DVM06U3

eSATA+USB2.0

model

取扱説明書

 

 

  0 

 

Best 

Energy

  and Space Saving RAID 6 

Portable 2.5

”HDD

×

6

Desktop Model 

 

---------------------------------------------------------------------------- 

 

DVM06U3 

 

 

  USB3.1 Gen2   

 

 

  User Manual 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Revision 1.0 

 

 

----------------------------------------------------------------------------

 

 

Содержание DVM06U3

Страница 1: ...DVM06U3 eSATA USB2 0 model 0 Best and Space Saving RAID 6 Portable 2 5 HDD 6 Desktop Model DVM06U3 USB3 1 Gen2 User Manual Revision 1 0...

Страница 2: ...following provide examples of the warning drawings This symbol means that you should pay extra attention This symbol indicates something you absolutely must not do This symbol indicates necessary act...

Страница 3: ...re the properties of their respective owners If you purchased a DVM06U3 storage system without preinstalled disk drives you must add disk drives into your storage before you use it Default pre install...

Страница 4: ...lever HDD Installation Install and Remove HDD Module Before you start any operation please make sure HDDs are installed properly into the DVM06U3 enclosure An alarming beep sound will be turned on an...

Страница 5: ...oving power cable There is a risk of electrocution Don t pull on the cable itself There is a chance of fire Never operate unless the power plug is fully inserted It may short out and generate excessiv...

Страница 6: ...of the product You cannot change the order of the drives once the RAID mode has been established Please use the six drives in the order that they were installed at time of RAID creation Please be sure...

Страница 7: ...places It may fall and break and may cause injury Never use with more than the rated voltage There is a risk of electrocution Don t use the cable in anything but the approved power terminal There is...

Страница 8: ...D module unlock There is risk that HDD module falls out of the enclosure Never place the unit in any bags or containers containing liquids There is a risk of fire inside the unite or electrocution Kee...

Страница 9: ...8...

Страница 10: ...n 28 2 5 3 Quick Overview of From Panel Button Operation 29 2 6 Web based Monitor and Setup via Ethernet 30 2 6 1 Main Screen of Web GUI 30 2 6 2 Introduction of Monitor Mode 31 2 6 3 Management Mode...

Страница 11: ...10 4 6 1 Transfer Rate Display 72 4 6 2 Cache Check Display 72 4 6 3 Most Delay CH Display 72 4 6 4 LCD Display for Patrol Mode Options 73 4 7 Retry Error Detection Drive SENSE DATA Display 74...

Страница 12: ...ess integrated RAID system Support six hot swappable 2 5 SATA drive canisters with Lock Support RAID 6 RAID 0 RAID 3 RAID 5 RAID 10 USB3 1 10Gbits sec Theoretical value backward compatible with USB3 0...

Страница 13: ...me setup Error message emailing SMTP support SNMP Trap Support Auxiliary Function Data Transfer Speed Display on LCD Each drive and host channel speed Event Display on LCD Buzzer Alarm Fault LED Indic...

Страница 14: ...t bottom drive is reserved for future usage Data and Parity are distributed among 5 HDDs Since there is no assigned disk for parity each drive shares the same loading in data access Data Drive All dri...

Страница 15: ...formance and security can be raised Stripe across mirrored Drive 0 1 and Drive 2 3 Capacity is equal to 2 drives capacity Data can be accessed even one of both mirrored pair drives failed The rest of...

Страница 16: ...s opened If you found missing items please contact your reseller And please keep the original packing carton and materials USB cable might be different depending upon the request DVM06U3 Accessories D...

Страница 17: ...16 1 5 Name and Function of each part Front side Rear Side...

Страница 18: ...see the status of module LCD Display of DVM06U3 status or parameter POWER LED Blue when system is turned on ACCESS LED Green flash when host is accessing the storage system FAIL LED Orange ON when a p...

Страница 19: ...teps Tips Below steps is applied to the storage unit pre configured with drives and RAID level upon procurement If the unit was procured without drives please read the quick installation guide before...

Страница 20: ...dule Send back Extension Service Pack Part Number Description DVM06U3 SEDBK 1Y Extra one year send back service Total 3 years DVM06U3 SEDBK 2Y Extra two year send back service Total 4 years DVM06U3 SE...

Страница 21: ...20...

Страница 22: ...red Any error identified or status changed will be dynamically reflected to its respective indicators such as LED light buzzer alarm and LCD display etc Only if you wanted to change parameter setting...

Страница 23: ...meters Setting mode MODE Button SELECT Button Power On Rotate among Setup items MODE Button Setup parameters SELECT Button Following selection of parameters press both MODE and SELECT button at the sa...

Страница 24: ...ARRAY PARAMETERS SETTING Initial Display Disk Size Setup Hard Disk Capacity Setup RAID MODE Setup RAID Mode Setup DRIVE MODE Setup Number of Drive Setup RECOVERY MODE Setup Priority of RAID Rebuild S...

Страница 25: ...than supported listing will be added in future upon firmware upgrade Please check our website for new firmware Tip Always set the size equal to claimed size of the drive Parameter Function Memo Test 1...

Страница 26: ...t data access without interrupting the current host application Therefore data read write priority can be adjusted through different recovery rate setting User can choose the timing to execute recover...

Страница 27: ...ule patrol all disk in 30 days cycle Default System Patrol 5 10 20 Days Cycle Calculate of the whole LUN size and schedule patrol all disk in 5 10 20 days cycle System Patrol Wait 10S 5S 3S System Pat...

Страница 28: ...e faster the number is increased Push the MODE button to move to next field Again Management GUI is recommended Address Mask Setup Address Mask 255 255 255 0 This is to setup IP address mask same as I...

Страница 29: ...er Default or Pre set Notes Firmware Firm ware is Ver x xxx Information only for reference Vendor ID Vender ID is BIOS Information only for reference Model No Product ID is DVM06U3 Information only fo...

Страница 30: ...uring operation escape Cancel RETRY display During operation press twice Performance information Under Browsing Parameters press Use to check each drive Cache Memory Confirmation Press after Performan...

Страница 31: ...rowser with IP address of the device http IP Address The Web GUI will be displayed as below for Monitor Mode The left hand side lists main menu items and the right side displays detail items or inform...

Страница 32: ...re status The refreshing interval can be changed by specifying the requested time and apply Change Refresh Interval Drive status is differentiated by color Green Red Yellow White Normal One Down Two D...

Страница 33: ...on main menu Basic Parameters to show basic RAID parameters Basic parameter screen shot Additional Parameters Click on main menu Additional Parameters to show additional RAID parameters Additional RA...

Страница 34: ...etwork related parameters Network related parameters screen shot Logged Data Click on main menu Logged Data to show Log data of the storage Logged data screen Log data shows the historic events after...

Страница 35: ...nly for firmware identification It varies from each firmware version The number 0020 0022 has special meaning for email notification error See Setup of email notification section below for explanation...

Страница 36: ...ick Login for Management Mode on main menu Pop window for User Name Password to enter Management mode Default password is passwd and user name is empty To change password refer to 2 7 Setup Change Pas...

Страница 37: ...After clicking To Management Menu extra menu Mail Setup and SNMP Setup will be shown on Main menu as below screen capture shown Users can configure EMAIL notification and SNMP setting so as Additiona...

Страница 38: ...llowed For users who want to have more than 2 receivers you need to setup aliases on assigned email server Allowable characters are same as Sender address SMTP Server Address 255 255 255 255 Setup IP...

Страница 39: ...failed after retried an error log will be recorded 0020 SMTP was not found 0021 Gateway was not found 0022 SMTP did not respond It might take up to 10 minutes for the retrial if the mail could not be...

Страница 40: ...ll be sent again upon the power recycling If there are more than two events happened at the same time only the first one will be sent 2 6 6 SNMP Setup Click SNMP Setup on Main Menu and follow below st...

Страница 41: ...Parameters In Management Mode you can click Additional Parameters on main menu to make the change of those parameters Additional Parameters Page Parameter settings under additional parameters can be c...

Страница 42: ...41 Scroll to the parameter value you wish to change then click Change Parameters button to save the change New parameters are effective at the time right after saving...

Страница 43: ...of parameters of the storage unit Power on the storage while holding both MODE and SELECT buttons about 3 seconds to Setup Mode LCD Display ARRAY PARAMETERS SETTING Launch the web browser with preset...

Страница 44: ...mple LUN Size Scroll to the parameter needed to be changed and click Change Parameters button to save it Reboot the RAID system to make new parameters effective Press MODE button at first time power o...

Страница 45: ...Basic Parameters Click Basic Parameters on main menu to enter Basic Parameters page Basic Parameters Page Only Read Ahead cache size is the only basic parameter Default size is 64KB Please refer to S...

Страница 46: ...utton to save it Then reboot the RAID system to reflect the change Please refer to Chapter 2 for details of Mail SNMP and Log menu explanation Firmware Update Click on Update Firmware on main menu to...

Страница 47: ...splay Please Wait Firm Updating Firmware is being updated Do not turn off power during firmware updating An uninterruptable power supply connection is recommended if the power source is not stable Pow...

Страница 48: ...is point Instead retry again without rebooting the system If the process still failed please contact our support staff Change Password In Setup Mode click Change Password on main menu to enter Change...

Страница 49: ...for each Mode with WEB GUI Menu Monitor Mode Management Mode Setup Mode Read Modify Read Modify Read Modify RAID Monitor O X O X X X Basic Parameters O X O X O O Additional Parameters O X O O O O Crit...

Страница 50: ...49 2 8 Host LAN Configuration 2 8 1 IP Setup for Windows 1 Go to Start Control Panel 2 Navigate to Network and Internet Network and Sharing Center...

Страница 51: ...rties First check use the following IO address Considering RAID IP ADDRESS is 192 168 50 210 set as follows IP address 192 168 50 XXX put unused address in place of XXX Subnet mask 255 255 255 0 Then...

Страница 52: ...enew Enter ipconfig all Check if the IP Address has been changed correctly 2 8 2 IP Setup for Linux 1 Open a Terminal Window 2 Enter ifconfig eth0 192 168 50 X Put IP that is not used in the current n...

Страница 53: ...52 2 8 3 IP Setup for MAC OS X Click System Preferences Click Network Icon...

Страница 54: ...53 Choose Configure option to Manually Enter IP address and click Apply button to save it Make sure the address used here is not used by another device...

Страница 55: ...54...

Страница 56: ...XX XX XX XX XX root Host name root 2 Partition Creation and formatting fdisk command start fdisk Example below is when DVM06U3 is recognized as dev sdb root sheep root fdisk dev sdb Creating partition...

Страница 57: ...or EXT2 FS 0 5b 95 08 09 Filesystem label OS type Linux Block size 4096 log 2 Fragment size 4096 log 2 183140352 inodes 366279984 blocks 18313999 blocks 5 00 reserved for the super user First data blo...

Страница 58: ...DVM06U3 then starts with host computer Press the Start Button and right click on Computer Click on Manage Go to Device Manager Click on Disk Drives and confirm that the DVM06U3 has been registered If...

Страница 59: ...n and Formatting Log into Windows 7 and click the Start then right click on Computer and click on Manage Click on Computer Management Storage Disk Management Right click Not initialize disk DISK1 then...

Страница 60: ...o be initialized and move on to the formatting If DVM06U3 has capacity over 2TB in Volume then choose GPT Disk label here to able to use disk over 2TB Right click on the disk you wish to edit and clic...

Страница 61: ...60 The New Volume Wizard will load up so click Next Choose the volume you want then click Next...

Страница 62: ...61 8 Choose the driver letter you wish click Next 9 Choose the proper formatting settings and click Next again...

Страница 63: ...ified that the settings are correct and there are no errors click Finish 11 The format will begin Close the Computer Management after the format has completed You can use the disk now please remember...

Страница 64: ...OS X user guide for details 1 Confirm the connection Connect USB cable between the device and Mac computer Power on DVM06 first and then power on Mac computer If connection is fine the disk detection...

Страница 65: ...64 3 Choose the disk to initialize eg 16 TB BIOS and click on Partition tab Click Partition Layout to set number of partitions you want 4 Input Partition Information as needed...

Страница 66: ...65 5 Apply partition and confirm Partition 6 Choose between Backup disk or not Upon completion of partition the disk can be used to back up with Time Machine or decide later...

Страница 67: ...66 7 Partition Completion...

Страница 68: ...ain system power on and contact your support window There might be possibility that data will be corrupted Shutdown both computer and DVM06U3 Press and hold the MODE button then turn on DVM06U3 power...

Страница 69: ...Y or blank character shown following the on LCD it might mean the drive connection is problematic In such case turn off the power and do not insert two failed drives Start with step 6 again When LCD s...

Страница 70: ...ecovery there should be character R X Y or blank character shown following the on LCD it might mean the drive connection is problematic In such case turn off the power and remove the failed drive star...

Страница 71: ...ve Press MODE button to stop buzzer alarm RAID x TWO DRIVE DOWN This means host access is still working under 2 failed drives status This will only be seen in RAID 6 mode Please check disk FAIL LED to...

Страница 72: ...overy process has been started FAIL LED of associated drive will keep light on till the completion of recovery operation 4 5 LCD Display for FAN Failure FAN STOP NORMAL When FAN is failed system FAIL...

Страница 73: ...ity LED worked normally or if HDD hang up is suspected RATE display will be exited if SCSI reset command was received Or you can press MODE and SELECT button at the same time to return to earlier stat...

Страница 74: ...EAD operation will be applied to all drives and if any error sector was found they will be automatically recovered Even when the host access is continuous a read will be attempted on all drives once e...

Страница 75: ...simultaneously while the DVM06U3 is in normal operation to enter Parameter display mode and then pushing them both once again RAID 6 NORMAL P A parity error occurred in the host Bus during the complet...

Страница 76: ...sage Read Retry in CH Err Code x Write Retry in CH Err Code x CH 0 Drive No 0 CH 3 Drive No 3 CH 1 Drive No 1 CH 4 Drive No 4 CH 2 Drive No 2 CH 5 Drive No 5 When a drive is down an Error Sense Code w...