2. Insert  four “AAA” batteries with the correct polarity  

as indicated.

3. Replace the battery compartment cover.

Attention! 

•  After the battery warning appears, the device is blocked until the batteries have 

     been replaced. 

•  Please use “AAA” Long-Life or Alkaline 1.5V batteries.  

•  If the blood pressure monitor is left unused for long periods, please remove the batteries     

     from the device. 

•  Do not mix old and new batteries. Do not mix alkaline, standard (carbon-zinc) or  

     rechargeable batteries.

Year/Month/Date/Time

Systolic blood pressure

Diastolic blood pressure

Pulse rate

Heartbeat rhythm
Irregular heartbeat

User

Bluetooth On

Blood Pressure 

Classification

Memory symbol

Memory times

Low battery

+

-

Содержание PROTOCOL 7D MII BD250

Страница 1: ......

Страница 2: ...Canada We haven t been counting but we know that millions of our home use monitors have been used by Canadians in the last 30 years All BIOS DiagnosticsTM devices are developed in collaboration with...

Страница 3: ...g Time Date and Year 3 3 Obtaining Accurate Measurements 3 3A Before Measuring 3 3B Common Sources of Error 3 3C Fitting the Wide Range Cuff 3 4 Protocol Software 7D Mode 3 5 General Mode 3 6 Measurin...

Страница 4: ...ers 90 blood pressure readings each with time and date Free BP Toolbox APP This monitor will connect via Bluetooth to Android and iOS devices The BP Toolbox APP enables users to send secure data to ph...

Страница 5: ...a few minutes before you record your blood pressure Your blood pressure increases or decreases under the following circumstances Blood pressure is higher than normal When you are excited nervous or t...

Страница 6: ...ong and medium term health risks These risks concern the arterial blood vessels of your body which are endangered due to constriction caused by deposits in the vessel walls arteriosclerosis A deficien...

Страница 7: ...hysician For further information see our website www biosmedical com If your values are mostly normal under resting conditions but exceptionally high under conditions of physical or psychological stre...

Страница 8: ...ture nervous condition When measuring blood pressure at the doctor s office it is possible for blood pressure to increase due to anxiety and tension c Why should I monitor blood pressure at home One o...

Страница 9: ...ect polarity as indicated 3 Replace the battery compartment cover Attention After the battery warning appears the device is blocked until the batteries have been replaced Please use AAA Long Life or A...

Страница 10: ...store in the memory 2 Repeat the same process to set the MONTH by pressing the MEM button Press the SET button to store it in the memory 3 The same process is repeated to set the DATE The date will f...

Страница 11: ...elaxed position and do not activate any of the muscles in the measurement arm during the measurement Use a cushion for support if necessary ATTENTION Comparable and reliable blood pressure measurement...

Страница 12: ...ve measurements will cause blood accumulation in the lower arm which will affect the measuring results To improve reading accuracy raise the arm being measured squeeze and relax your hand several time...

Страница 13: ...our arm supported and legs uncrossed Avoid all movement and muscle tension Breathe normally and do not speak Wait at least 1 minute between consecutive measurements AM PM measurements should be taken...

Страница 14: ...n be displayed In case the initial inflation is not sufficient the device automatically re inflates to a high pressure 3 When the device detects a heartbeat the heart symbol on the display starts to f...

Страница 15: ...al com or call our BIOS Medical Hotline 1 866 536 2289 3 9 Memory Recall This blood pressure monitor automatically stores 90 measurements for each user in its memory The 90 memories are split between...

Страница 16: ...EM button the symbols and will appear on the screen This means that the memory has successfully cleared 3 11 Blood Pressure Assessment Indicator The bars on the left hand side of the display show you...

Страница 17: ...magnetic interferance can cause odd behaviour in the monitor Move away from the source Appears when there is an error during the inflation process Make sure the cuff is wraped around the arm properly...

Страница 18: ...tenance a Do not expose the device to either extreme temperatures humidity dust or direct sunlight b The cuff contains a sensitive air tight bubble Handle this carefully and avoid all types of stress...

Страница 19: ...return the unit with all component pieces Enclose proof of purchase and 5 00 for return shipping and insurance Ship the unit prepaid and insured at owners option to Email support biosmedical com Plea...

Страница 20: ...l carefully before using this device especially the safety instructions and keep the instruction manual for future use Type BF applied part Batteries and electronic devices must be disposed of in acco...

Отзывы: